| 2016-09-12 12:31:37 | PLANNING BOARD CASE NO. 1559J | | | 1515 SOUTH FLAGLER DRIVE | | | | | | - CONTACT UYEN DANG @ (561) 494-1087 | | | | | | 1. EXISTING WIDTH OF ARKONA COURT IS NOT WIDE ENOUGH | | | FOR ANGLED PARKING. REVISE DESIGN FOR PARALLEL PARKING. | | | DEPTH OF STALL SHALL BE LIMITED TO 8?. | | | 2. ARE THE WEST PARKING SPACES ON ARKONA COURT PUBLIC | | | PARKING SPACES? IF SO, IT SHOULD BE CONTAINED WITHIN | | | THE RIGHTS OF WAY. | | | 3. WHAT TYPE OF APPROACH CONTROL (STOP OR YIELD) IS | | | PROPOSED FOR THE CROSSWALK EAST WEST ON FLAGLER DRIVE? | | | THIS CROSSWALK SHOULD BE UNMARKED. CONSIDER | | | GUIDANCE FROM A STUDY PERFORMED FOR FHWA IN 2002 BY | | | ZEGEER, STEWART, AND HUANG ENTITLED "SAFETY EFFECTS OF | | | MARKED VS UNMARKED CROSSWALKS AT UNCONTROLLED | | | LOCATIONS". | | | 4. CROSSWALK SHALL BE STAMPED ASPHALT AND NOT PAVERS. A | | | MAINTENANCE AGREEMENT IS NEEDED AND SKID TESTS SHALL BE | | | PERFORMED EVERY 3 YEARS BASED ON THE PERFORMANCE | | | SPECIFICATIONS. | | | 5. AUTOTURN DRAWINGS SHOW THAT THE DRIVE AISLE NEEDED | | | TO BE TWO-WAY INSTEAD OF ONE-WAY. | | | 6. PROVIDE RESTORATION LIMITS FOR THE WATER AND SEWER | | | TAP. | | | |
| |