2016-03-08 15:34:411. PROPOSED PROJECT DOES NOT COMPLY WITH CURRENT
 COMPREHENSIVE PLAN AND ZLRDRS. A CODE AMENDMENT WILL BE
 NECESSARY TO ALLOW A 7-STORY BUILDING ON THE SITE.
 - ICD-5 HAS A MAXIMUM HEIGHT OF 5-STORIES. PROPOSED
 BUILDING EXCEED HEIGHT PERMITTED.
 2. A PORTE COCHERE IS NOT PERMITTED ALONG A PRIMARY
 STREET SUCH AS ROSEMARY AVENUE WITHIN ICD .
 3. SIDEWALK AROUND THE ENTIRE PROJECT IS RECOMMENDED TO
 BE AT LEAST 12 FEET.
 4. FURTHER DISCUSSION IS NECESSARY TO DETERMINE THE
 DESIRABLE SECTION FOR THE PROPOSED 4TH STREET. STAFF
 RECOMMENDS 11? TRAVEL LANES, AND 8? ON-STREET PARKING
 (COUNTING THE GUTTER).
 5. PLEASE INDICATE THE ALIGNMENT OF THE PROPOSED 4TH
 STREET IN RELATION TO THE EXISTING 4TH STREET WEST OF
 ROSEMARY AVENUE.
 6. IF THE FIRST FLOOR SPACES ALONG ROSEMARY AVE ARE
 INTENDED FOR RETAIL USES (STORES OR RESTAURANTS) THE
 WIDE LANDSCAPE AREA IS NOT APPROPRIATE.
 7. STREET TREES SHALL BE PLANTED ALONG 3RD STREET ON
 TREE GRATES ADJACENT TO THE CURB (30? SEPARATION).
 8. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE
 WITH THE BLANK WALL REGULATION.
 9. TREE GRATES SHALL BE 4? BY 4?.
 10. PLEASE INDICATE THE PARKING RAMP PROPOSED SLOPE
 (SEC 94-111 (Q)(2) ? NON-PARKING RAMP SLOPE HIGHER THAN
 14% REQUIRES A BREAK-OVER TRANSITION).
 11. ALL DRIVEWAY SHALL BE MAINTAINED AT THE ADJACENT
 SIDEWALK LEVEL.
 12. PLEASE INDICATE HOW IS THE GARBAGE PICK-UP
 OPERATION (CIRCULATION, STAGING, PRIVATE OR PUBLIC).
 PLEASE PROVIDE AUTO TURN FOR THE LOADING AREAS.
 13. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE
 WITH PLANAR BREAK REGULATIONS.
 14. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE
 WITH TRANSPARENCY REGULATIONS.
  
 ADDITIONAL COMMENTS:
 15. SURVEY SHALL INCLUDE MEASUREMENTS OF THE EXISTING
 SIDEWALKS, AND ROW INCLUDING SIDEWALK ACROSS THE STREET
 UP TO THE FACE OF BUILDINGS.
 16. PLEASE ADJUST THE SITE SQUARE FOOTAGE TO REFLECT
 THE SURVEY INFORMATION (1.13 AC= 49,223 SF)
 17. THE SITE PLAN DRAWING SHALL INCLUDE THE ADJACENT
 BUILDINGS AND STREET, INCLUDING THE BUILDINGS ACROSS
 THE STREET , AND SHOW THE PROJECT INSERTED IN THE
 CONTEXT.
 18. PLEASE PROVIDE ELECTRONIC DRAWINGS (DXF OR CADD) TO
 ALLOW THE MEASUREMENT OF THE FAR AREA INDICATED IN
 SHEET A0.06.
 19. PLEASE INCLUDE PROPERTY LINES AND SETBACK LINES IN
 ALL FLOOR PLANS AND ELEVATIONS.
 20. COLORED ELEVATIONS (ALL FACADES) SHALL INCLUDE CALL
 OUT MATERIALS AND REFERENCE PICTURES OF PROPOSED
 MATERIALS (INDICATE SCALE). FACADES SHALL INCLUDE
 ADJACENT BUILDINGS (INCLUDING ACROSS THE STREET) TO
 SHOW THE PROJECT IN ITS CONTEXT.
  