| 2016-09-14 08:22:33 | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL |
| | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION |
| | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE |
| | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT |
| | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT |
| | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT HTTP:// |
| | WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,-PER |
| | MITS-APPLICATIONS |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE |
| | PLAN APPROVAL: |
| | |
| | 1. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE |
| | AVAILABLE AT |
| | HTTP://MAPS.CO.PALM-BEACH.FL.US/GIS/FLOODZONES.ASPX?. |
| | PLEASE REVIEW THE MAPS AND VERIFY THAT THE NEW MAPS |
| | WILL NOT IMPACT THE PROPOSED PROJECT. |
| | |
| | 2. THE CITY COMMISSION RECENTLY PASSED A RESOLUTION |
| | INCREASING THE FREEBOARD REQUIREMENT TO ONE FOOT ABOVE |
| | BASE FLOOD ELEVATION FOR STRUCTURES IN A SPECIAL FLOOD |
| | HAZARD AREA. |
| | |
| | 3. SHOW ALL UTILITIES WITHIN ARKONA COURT RIGHT-OF-WAY |
| | BETWEEN OLIVE AVE AND FLAGLER DRIVE. |
| | |
| | 4. INDICATE IF THE MID-BLOCK STORM CONNECTION ON ARKONA |
| | COURT IS AT AN EXISTING OR A PROPOSED MANHOLE. IF AT AN |
| | EXISTING MANHOLE, VERIFY THERE IS SUFFICIENT WALL AREA |
| | TO MAKE THE CONNECTION. |
| | |
| | 5. VERIFY THERE IS SUFFICIENT WALL AREA FOR THE STORM |
| | CONNECTION TO THE EXISTING MANHOLE AT FLAGLER DRIVE. |
| | |
| | 6. STORM PIPE SIZES ARE NOT SHOWN. MINIMUM PIPE SIZE |
| | WITHIN THE RIGHT-OF-WAY IS 15? RCP. |
| | |
| | 7. VALLEY GUTTER (DROP CURB) MAY BE REQUIRED ACROSS THE |
| | ONSTREET PARKING SPACES. |
| | |
| | 8. SHOW UTILITIES, SWALES AND STORMWATER DETENTION |
| | AREAS ON THE LANDSCAPE PLANS. |
| | |
| | 9. CONTACT THE PUBLIC UTILITIES DEPARTMENT ABOUT THE |
| | NEED FOR AN EASEMENT FOR THE EXISTING FIRE HYDRANT AT |
| | SOUTHEAST CORNER OF SITE. |
| | |
| | 10. ENGINEERING PLANS WERE NOT SIGNED AND SEALED. |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO |
| | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING |
| | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. |
| | |
| | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL |
| | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. |
| | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS |
| | CAN BE DOWNLOADED AT: HTTP://WPB.ORG/DEPARTMENTS/ENGINE |
| | ERING-PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS |
| | |
| | 2. PROVIDE ENGINEERING CALCULATIONS SIGNED AND SEALED |
| | BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER |
| | INDICATING THE CHANGES TO THE ONSITE PEAK FLOOD STAGES |
| | WILL NOT EXCEED THE SFWMD PERMITTED FLOOD STAGES. |
| | |
| | 3. DETAILS SHEETS WILL NEED TO UTILIZE STANDARD CITY OF |
| | WEST PALM BEACH DETAILS, WHICH MAY BE DOWNLOADED AT HTT |
| | P://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS, |
| | -PERMITS-APPLICATIONS |
| | |
| | TRACY WARD, PE |
| | SENIOR STORMWATER ENGINEER |
| | ENGINEERING SERVICES DEPARTMENT |
| | 561-494-1120 |