| 2016-03-09 12:56:04 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, |
| | COMMENTS: |
| | |
| | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE |
| | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH |
| | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE |
| | ADDRESSED FOR PERMITTING. |
| | |
| | 2. SHEET A-1.-00 STATES THAT T3 ACCESSIBLE PARKING |
| | SPACES WILL BE PROVIDED. HOWEVER, THE ONLY ACCESSIBLE |
| | PARKING SPACES SHOWN ON THE PLANS ARE THE TWO ON SHEET |
| | A-2.00, GROUND FLOOR PLAN. THE MINIMUM NUMBER OF |
| | ACCESSIBLE PARKING SPACES PROVIDED SHALL BE IN |
| | ACCORDANCE WITH SECTION 208.2 OF FLORIDA ACCESSIBILITY |
| | CODE. |
| | |
| | 3. WHEN THE REQUIRED ACCESSIBLE PARKING SPACES ARE |
| | SHOWN, PER SECTION 208.3 OF FLORIDA ACCESSIBILITY CODE, |
| | ACCESSIBLE PARKING SPACES ARE TO BE LOCATED ON THE |
| | SHORTEST POSSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING |
| | TO AN ACCESSIBLE ENTRANCE FOR EACH BUILDING. THE DESIGN |
| | OF ACCESSIBLE PARKING SPACES SHALL COMPLY WITH SECTION |
| | 502 OF FLORIDA ACCESSIBILITY CODE |
| | |
| | 4. WHEN THE REQUIRED ACCESSIBLE PARKING SPACES ARE |
| | SHOWN, ACCESSIBLE PARKING SPACE ACCESS AISLES SHALL BE |
| | LOCATED SO THAT THE USER IS NOT COMPELLED TO WALK OR |
| | WHEEL BEHIND ANOTHER PARKED VEHICLE OR IN THE TRAVEL |
| | LANE. THE ACCESS AISLES SHALL ALSO COMPLY WITH THE |
| | OTHER PROVISIONS OF SECTION OF 502.3 OF FLORIDA |
| | ACCESSIBILITY CODE. |
| | |
| | 5. WHEN SUBMITTED FOR BUILDING PERMIT, THE PLANS SHALL |
| | SHOW THAT THE TYPE OF CONSTRUCTION FOR THE BUILDINGS |
| | WILL BE IN ACCORDANCE WITH THE HEIGHT, AREA AND |
| | OCCUPANCY LIMITATIONS IN CHAPTER 5 OF THE FLORIDA |
| | BUILDING CODE |
| | |
| | 6. WHEN SUBMITTED FOR BUILDING PERMIT, COMPLIANCE WITH |
| | ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS AND |
| | OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 OF |
| | THE FLORIDA BUILDING CODE SHALL BE VERIFIED. |
| | |
| | 7. ENCLOSED PARKING GARAGES. IF THE PARKING GARAGE DOES |
| | NOT HAVE WALL OPENINGS, OR SUFFICIENT WALL OPENINGS TO |
| | MEET THE DEFINITION OF AN OPEN PARKING GARAGE, IT WILL |
| | BE CONSIDERED AN ENCLOSED PARKING GARAGE AND MUST HAVE |
| | EXHAUST SYSTEMS. THE EXHAUST SYSTEMS SHALL BE DESIGNED |
| | TO MINIMIZE NOISE LEVELS USING INLINE FAN SILENCERS OR |
| | OTHER APPROVED METHODS. |
| | |
| | 8. SEPARATE PERMITS REQUIRED. ALL APPLICABLE PERMITS |
| | AND SUB-PERMITS MUST BE OBTAINED BEFORE COMMENCING THE |
| | WORK. SEPARATE PERMITS, PLANS AND FEES, ARE REQUIRED |
| | FOR SIGNS, SWIMMING POOLS AND SPAS, GAS SYSTEMS, |
| | GENERATORS, FIRE ALARM SYSTEMS, FIRE SPRINKLER AND |
| | OTHER FIRE SUPPRESSION SYSTEMS, GREASE INTERCEPTORS, |
| | SITE LIGHTING, SITE LANDSCAPE, SITE IRRIGATION, ETC. |
| | |
| | 9. EACH SEPARATE BUILDING SHALL HAVE A SEPARATE |
| | ADDRESS. FOR STREET ADDRESSING, CONTACT MICHAEL ORIO, |
| | GIS SUPPORT SPECIALIST, AT (561) 494 1080, OR BY EMAIL: |
| | [email protected] |
| | |
| | 10. THIS PROJECT WILL BE SUBJECT TO ART IN PUBLIC |
| | PLACES (AIPP) ASSESSMENT. FOR ADVICE ON THE PROVISION |
| | OF PUBLIC ARTWORK IN LIEU OF THE AIPP ASSESSMENT, |
| | CONTACT SYBILLE WELTER, ART IN PUBLIC PLACES |
| | COORDINATOR, AT (561) 822-1521, OR BY EMAIL: |
| | [email protected] |
| | |
| | ROBERT BROWN |
| | BUILDING OFFICIAL |
| | TEL: 561 805 6652 |
| | EMAIL: [email protected] |
| | |
| |
Print |