Plan Review Notes
Plan Review Notes For Project Z16070018
Project Number Z16070018
Review Stop Z
Sequence Number 1
Notes
Date Text
2016-08-05 16:41:55GENERAL COMMMENTS:
  
 1.) THE SITE PLAN IS CONTINGENT UPON THE APPROVAL OF
 APPLICATIONS PB CASE NO. 1715 (ROW ABANDONMENT OF BOYD
 STREET) AND PB CASE NO. 1714 (MAJOR SUBDIVISION).
 PLEASE NOTE THAT THE SITE PLAN WILL NOT BE CONSIDERED
 FOR APPROVAL UNTIL THE APPLICANT HAS OBTAINED APPROVALS
 FOR PB 1715 AND PB 1714.
  
 2.) PLEASE NOTE THAT STAFF HAS SOME CONCERNS WITH THE
 REQUEST TO ABANDON BOYD STREET, BETWEEN WHITNEY STREET
 AND THE CSX (PB CASE NO. 1715). ALTHOUGH THIS SECTION
 OF BOYD STREET IS CURRENTLY CLOSED OFF, IT IS STILL
 FREQUENTLY UTILIZED BY PEDESTRIANS TO CROSS OVER THE
 CSX TRACKS TO THE NORTH/SOUTH SIDES OF THE STREET.
 FURTHER DISCUSSION ON THE PROPOSED ABANDONMENT AND THE
 POSSIBILITY OF PROVIDING A PEDESTRIAN CROSSING IS
 REQUIRED BETWEEN THE APPLICANT, AND STAFF FROM THE
 PLANNING DIVISION AND THE ENGINEERING SERVICES
 DEPARTMENT.
  
 3.) A TRAFFIC PERFORMANCE STANDARDS (TPS) REVIEW LETTER
 FROM THE PALM BEACH COUNTY TRAFFIC DIVISION, VERIFYING
 THAT THE PROJECT MEETS THE TPS STANDARDS OF THE COUNTY
 WILL BE REQUIRED PRIOR TO THE APPROVAL OF THIS
 APPLICATION.
  
  
 SITE PLAN:
  
 1.) THE PROPOSED 6 FT. HIGH CHAIN LINK FENCE ALONG
 WHITNEY STREET, WHICH LIES ADJACENT TO A RESIDENTIAL
 ZONING DISTRICT, IS NOT PERMITTED PURSUANT TO ZLDR S.
 94-443(A). PLEASE REPLACE THE CHAIN LINK FENCE WITH A
 PROTECTIVE SCREEN WALL THAT IS CONSTRUCTED OUT OF
 BRICK, DECORATIVE CONCRETE, OTHER DECORATIVE MASONRY,
 OR COMPARABLY DURABLE AND AESTHETIC WOOD OR METAL.
  
 2.) THE CURRENT PROPOSED LOCATION OF THE DUMPSTER
 ENCLOSURE AT THE REAR OF THE BUILDING DOES NOT SEEM TO
 BE AN APPROPRIATE LOCATION FOR SANITATION TRUCKS TO
 EASILY ACCESS. PLEASE RELOCATE THE DUMPSTER ENCLOSURE
 TO A MORE FEASIBLE LOCATION.
  
 3.) THE AREA OF THE EXISTING LOADING ZONE AND THE
 CAPABILITY OF TRUCKS TO MANEUVER WITHIN THE LOADING
 AREA HAVE BEEN MODIFIED TO ACCOMMODATE THE PROPOSED
 EXPANSION. PLEASE NOTE THAT THE CONFIGURATION OF
 LOADING INGRESS AND EGRESS, WHICH REQUIRES BACKING
 DIRECTLY ONTO A STREET FROM A LOADING SPACE IS
 PROHIBITED. DEMONSTRATE HOW THE PROPOSED LOADING AREA
 CONFIGURATION WILL NOT BACK OUT DIRECTLY ON MERCER
 AVENUE OR RECONFIGURE THE LOADING AREA FOR
 LOADING/UNLOADING SO THAT THIS REQUIREMENT IS
 ADDRESSED. [ZLDR S.94-485(J)(1)]
  
 4.) PURSUANT TO ZLDR S.94-485(Q), ONE (1) BICYCLE
 PARKING SHALL BE PROVIDED FOR EVERY 20 AUTOMOBILE
 PARKING SPACE. PLEASE IDENTIFY THE BICYCLE RACK
 LOCATION AND INCLUDE A DETAIL OF THE RACK IN THE SITE
 PLAN. ALSO INCLUDE THE BICYCLE PARKING CALCULATIONS IN
 THE SITE DATA TABULAR.
  
