| Date |
Text |
| 2016-09-13 10:26:58 | PB 1559J |
| | 1515 SOUTH FLAGLER CONDO (A.K.A. THE MODERN PD) |
| | 1515 SOUTH FLAGLER |
| | |
| | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | |
| | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF ELEVEN |
| | (11) [IF MAJOR AMENDMENT] OR FIVE (5) [IF REMAINS MINOR |
| | AMENDMENT] PAPER COPIES AND AN ELECTRONIC COPY IN .PDF |
| | FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE |
| | RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS |
| | TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL |
| | COMMENTS. |
| | |
| | - IF THE PLAN ELEMENTS REQUIRING A MAJOR AMENDMENT |
| | REMAIN THEN THE PPRC COMMENTS SHALL BE SUFFICIENTLY |
| | ADDRESSED AND SUBMITTED TO THE PLANNING DIVISION BY 5 |
| | PM ON FRIDAY, SEPTEMBER 30, 2016, TO BE ELIGIBLE TO BE |
| | SCHEDULED FOR THE NOVEMBER 15, 2016 PLANNING BOARD |
| | MEETING. |
| | |
| | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT |
| | RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS |
| | FROM THE DATE OF THE PPRC MEETING (BY NOVEMBER 14, |
| | 2016), THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY |
| | FURTHER ACTION SHALL REQUIRE A NEW DEVELOPMENT |
| | APPLICATION. |
| | |
| | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE |
| | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($60). |
| | |
| | - IF THE CASE IS A MAJOR AMENDMENT THEN PUBLIC HEARING |
| | NOTIFICATION SIGNAGE SHALL BE POSTED IN ACCORDANCE WITH |
| | THE REQUIREMENTS OF SECTION 94-39(I)(5) OF THE ZONING |
| | AND LAND DEVELOPMENT REGULATIONS AND AN ADDITIONAL |
| | $2,916 IN APPLICATION AND ADVERTISING FEES ARE |
| | REQUIRED. YOU WILL ALSO BE RESPONSIBLE FOR MAILERS. |
| | |
| | - IF THIS CONTINUES AS A MINOR AMENDMENT, IN ACCORDANCE |
| | WITH SECTION 94-35(D)(6)A, SINCE THIS IS A NEW SITE |
| | PLAN WITHIN A PLANNED DEVELOPMENT, YOU NEED TO GET |
| | APPROVAL OF A LEVEL II SITE PLAN CONCURRENT WITH THE |
| | MINOR AMENDMENT. WHILE NO ADDITIONAL APPLICATION |
| | DOCUMENTS OR PLANS ARE REQUIRED AS THEY WOULD BE A |
| | DUPLICATION OF THE MATERIAL SUBMITTED WITH THE MINOR |
| | AMENDMENT APPLICATION, YOU ARE REQUIRED TO PAY THE |
| | APPLICATION FEE OF $1,500. |
| | |
| | 1) THE SOUTH SIDE PEDESTAL SETBACK FOR THE APPROVED |
| | MODERN RPD IS 24 FEET. THE SOUTHERN SETBACK SHOWN ON |
| | SHEET A111 IS ONLY 23 FEET 10 INCHES AND SHEET A125 IS |
| | ONLY 23 FEET. THIS NEW REDUCED SETBACK REQUIRES A MAJOR |
| | AMENDMENT APPROVAL BY THE CITY COMMISSION. |
| | |
| | 2) THE ENTRY CANOPY ON THE NORTH SIDE OF THE BUILDING |
| | IS SHOWN AT FIVE (5) FEET FROM THE NORTH PROPERTY LINE. |
| | THE NORTH SIDE SETBACK FOR THE MODERN RPD IS |
