2016-07-11 16:10:47CASE NO. ISPR 16-03
 WILHELM?S RATAN, INC.
 4701 GEORGIA AVENUE
  
 - CONTACT ERIC SCHNEIDER @ (561) 822-1446
  
 - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FIVE
 (5) PAPER COPIES AND AN ELECTRONIC COPY IN .PDF FORMAT
 OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE
 RESUBMITTED PLANS OR THE SUBMITTAL OF INFORMATION/PLANS
 TO ADDRESS THE COMMENTS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT
 RECEIVED A RESPONSE TO THE PPRC COMMENTS WITHIN 60 DAYS
 FROM THE DATE OF THE PPRC MEETING (BY SEPTEMBER 13,
 2016), THE CASE SHALL BE CONSIDERED WITHDRAWN. ANY
 FURTHER ACTION SHALL REQUIRE A NEW DEVELOPMENT
 APPLICATION.
  
 - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($200).
  
 1) PROVIDE A TRAFFIC LETTER PROVIDED BY THE PALM BEACH
 COUNTY TRAFFIC DIVISION THAT VERIFIES THE ADDITIONAL
 2,630 SQUARE FEET MEETS THE COUNTY TRAFFIC PERFORMANCE
 STANDARDS.
  
 2) PROVIDE THE FPL LETTER CONFIRMING THAT THE PROPOSED
 PROJECT DOES NOT ENCROACH INTO THEIR EASEMENTS OR
 OTHERWISE INTERFERE WITH THE PROVISIONS OF THEIR
 SERVICES.
  
 3) THE SCALE ON THE SITE PLAN IS INCORRECT. IT SHOULD
 BE 1 INCH = 10 FEET.
  
 4) PROVIDE THE DIMENSIONS/SQUARE FOOTAGE OF THE
 EXISTING CANOPY AREA AND THE CONCRETE CARPORT AREA.
 THESE ARE CONSIDERED BUILDINGS FOR THE PURPOSES OF LOT
 COVERAGE AND OPEN SPACE CALCULATIONS.
  
 5) STAFF CALCULATIONS SHOW THAT THE PROPOSED ADDITION
 WILL RESULT IN LOT COVERAGE OF 66.2% (EXITING BUILDING,
 EXISTING CARPORT PLUS PROPOSED ADDITION OF 6,590 SF)
 WITH THE OPEN SPACE ONLY AT 33.8%. THE SITE SHALL HAVE
 A MAXIMUM OF 60% COVERAGE BY BUILDINGS AND A MINIMUM OF
 40% OPEN SPACE.
  
 6) THE AMOUNT OF EXISTING AND PROPOSED PERVIOUS
 AREA/LANDSCAPE IS NOT PROVIDED ON THE DATE TABLE.
  
 7) THE EXPANSION OF THE BUILDING REQUIRES THAT THE
 SOUTH PROPERTY LINE MEETS THE LANDSCAPE BUFFER
 REQUIREMENT.
  
 8) THE CITY DOES NOT PERMIT TEMPORARY BUILDINGS, SO THE
 STORAGE CONTAINER WHICH IS BEING USED AS A BUILDING
 SHALL BE REMOVED FROM THE SITE.
  
 9) PROVIDE THE FLOOR PLAN FOR THE SECOND STORY.
  
 10) THE JUSTIFICATION STATEMENT STATES THAT THE USE FOR
 THE NEW ADDITIONS WILL BE STORAGE. THREE PARKING
 SPACES, ONE OF WHICH IS ADA COMPLIANT, ARE REQUIRED FOR
 THE BUILDING EXPANSION OF 2,630 SQUARE FEET. CODE
 COMPLIANT PARKING IS NOT SHOWN ON THE PLANS. PLEASE
 NOTE THAT THE CITY'S ENGINEERING SERVICES DIVISION
 DETERMINES IF THERE ARE ADEQUATE DIMENSIONS FOR
 ON-STREET PARKING. THE VACANT LOT TO THE WEST IS
 RESIDENTIALLY ZONED AND MAY NOT BE USED FOR PARKING
 UNLESS A CLASS B SPECIAL USE PERMIT IS APPROVED BY THE
 ZONING BOARD OF APPEALS.
  
 11) THERE SHALL BE AT LEAST ONE BICYCLE PARKING SPACE
 PROVIDED ON THE SITE MEETING THE REQUIREMENTS OF
 SECTION 94-485(Q) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
 12) THE ADDITIONAL SQUARE FOOTAGE REQUIRES THE
 PROVISION OF ONE 10 FOOT BY 25 FOOT LOADING SPACE
 ON-SITE IN ACCORDANCE WITH SECTION 94-485(P) OF THE
 ZONING AND LAND DEVELOPMENT REGULATIONS.
  
 13) PLEASE REMEMBER THAT ALL VEHICULAR MOVEMENT AND
 MANEUVERING THAT MAY BE REQUIRED TO UTILIZE OFF-STREET
 PARKING FACILITIES SHALL BE RETAINED ON-SITE. PUBLIC
 RIGHTS-OF-WAY SHALL NOT BE UTILIZED TO ALLOW OR ENHANCE
 MOVEMENT OR MANEUVERING.
  
 14) THE SITE DATE TABLE SHALL BE UPDATED TO REFLECT THE
 PARKING AND BICYCLE PARKING REQUIREMENTS.
  
 15) THE DUMPSTER SHALL BE IN AN ENCLOSURE MEETING THE
 REQUIREMENTS OF SECTION 94-444(B) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS.
  
 16) STAFF NOTED ON THE SITE VISIT THAT NOT ALL THE
 OUTDOOR STORAGE OF GOODS, MERCHANDISE AND MATERIALS IS
 ENCLOSED ON ALL SIDES BY A WALL OF ADEQUATE HEIGHT
 CONSTRUCTED OF BRICK, DECORATIVE CONCRETE, OTHER
 DECORATIVE MASONRY, OR COMPARABLY DURABLE WOOD OR STEEL
 AS REQUIRED BY SECTION 94-444(C) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS.
  
 17) THE PLANS SHALL CLEARLY SHOW ALL THE CURB CUTS.
  
 18) THE SITE PLAN SHALL SHOW THE DOOR LOCATIONS FOR THE
 NEW BUILDING.
  
 19) THE SITE PLAN FAILS TO SHOW THE EXHAUST FAN ON THE
 WEST SIDE OF THE BUILDING OR THE BOLLARD WITHIN THE
 EAST DRIVEWAY.
  
 20) PLEASE CHECK YOUR WINDOW LABELS - THEY SHOULD BE
 "SINGLE" HUNG.
  