Date Text
2016-12-08 16:54:52FROM: RAY CARANCI, LANDSCAPE PLANNER
 PROJECT: PALM HARBOR MARINA HOTEL Z16110016
 DECEMBER 8, 2016
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. PLEASE PROVIDE A TREE MITIGATION CHART IDENTIFYING
 EXISTING TREES ON THE PROPERTY THAT WILL BE REMOVED AND
 MITIGATION PROVIDED PER SECTION 94-448.
  
 2. PLEASE PROVIDE THE PERCENTAGE OF VEGETATED AREA AND
 TREE CANOPY REQUIRED AND PROVIDED FOR QUALIFYING PLAZA
 AREAS PER SECTION 94-444.
  
 3. PLEASE PROVIDE A LANDSCAPE PLAN FOR THE ROOFTOP
 AMENITY DECK.
  
 4. PLEASE PROVIDE A COLUMN ON THE PLANT LIST SHOWING
 DROUGHT TOLERANCE LEVELS INDICATED IN WATERWISE, THE
 SOUTH FLORIDA WATER MANAGEMENT DISTRICT PLANT AND
 LANDSCAPE PRACTICES GUIDE AS SPECIFIED IN SECTION
 94-446(G). PLEASE REVISE AND RECALCULATE TO CONFIRM
 PERCENTAGES FOR POINTS CLAIMED.
  
 5. PLEASE SHOW THE TOTAL NUMBER OF PARKING SPACES
 PROVIDED ON THE SITE PLAN DATA CHART AND USE THIS
 NUMBER FOR THE CALCULATION OF LANDSCAPE AREA REQUIRED
 PER SECTION 94-443(C)(3).
  
 6. PLEASE DEMONSTRATE COMPLIANCE WITH SECTION 94-443
 (C)(4) FOR THE AMOUNT OF LANDSCAPE AREA REQUIRED IN THE
 LANDSCAPE ISLANDS PROVIDING 4 SQUARE FEET FOR EACH 100
 SQUARE FEET OF OTHER PAVED AREAS ADDITIONAL TO PARKING
 SPACES.
  
 7. PLEASE PROVIDE A LANDSCAPE TERMINAL ISLAND AND
 REQUIRED SHADE TREE FOR EACH ROW OF PARKING IN ALL
 TERMINAL ISLANDS IN PARKING AREAS PER SECTION 94-443
 (C)(3)A.
  
 8. PLEASE SHOW ALL UTILITIES INCLUDING WATER, SEWER,
 AND FPL TRANSFORMERS ON THE LANDSCAPE PLAN. ADJUST
 UTILITY LOCATIONS TO AVOID REQUIRED TREES.
  
 9. PLEASE INCLUDE A ROOT BARRIER DETAIL AND SHOW
 LOCATIONS OF ROOT BARRIERS TO PROTECT INFRASTRUCTURE
 AND TREES FROM CONFLICTS. THIS INCLUDES WATER, SEWER,
 DRAINAGE, SIDEWALKS AND CURBS, AND ANY FIELD STRUCTURES
 THAT COULD BE IMPACTED BY TREE ROOTS.
  
 10. PLEASE PROVIDE SCREENING FOR ALL GROUND MOUNTED
 EQUIPMENT AND UTILITIES.
  
 11. PLEASE PROVIDE DETAILS ON HOW THE DUMPSTER
 ENCLOSURE WILL FUNCTION AND PROVIDE A COMPLETE HEDGE
 AROUND THE THREE NON-ACCESS SIDES OF THE
 DUMPSTER/COMPACTOR ENCLOSURE.
  
 12. PLEASE PROVIDE A BUFFER REQUIREMENTS CHART LISTING
 THE REQUIRED BUFFER LENGTH CALCULATIONS AND NUMBER OF
 TREES REQUIRED AND PROVIDED FOR EACH SIDE OF THE
 PROPERTY AND LABEL THE LOCATIONS OF THE 5 FOOT REQUIRED
 BUFFERS PER SECTION 94-442(B).
  
 CONDITIONS OF APPROVAL
 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON
 THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE
 SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT
 SERVICES DEPARTMENT, PLANNING DIVISION.
  