| | ESTABLISHED AT 34 FEET 10 INCHES, WITH A STRUCTURAL |
| | INTRUSION INTO THE SETBACK FOR THE NORTH SIDE TO BE A |
| | MAXIMUM OF SIX (6) FEET, WHICH REQUIRES ALL ELEMENTS ON |
| | THE NORTH SIDE OF THE BUILDING TO BE A MINIMUM OF 28 |
| | FEET 10 INCHES FROM THE NORTH PROPERTY LINE. THE |
| | CANOPY, AS SHOWN, DOES NOT CONFORM TO THE REQUIRED |
| | SETBACK AND THUS REQUIRES A NEW WAIVER APPROVAL BY THE |
| | CITY COMMISSION AS PART OF A MAJOR AMENDMENT. |
| | |
| | 3) THE BUILDING COMPARISON DRAWINGS ON SHEET A125 AND |
| | A127 SHOW DIFFERING LOCATIONS FOR THE OUTLINE OF THE |
| | EXISTING MODERN. THE A127 ELEVATION SHOWS THE TOWER |
| | BALCONIES ENCROACHING INTO THE PERMITTED SETBACKS, |
| | WHICH REQUIRES A NEW WAIVER APPROVAL BY THE CITY |
| | COMMISSION AS PART OF A MAJOR AMENDMENT. |
| | |
| | 4) THE REAR PEDESTAL SETBACK FOR THE APPROVED MODERN |
| | RPD IS 24 FEET 4 INCHES. SHEET A129 SHOWS THE NORTHWEST |
| | PORTION OF THE PEDESTAL WITH A SETBACK OF ONLY 13 FEET |
| | 6 5/8 INCHES. PLEASE NOTE THAT THE SETBACK IS MEASURED |
| | FROM THE PROPERTY LINE AT THE POINT ADJACENT TO THE |
| | SPECIFIC PORTION OF THE PEDESTAL. SINCE THE PROPERTY |
| | LINE JOGS EASTWARD NORTH OF THE STRIP OF LAND LEADING |
| | TO SOUTH OLIVE AVENUE, THE BUILDING PEDESTAL NEEDS TO |
| | SHIFT ACCORDINGLY TO MAINTAIN THE APPROVED SETBACK. THE |
| | BUILDING AS SHOWN REQUIRES A NEW WAIVER APPROVAL BY THE |
| | CITY COMMISSION AS PART OF A MAJOR AMENDMENT. |
| | |
| | 5) THE HEIGHT OF THE PEDESTAL, INCLUDING THE PARKING |
| | LIFT AND THE RAISED PLANTER (SHEET A129) IS THREE FEET |
| | HIGHER THAN THE APPROVED MODERN RPD HEIGHT OF THE |
| | PEDESTAL, WHICH IS AN INCREASE OF MORE THAN 5 PERCENT |
| | OF THE PEDESTAL HEIGHT ALONG THE WESTERN SIDE OF THE |
| | PROPERTY. THIS EXCEEDS WHAT STAFF CAN APPROVE AS PART |
| | OF A MINOR AMENDMENT. |
| | |
| | 6) PROVIDE DETAILS, TO INCLUDE ELEVATIONS OF THE |
| | PROPOSED COOLING TOWER AND ENCLOSURE AND THE |
| | TRANSFORMERS. PLEASE NOTE THAT MECHANICAL EQUIPMENT MAY |
| | ONLY ENCROACH FOUR (4) FEET INTO A REQUIRED SETBACK. |
| | BOTH OF THESE ENCROACH MORE THAN THE PERMITTED FOUR (4) |
| | FEET AND THUS, AS SHOWN, REQUIRE A NEW WAIVER APPROVAL |
| | BY THE CITY COMMISSION AS PART OF A MAJOR AMENDMENT. |
| | |
| | 7) THE APPROVED MODERN RPD INCLUDED A PUBLICLY |
| | ACCESSIBLE PASSIVE PARK WITH AN AREA OF 11,455 ALONG |
| | FLAGLER DRIVE. PLEASE SHOW THIS AREA AND ITS CONCEPTUAL |
| | DESIGN, WITH DETAILS, ON THE PROPOSED PLAN. THE |
| | PROVIDED PLANS SHOW A LESSER AREA GIVEN UP AS THE |
| | PASSIVE PARK. |
| | |
| | 8) THE SURVEY LISTS A PRIVATE ROAD EASEMENT OVER A |
