| Date |
Text |
| 2016-08-10 11:46:16 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, |
| | COMMENTS: |
| | |
| | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE |
| | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH |
| | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE |
| | ADDRESSED FOR PERMITTING. |
| | |
| | 2. ACCESSIBLE PARKING SPACES. THE VALET PARKING |
| | STRUCTURE WILL INCREASE THE TOTAL NUMBER OF PARKING |
| | SPACES PROVIDED AN MAY TRIGGER A REQUIREMENT FOR |
| | ADDITIONAL ACCESSIBLE PARKING SPACES. THE SITE DATA |
| | TABLE ON SITE PLAN, SHEET SP.1, STATES THAT 20 |
| | ACCESSIBLE PARKING SPACES ARE PROVIDED. HOWEVER, THEY |
| | ARE NOT SHOWN ON THE PLANS. PLEASE PROVIDE A PLAN |
| | SHOWING THE LOCATION OF THE ACCESSIBLE PARKING SPACES, |
| | INCLUDING THE VAN ACCESSIBLE PARKING SPACES. THE |
| | MINIMUM NUMBER OF ACCESSIBLE PARKING SPACES PROVIDED |
| | SHALL BE IN ACCORDANCE WITH SECTION 208.2 OF FLORIDA |
| | ACCESSIBILITY CODE. |
| | |
| | 3. DISTRIBUTION OF ACCESSIBLE PARKING. THE VALET |
| | PARKING STRUCTURE WILL INCREASE THE TOTAL NUMBER OF |
| | PARKING SPACES PROVIDED. PLEASE PROVIDE A PLAN SHOWING |
| | THE DISTRIBUTION OF THE ACCESSIBLE PARKING SPACES, |
| | INCLUDING THE VAN ACCESSIBLE PARKING SPACES. PER |
| | SECTION 208.3 OF FLORIDA ACCESSIBILITY CODE, ACCESSIBLE |
| | PARKING SPACES ARE TO BE LOCATED ON THE SHORTEST |
| | POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING TO AN |
| | ACCESSIBLE ENTRANCE FOR EACH BUILDING. THE DESIGN OF |
| | ACCESSIBLE PARKING SPACES SHALL COMPLY WITH SECTION 502 |
| | OF FLORIDA ACCESSIBILITY CODE |
| | |
| | 4. VAN ACCESSIBLE PARKING SPACES. PER SECTION 208.2.4 |
| | OF FLORIDA ACCESSIBILITY CODE, ONE IN EVERY SIX |
| | ACCESSIBLE SPACES (AT LEAST ONE) IN A PARKING |
| | STRUCTURE, SHALL BE ?VAN ACCESSIBLE? AND DESIGNED IN |
| | ACCORDANCE WITH SECTION OF 502 OF FLORIDA ACCESSIBILITY |
| | CODE (VERTICAL CLEARANCE NOT LESS THAN 98 INCHES AT |
| | SPACE AND VEHICULAR ACCESS ROUTE) |
| | |
| | 5. ACCESS AISLE FOR ACCESSIBLE PARKING SPACE ACCESS |
| | AISLES SHALL BE LOCATED SO THAT THE USER IS NOT |
| | COMPELLED TO WALK OR WHEEL BEHIND ANOTHER PARKED |
| | VEHICLE OR IN THE TRAVEL LANE. THE ACCESS AISLES SHALL |
| | ALSO COMPLY WITH THE OTHER PROVISIONS OF SECTION OF |
| | 502.3 OF FLORIDA ACCESSIBILITY CODE. |
| | |
| | 6. THE PLANS PROPOSE AN EXPANSION OF DREYFOOS HALL. THE |
| | ADDITION TO THE EXISTING BUILDING IS COVERED BY CHAPTER |
| | 11 OF THE FLORIDA EXISTING BUILDING CODE. THE HEIGHT |
| | AND/OR AREA INCREASE DUE TO THE PROPOSED ADDITION SHALL |
| | NOT INCREASE THE TOTAL BUILDING HEIGHT AND/OR AREA |
| | BEYOND THAT ALLOWED UNDER THE APPLICABLE PROVISIONS OF |
| | CHAPTER 5 OF THE FLORIDA BUILDING CODE FOR THE TYPE OF |
| | CONSTRUCTION USED. |
| | |
| | 7. PROPOSED VALET PARKING STRUCTURE, CONSTRUCTION TYPE. |
| | WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL |
| | SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS |
| | WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND |
| | OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA |
| | BUILDING CODE |
| | |
| | 8. PROPOSED VALET PARKING STRUCTURE, HORIZONTAL |
| | SEPARATION. WHEN SUBMITTED FOR BUILDING PERMIT, |
| | COMPLIANCE WITH ALL BUILDING SEPARATION, PERCENTAGE OF |
| | OPENINGS AND OPENING PROTECTIVE REQUIREMENTS OF |
| | CHAPTERS 6 AND 7 OF THE FLORIDA BUILDING CODE SHALL BE |
| | VERIFIED. |
| | |
| | 9. PROPOSED VALET PARKING STRUCTURE, VENTILATION. |
| | ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES |
| | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO |
| | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL |
| | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE |
| | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED |
| | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR |
| | OTHER APPROVED METHODS. |
| | |
| | 10. PROPOSED VALET PARKING STRUCTURE, BUILDING ADDRESS. |
| | EACH SEPARATE BUILDING SHALL HAVE A SEPARATE ADDRESS. |
| | FOR STREET ADDRESSING, CONTACT MICHAEL ORIO, GIS |
| | SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL: |
| | [email protected] |
| | |
| | 11. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS |
| | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE |
| | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED |
| | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, |
| | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND |
| | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, |
| | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. |
| | |
| | 12. ART IN PUBLIC PLACES. THIS PROJECT WILL BE SUBJECT |
| | TO ART IN PUBLIC PLACES (AIPP) ASSESSMENT. FOR ADVICE |
| | ON THE PROVISION OF PUBLIC ARTWORK IN LIEU OF THE AIPP |
| | ASSESSMENT, CONTACT SYBILLE WELTER, ART IN PUBLIC |
| | PLACES COORDINATOR, AT (561) 822-1521, OR BY EMAIL: |
| | [email protected] |
| | |
| | ROBERT BROWN |
| | BUILDING OFFICIAL |
| | TEL: 561 805 6652 |
| | EMAIL: [email protected] |
| | |
| |
Print |