2016-06-09 08:58:01CITY OF WEST PALM BEACH
 ENGINEERING DEPARTMENT
 PUBLIC UTILITY COMMENTS
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. PLEASE SUBMIT SIGNED & SEALED ENGINEER/MEP WATER AND
 SEWER DEMAND CALCULATIONS (AVERAGE AND PEAK) FOR METER
 SIZING SELECTION AND SERVICE SIZING. PLEASE ALSO
 PROVIDE CALCULATION FOR FIRE FLOW DEMAND;
  
 2. PLEASE INCLUDE APPLICABLE CITY OF WEST PALM BEACH
 STANDARD WATER AND SEWER DETAILS TO THE DETAILS SHEET.
 CONTACT THE ENGINEERING SERVICES DEPARTMENT (561)
 494-1040 FOR THE LATEST REVISED DETAILS.
  
 3. PLEASE PROVIDE THE FIRE HYDRANT FLOW TEST DATA FROM
 EXISTING FIRE HYDRANT USED FOR DESIGN;
  
 4. PLEASE PROVIDE UTILITY CROSSING INFORMATION;
  
 5. PLEASE LABEL CITY UTILITY PIPE SIZE AND MATERIAL;
  
 6. PLEASE CALL OUT POINT OF SERVICE FOR WATER AND
 SEWER;
  
 7. PLEASE SHOW EXISTING VALVES FOR WATER DISTRIBUTION
 SYSTEM FOR CONSTRUCTION COORDINATION PURPOSES (SYSTEM
 SHUTDOWNS, ETC.);
  
 8. PLEASE ADD EXISTING AND/OR PROPOSED FRANCHISE
 UTILITIES (SIZE AND MATERIAL), IF ANY
  
 LAURA LE, PE
 PUBLIC UTILITIES ENGINEER
 561-494-1093
 [email protected]
  
  
2016-06-08 07:52:46CITY OF WEST PALM BEACH
 ENGINEERING DEPARTMENT
  
 THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL
 DETAILS, DESIGN CALCULATIONS AND THE POLLUTION
 PREVENTION PLAN WILL BE REVIEWED AS PART OF THE
 ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT
 APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT
 APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT
 HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE
 PLAN APPROVAL.
  
 1. PLEASE VERIFY THAT THE EXISTING ENVIRONMENTAL
 RESOURCE PERMIT INCLUDES THE IMPROVEMENT SHOWN ON THE
 PROPOSED SITE PLAN MODIFICATIONS.
  
 THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO
 ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING
 BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL.
  
 1. AN ENGINEERING DEVELOPMENT APPROVAL MODIFICATION
 WILL BE REQUIRED FROM THE ENGINEERING DIVISION OF THE
 PUBLIC WORKS DEPARTMENT.
  
 2. PLEASE COORDINATE WITH THE CITY PUBLIC UTILITIES
 ENGINEER (LAURA LE) PRIOR TO FINALIZING THE PROPOSED
 UTILITY TIE IN LOCATIONS AND CONFIGURATION.
  
 3. THE INCREASE IN SOLID WASTE YARDAGE WILL NEED TO BE
 VERIFIED AS PART OF THE FINAL DESIGN TO VERIFY THAT THE
 DESIGN INCLUDES APPROPRIATE NUMBER AND SIZE OF TRASH
 BINS.
  
 KELLY CRANFORD, P.E.
 CAPITAL IMPROVEMENT PLAN MANAGER
 [email protected]
 561-494-1098
  
 BRIAN COLLINS, P.E.
 INTERIM DIRECTOR OF ENGINEERING/CITY TRAFFIC ENGINEER
 [email protected]
 561-494-1040
  
 VINCE NOEL, PSM
 CITY SURVEYOR / REAL ESTATE SUPERVISOR
 [email protected]
 561-494-1096
  
 TRACY WARD, PE
 SENIOR STORMWATER ENGINEER
 561-494-1120
 [email protected]
  
 LAURA LE, PE
 PUBLIC UTILITIES ENGINEER
 561-494-1093
 [email protected]
  