| | PORTION OF THE STRIP OF LAND THAT LEADS TO SOUTH OLIVE |
| | AVENUE. PROVIDE A COPY OF THE EASEMENT SO THAT STAFF |
| | CAN VERIFY HOW THE STRIP OF LAND IS ENCUMBERED AND IF |
| | THE PROPOSED WATER METER AND BY-PASS PIPING IS |
| | PERMITTED. |
| | |
| | 9) PLEASE PROVIDE DETAILS FOR THE PROPOSED WATER METER |
| | AND BY-PASS PIPING, TO INCLUDE HOW IT LOOKS ABOVE |
| | GROUND. THE CIVIL PLAN SHOWS AN ENCROACHMENT OF THE |
| | PRIVATE ROAD EASEMENT. ADDITIONALLY, THE APPROVED |
| | MODERN RPD REQUIRES THAT THE ENTIRE 12 FOOT WIDE STRIP |
| | IS GRANTED AN ACCESS EASEMENT. |
| | |
| | 10) ARE RESIDENTS GOING TO HAVE ASSIGNED PARKING |
| | SPACES? |
| | |
| | 11) THE PLANS DO NOT INCLUDE A PARKING TABLE. THE |
| | PARKING TABLE SHALL INCLUDE THE NUMBER OF REQUIRED AND |
| | PROPOSED PARKING SPACES, ADA PARKING SPACES, GUEST |
| | SPACES AND BICYCLE SPACES. IT SHALL ALSO CLEARLY LIST |
| | THE NUMBER OF TANDEM AND LIFT SPACES. |
| | |
| | 12) PLEASE NOTE THAT THE GENERAL CITY PARKING CODE DOES |
| | NOT COUNT TANDEM (OR TRIDEM) OR LIFT PARKING SPACES AS |
| | COUNTING TOWARD MEETING REQUIRED PARKING SPACES, BUT |
| | THEY MAY BE PROVIDED AS EXTRA SPACES. THEREFORE 105 OF |
| | THE PARKING SPACES SHOWN ON THE PLAN MAY NOT BE COUNTED |
| | AS MEETING THE PARKING REQUIREMENTS WITHOUT THE CITY |
| | COMMISSION SPECIFICALLY ADDING A CONDITION THAT THESE |
| | SPACES COUNT TOWARD MEETING PARKING REQUIREMENTS |
| | (ADOPTING THE DOWNTOWN PARKING ALLOWANCE) AS PART OF A |
| | MAJOR AMENDMENT. THE EXISTING MODERN RPD APPROVAL |
| | PROVIDED 196 PARKING SPACES THAT WERE NOT TANDEM SPACES |
| | AND CLEARLY EXCLUDED THE TANDEM SPACES FROM MEETING THE |
| | PARING REQUIREMENTS. THE TABLE SHALL CLEARLY STATE THAT |
| | THE TANDEM (AND TRIDEM) AND LIFT PARKING WILL ONLY BE |
| | UTILIZED BY VALET. |
| | |
| | 13) THE DIMENSIONS OF THE PARKING SPACES/PARKING ROWS |
| | SHALL BE PROVIDED ON THE PLANS. THE DIMENSIONS SHALL |
| | INCLUDE THE DIMENSIONS FROM THE COLUMNS. |
| | |
| | 14) THE DIMENSIONS FOR ALL THE DRIVE AISLES SHALL BE |
| | SHOWN ON THE PLANS. |
| | |
| | 15) THE PLANS SHOW THE GARBAGE AND MOVING TRUCKS |
| | EXITING THE SITE VIA THE SAME ONE-WAY DRIVE AISLE WHICH |
| | THEY ENTER, JUST IN A REVERSE FLOW. FOR SAFETY REASONS |
| | THIS IS NOT PERMITTED. THE TRUCKS SHALL USE TWO CLEARLY |
| | MARKED, SEPARATE LANES. |
| | |
| | 16) THE AUTOTURN PLAN SHOWS THE TRUCKS SWINGING INTO |
| | THE OPPOSITE LANE OF TRAFFIC BEFORE ENTERING THE SITE |
| | (AND EXITING THE SITE FOR THE GARBAGE TRUCK) WHICH IS |
| | NOT PERMITTED. |
| | |
| | 17) THE AUTOTURN PLAN SHOWS THE SU-40 TRUCKS RUNNING |
| | OVER THE CURB IN A FEW LOCATIONS. THIS IS NOT |
| | PERMITTED. PLEASE CORRECT. |
