Plan Review Notes
Plan Review Notes For Project Z16020011
Project Number Z16020011
Review Stop Z
Sequence Number 2
Notes
Date Text
2016-10-11 11:54:17**ZONING**
  
 GENERAL COMMENTS:
 1.) UTILITY LETTERS ARE REQUIRED FROM AT&T AND FPL.
  
 SITE PLAN COMMENTS:
 1.) THE DUMPSTER LOCATION WILL REQUIRE AN APPROVAL FROM
 PUBLIC WORKS.
  
 2.) THE DEPTH OF THE ENCLOSURE (13'8") AND THE DEPTH OF
 THE SPACE/STALL FOR THE ENCLOSURE (8.5') ARE NOT
 CONSISTENT. PROVIDE THE CLEAR DIMENSIONS FOR THE
 ENCLOSURE SPACE.
  
 3.) PROVIDE THE CLEAR DIMENSIONS FOR THE ANGULAR
 PARKING ON THE NORTHWEST SIDE OF THE BUILDING AS WELL
 AS THE TANDEM PARKING ON THE SOUTH SIDE OF THE BUILDING
 AND THE NORTHERLY PORTION OF THE PROPERTY. (SEE ANGULAR
 PARKING STANDARD DIMENSIONS IN SEC 94-485, FIGURE
 XV-2).
  
 4.) SITE PLAN SHEET SP-1 OF 1 HAS FRONT SETBACKS ON
 FLAGLER AS 32', BUT ON THE ARCHITECTURAL SITE PLAN
 SHEET A-101 HAS A FRONT SETBACK OF 25'. PLEASE MAKE
 CONSISTENT.
  
 5.) ACCESS TO STREETS SEC 94-313(1) (A) - RESIDENTIAL
 DEVELOPMENTS WITH 3-75 UNITS ARE PERMITTED TO HAVE ONE
 (1) ACCESS POINT ONTO EACH RIGHT-OF-WAY. ONE-WAY
 CURBCUT CAN BE 10'?.
  
 6.) HOW WILL GUEST GAIN ACCESS TO GATES? HOW WILL THEY
 MANEUVER OUT OF DEVELOPMENT IF THEY ARE NOT LET IN?
  
 7.) FIRE DEPARTMENT WILL REQUIRE 20' ACCESS LANE.
  
 8.) WHO WILL USE THE OBSERVATION DECK? HOW WILL IT BE
 ACCESSED?
  
 9.) PLEASE SHOW OBSERVATION DECK ON THE ELEVATION
 DRAWINGS.
  
 10.) PLEASE SHOW THE OVERHANG FOR STAIRS ON SITE PLAN
 AND ARCHITECTURAL DRAWINGS.
  
 11.) PLEASE SHOW THE CROSS-SECTION OF GRADE AND
 RETAINER WALL.
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 *PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 *WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF TEN
 (10) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 INCHES X
 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 INCHES, AND
 AN ELECTRONIC COPY OF ALL PLANS. PLEASE NOTE THAT
 CHANGES ON RESUBMITTED PLANS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 *PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF
 PREVIOUSLTY-ISSUED COMMENTS CONTINUE TO NOT BE
 SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE ASSESSED
 A RESUBMITTAL FEE. SUCH FEE WILL BE 20 PERCENT OF THE
 ORIGINAL APPLICATION FEE ($300.00).
  
 *CONTACT ALANA WOOTEN @ 561-822-1449 OR AT
 [email protected] IF THERE ARE ANY QUESTIONS.
  