Date Text
2016-11-18 10:10:14COMMENTS BELOW ARE FROM THE REVIEW OF THE 11/9/2016
 ROUTED SUBMITTAL PACKAGE.
  
 1. DRAINAGE CALCULATIONS SHOW THE 25-YEAR 3-DAY PEAK
 STAGE FOR BASIN 2 (NEW GRACE PAVILION) INCREASING FROM
 19.42 FEET NGVD (2008 ERP PERMIT) TO 19.42 FEET NGVD
 WITH THE LAKE MOVED. THIS IS LIKELY DUE TO THE
 TAILWATER CONDITIONS ON THE CONTROL STRUCTURE. THE 2008
 DRAINAGE CALCULATIONS ASSUMED A MAX TAILWATER STAGE OF
 15.0 FEET NGVD IN THE LAKE WHEREAS THE 2016 STORMWATER
 MODEL ACCOUNTS FOR THE ENTIRE 13.2 ACRE DRAINAGE AREA.
 SINCE THE TWO DRAINAGE BASINS ARE BEING MODELED
 TOGETHER, HAVE YOU CONSIDERED LOWERING THE WEIR IN THE
 EXISTING CONTROL STRUCTURE FOR BASIN 2? THIS MAY LOWER
 THE PEAK STAGE IN BASIN 2 SO THAT THE PERIMETER BERM
 WILL NOT HAVE TO BE ADJUSTED. SFWMD WOULD HAVE TO
 APPROVE CHANGES TO THE CONTROL STRUCTURE.
  
 2. DRAINAGE CALCULATIONS FOR THE BUILD OUT CONDITION ON
 THE 13.2 ACRE SITE INDICATE THE PERIMETER BERM WILL
 NEED TO BE RAISED TO ELEVATION 20.0 FEET NGVD TO
 CONTAIN THE PEAK 25-YEAR 3-DAY STORM. WILL RAISING THE
 PERIMETER BERM TO 20.0 FEET NGVD AFFECT THE STORAGE
 VOLUME IN THE SOUTHEAST DRY DETENTION AREA (DDA) (TWO
 SIDES OF DDA ABUT THE SITE PROPERTY LINE) AND WAS THIS
 TAKEN INTO ACCOUNT IN THE BUILD OUT CALCULATIONS? WITH
 THE DESIGN GRADING FOR THE ENTRANCE ROAD ON MILITARY
 TRAIL TAKE INTO CONSIDERATION THE FUTURE MINIMUM
 PERIMTER ELEVATION?
  
 3. CAN THE PROPOSED LAKE BE ENLARGED TO REDUCE THE
 FUTURE BUILD OUT PEAK STAGE?
  
 4. APPROVED SFWMD ERP PERMIT MODIFICATION TO BE
 SUBMITTED WITH THE ENGINEERING PERMIT.
  
 5. LANDSCAPE PLANS SHOW NEW TREES PLANTED ALONG THE
 OUTFALL PIPE INTO THE NEW LAKE. RECOMMEND PLANTING THE
 TREES A MINIMUM OF 5 FEET HORIZONTALLY FROM THE STORM
 PIPE.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 [email protected]
 561-494-1120
  