| | |
| | 18) THE EASTERN MOST DRIVE WAY IS SHOWN WITH AN EGRESS |
| | ARROW; HOWEVER, ITS WIDTH AND PROXIMITY TO THE VALET |
| | ENTRANCE TO THE PARKING AREA ENCOURAGE ITS USE AS AN |
| | ENTRY POINT TO THE GARAGE. THIS EGRESS POINT SHALL BE |
| | REDESIGNED TO DISCOURAGE ENTRY TO THE GARAGE. IF IT IS |
| | LEFT IN ITS CURRENT CONFIGURATION, STAFF WILL HAVE TO |
| | COUNT IT AS AN ADDITIONAL ACCESS POINT. THIS WOULD |
| | EXCEED THE PERMITTED TWO ACCESS POINTS TO A PUBLIC |
| | RIGHT-OF-WAY, WHICH REQUIRES A CITY COMMISSION WAIVER |
| | AS A MAJOR PLANNED DEVELOPMENT AMENDMENT. |
| | |
| | 19) THERE SHALL BE AT LEAST TWO BICYCLE RACKS (FOUR |
| | BICYCLE PARKING SPACES) PROVIDED NEAR THE ENTRANCE TO |
| | THE BUILDING IN ACCORDANCE WITH SECTION 94-485(Q). |
| | |
| | 20) PLEASE DEMONSTRATE HOW THE REMAINDER OF THE |
| | REQUIRED BICYCLE PARKING SPACES (MINIMUM SIX BICYCLES) |
| | WILL MEET CITY BICYCLE PARKING SIZE REQUIREMENTS AND |
| | FIT IN THE BICYCLE STORAGE AREA. PLEASE NOTE THAT STAFF |
| | RECOMMENDS PROVIDING ENOUGH SPACE TO HOUSE MORE THAN |
| | SIX BICYCLES. |
| | |
| | 21) PLEASE PROVIDE VERIFICATION THAT THE PROPOSED PLAN |
| | WIDENS THE ARKONA COURT TRAVEL LANE TO 22 FEET ADJACENT |
| | TO THE PROPERTY AS REQUIRED BY THE APPROVED MODERN RPD |
| | PLAN. |
| | |
| | 22) SECTION 94-485(J)(1) PROHIBITS PARKING |
| | CONFIGURATIONS WHICH REQUIRE BACKING DIRECTLY ONTO A |
| | STREET, SO THE EIGHT ANGLED PARKING SPACES ARE NOT |
| | PERMITTED. THE CITY COMMISSION APPROVED 11 PARALLEL |
| | PARKING SPACES ALONG ARKONA COURT. ALTERNATIVE |
| | CONFIGURATIONS OR NUMBER OF SPACES REQUIRE APPROVAL AS |
| | A MAJOR AMENDMENT BY THE CITY COMMISSION. |
| | |
| | 23) PLEASE VERIFY WITH THE CITY'S ENGINEERING SERVICES |
| | DIVISION THAT ON-STREET PARKING SPACE NO. 11 IS A |
| | SUFFICIENT DISTANCE FROM FLAGLER DRIVE. |
| | |
| | 24) ALL REQUIRED FIRE HYDRANTS SHALL BE CLEARLY SHOWN |
| | AND LABELED ON THE SITE AND LANDSCAPE PLANS. THE |
| | PROPOSED LANDSCAPE SHALL BE ADJUSTED TO COMPLY WITH |
| | HYDRANT SETBACK REQUIREMENTS. |
| | |
| | 25) PLEASE PROVIDE LIGHTING LOCATIONS, INCLUDING POLE |
| | DETAILS, AND PHOTOMETRIC PLANS AT THIS TIME SO THAT |
| | ZONING STAFF CAN REVIEW. |
| | |
| | 26) PROVIDE CROSS SECTIONS OF THE BUFFERS SHOWING THE |
| | SPECIFIC LANDSCAPE THAT IS PROPOSED AND ANY GRADE |
| | VARIATIONS. THE ELEVATION DRAWINGS WITH ELEVATIONS DO |
| | NOT PROVIDE ENOUGH DETAIL OR ACCURATE CONDITIONS - EX. |
| | THE SOUTHERN PERIMETER SWALE. |
| | |
| | 27) PROVIDE BETTER DETAILS ON WHAT THE EXTERIOR FACADE |
| | OF THE PEDESTAL WILL LOOK LIKE FROM THE EXTERIOR |
| | PROPERTIES AND RIGHTS-OF-WAY. |
| | |
| |
Print |