 5.) THE EXISTING USE ON THE PROPERTY IS CLASSIFIED AS
 "WAREHOUSING HAVING MODERATE EXTERNAL IMPACTS." PLEASE
 MAKE ALL THE NECESSARY CORRECTIONS IN THE SITE DATA
 TABULAR (INCLUDING THE PARKING CALCULATIONS) TO REFLECT
 THIS USE CLASSIFICATION IN ACCORDANCE WITH S.94-486 OF
 THE ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS).
  
 6.) ARE THERE ANY MECHANICAL EQUIPMENT (I.E. A/C UNITS,
 ETC.) PROPOSED FOR THE EXPANSION? IF SO, PROVIDE
 INFORMATION TO WHERE THE EQUIPMENT WILL BE LOCATED.
  
 7.) PLEASE MAKE THE FOLLOWING CORRECTIONS IN THE SITE
 DATA TABULAR: APPLICATION NUMBER: FSPR 16-07; TOTAL
 SITE AREA: 79,715 SQ. FT. (NOT 79,775 SQ. FT.);
 PROPOSED PARKING: 65 SPACES (NOT 67 SPACES); LOADING
 REQUIRED: 2 (NOT 1); BUILDING HEIGHT: 24' (MAX. 50');
 "LOADING REQUIRED (10' X 50')" IS NOTATED BY AN
 ASTERISK (*) - CLARIFY WHAT THE ASTERISK IS SUPPOSED TO
 MEAN.
  
 8.) PLEASE MAKE THE FOLLOWING CORRECTIONS IN THE
 DEVELOPMENT REGULATIONS TABULAR: MAXIMUM BUILDING
 HEIGHT IS 50'
  
 9.) PLEASE NOTATE IN THE SITE AND LANDSCAPING PLANS
 THAT THE EXISTING AND PROPOSED BUILDING IS A WAREHOUSE
 USE. "EXISTING BUILDING" AND "PROPOSED BUILDING" SEEMS
 INSUFFICIENT.
  
  
 LANDSCAPE PLAN:
  
 1.) THE PROPOSED EXPANSION WILL REQUIRE THE REMOVAL OF
 EXISTING TREES ON SITE. PLEASE NOTE THAT ANY EXISTING
 TREES AND/OR PALMS CANNOT BE REMOVED FROM THE PROPERTY
 WITHOUT FIRST OBTAINING A TREE ALTERATION PERMIT FROM
 THE DEVELOPMENT SERVICES DEPARTMENT ? PLANNING
 DIVISION.
  
 2.) ADDITIONAL COMMENTS ON THE LANDSCAPE PLAN TO BE
 PROVIDED BY THE CITY'S LANDSCAPE PLANNER, RAY CARANCI.
  
  
 FLOOR PLANS AND ELEVATIONS:
  
 1.) CONSIDER ADDING ARCHITECTURAL FEATURES AND
 FENESTRATION TO THE PROPOSED BUILDING EXPANSION,
 PARTICULARLY ALONG THE ELEVATIONS THAT ARE MOST VISIBLE
 FROM THE RIGHT-OF-WAYS (I.E. ALONG MERCER AVENUE AND
 ALONG THE CSX RAILROAD TRACKS).
  
 2.) PLEASE CHECK THE BUILDING ELEVATIONS IN SHEET EL
 AND MAKE CORRECTIONS WHERE NECESSARY. THERE SEEMS TO BE
 SOME INCONSISTENCIES WITH THE BUILDING ELEVATIONS
 PROVIDED.
  
 3.) FINAL PLANS SHALL BE SIGNED, DATED AND SEALED BY A
 FLORIDA REGISTERED ARCHITECT.
  
  
 LIGHTING:
  
 1.) WILL THERE BE ANY SITE LIGHTING FOR THE PROPOSED
 PROJECT? IF SO, PLEASE PROVIDE LOCATION OF THE LIGHT
 FIXTURES IN A PHOTOMETRIC PLAN.
  
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX
 (6) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 INCHES X
 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 INCHES, AND
 AN ELECTRONIC COPY OF ALL PLANS. PLEASE NOTE THAT
 CHANGES ON THE RESUBMITTED PLANS MAY RESULT IN
 ADDITIONAL COMMENTS.
  
 * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE
 ($300.00).
  
 * CONTACT PAUL GREILICH @ (561) 822-1443 IF THERE ARE
 QUESTIONS.