Plan Review Notes
Plan Review Notes For Project Z16110014
Project Number Z16110014
Review Stop STORM
Sequence Number 1
Notes
Date Text
2016-12-14 01:45:48THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT
 APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP://
 WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER
 MITS-APPLICATIONS
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL:
 1. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE
 AVAILABLE AT
 HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX?.
 PLEASE REVIEW THE MAPS AND VERIFY THAT THE NEW MAPS
 WILL NOT IMPACT THE PROPOSED PROJECT.
  
 2. THE CITY COMMISSION RECENTLY PASSED A RESOLUTION
 INCREASING THE FREEBOARD REQUIREMENT TO ONE FOOT ABOVE
 BASE FLOOD ELEVATION FOR STRUCTURES IN A SPECIAL FLOOD
 HAZARD AREA.
  
 3. THE PLANS SHOW AN EXISTING DRAINAGE PIPE HEADING IN
 THE NW DIRECTION OUT OF THE PARKING LOT CATCH BASIN.
 SHOW WHERE THE PIPE ENDS.
  
 4. CHECK THE GRADING OF THE INTERFACES BETWEEN NEW AND
 EXISTING PARKING LOT DRIVE AISLES. THERE APPEARS TO BE
 AN EXISTING SPOT GRADE FOR THE EASTERN DRIVE AISLE THAT
 DOES NOT AGREE WITH THE PROPOSED M.E. ELEVATION.
  
 5. IDENTIFY THE ENTITY RESPONSIBLE TO MAINTAIN THE
 ONSITE AND MASTER DRAINAGE SYSTEMS.
  
 6. THE PROFILE OF THE EXISTING SIDEWALK ALONG THE SOUTH
 RIGHT-OF-WAY OF PALM BEACH LAKES BLVD MAY NEED TO BE
 REVISED. AT THE EAST END, THE EXISTING SIDEWALK IS
 HIGHER THAN THE PROPOSED FFE ELEVATION OF THE BUILDING.
 AT THE WEST END, THE SLOPE OF THE SIDEWALK CONNECTIONS
 BETWEEN THE PROPOSED BUILDING AND EXISTING SIDEWALK
 WILL EXCEED ADA CRITERIA. NOTE PALM BEACH LAKES BLVD IS
 MAINTAINED BY PALM BEACH COUNTY.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL
 BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT.
 THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS
 CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE
 ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS
  
 2. PROVIDE ENGINEERING CALCULATIONS SIGNED AND SEALED
 BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER FOR THE
 MINIMUM REQUIRED STORM RUNOFF WATER QUALITY TREATMENT
 AND PEAK FLOOD STAGES FOR 5-YEAR 1-DAY, 25-YEAR 3-DAY
 AND 100-YEAR 3-DAY DESIGN STORMS PER SFWMD CRITERIA.
  
 3. PROVIDE A COPY OF THE SFWMD ERP MODIFICATION FOR
 THIS PROPOSED DEVELOPMENT.
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120
 [email protected]
  