2016-12-09 14:25:111. NOT SATISFIED- PROPOSED PROJECT DOES NOT COMPLY WITH
 THE MINIMUM SIZE OF A DWELLING UNIT OR THE CUMULATIVE
 AVERAGE SIZE OF A DWELLING UNIT AS PRESCRIBED BY SEC
 94-109.
 2. SATISFIED- PLEASE CORRECT CALCULATIONS FOR ACTIVE
 USES ALONG BANYAN BOULEVARD. PARKING ENTRANCES,
 MECHANICAL SPACES AND STORAGE ARE NOT CONSIDERED ACTIVE
 USES (SHEET A0.01).
 3. SATISFIED - PROPOSED PUBLIC OPEN SPACE DOES NOT
 COMPLY WITH THE MINIMUM DIMENSIONS FOR A POS (ONE SIDE
 NO MORE THAN 5 TIMES THE OTHER SIDE).
 4. NOT SATISFIED, PARKING RAMPS SHALL NOT EXCEED 6%
 SLOPE- PLEASE INDICATE THE PARKING RAMP PROPOSED SLOPE
 (SEC 94-111 (Q)(2) ? NON-PARKING RAMP SLOPE HIGHER THAN
 14% REQUIRES A BREAK-OVER TRANSITION).
 5. SATISFIED -A 20' SIDE SETBACK IS REQUIRED ABOVE THE
 5TH STORY.
 6. NOT SATISFIED, PLEASE PROVIDE INFORMATION TO CONFIRM
 THAT NO PORTION OF ANY FACADE GREATER THAN 20% OF THE
 ENTIRE FACADE ELEVATION IS ABSENT OFF FENESTRATION AND
 ABSENT OF A PLANAR BREAK OF AT LEAST TWO FEET IN DEPTH.
 PLEASE EXPLAIN THE ARCHITECTURAL TREATMENT PROVIDED FOR
 THE PARKING GARAGE ELEVATION TO DETERMINE IF THAT
 COMPLIES WITH BLANK WALL REGULATIONS- BLANK WALLS ARE
 NOT PERMITTED.
 7. SATISFIED- PROPOSED CONVENIENCE STORE WILL NOT BE
 ALLOWED TO SALE ALCOHOL (BEER, WINE OR HARD LIQUOR).
 8. SATISFIED- PLEASE INDICATE THE TREATMENT OF THE
 GARAGE ROOFTOP THAT WILL NOT BE UTILIZED FOR ROOF
 GARDEN.
 9. NOT SATISFIED, PLEASE PROVIDE A DESIGNED DETAIL TO
 SHOW THE SIDEWALK LEVEL MAINTAINED AT THE DRIVEWAY. DO
 NOT USE WPB DETAIL GD-7- DRIVEWAY SHALL BE MAINTAINED
 AT THE ADJACENT SIDEWALK LEVEL.
 10. NOT SATISFIED, AUTO TURN NOT INCLUDED IN SET
 SUBMITTED. FURTHER DISCUSSION WITH SANITATION
 DEPARTMENT NEEDED- PLEASE INDICATE HOW IS THE GARBAGE
 PICK-UP OPERATION (CIRCULATION, STAGING, PRIVATE OR
 PUBLIC). PLEASE PROVIDE AUTO TURN FOR THE LOADING
 AREAS.
 11. NOT SATISFIED, VARIANCE REQUEST MENTIONED ON
 RESPONSE LETTER. PLEASE NOTE THAT PLANAR BREAK SHALL
 OCCUR FOR THE ENTIRE HEIGHT OF THE PODIUM- PLEASE
 PROVIDE INFORMATION TO CONFIRM COMPLIANCE WITH PLANAR
 BREAK REGULATIONS.
 12. SATISFIED- PLEASE PROVIDE INFORMATION TO CONFIRM
 COMPLIANCE WITH TRANSPARENCY REGULATIONS.
 NEW COMMENTS BASED ON 11/7/16 SUBMITTAL:
 13. DRIVE AISLE SHALL BE MINIMUM 24' IN WIDTH WHEN 90
 DEGREE PARKING IS PROVIDED.
 14. PLEASE PROVIDE ADDITIONAL INFORMATION FOR THE
 TREATMENT OF THE FIRST FLOOR, INCLUDE MATERIALS. SOME
 CONCERN ABOUT THE EXCESIVE GLASS AS SOME OF THE USES
 ARE NOT CONDUCIVE TO SUCH AMOUNT OF TRANSPARENCY (YOGA
 ROOM OR SCREENING ROOM).
 15. PLEASE PROVIDE MORE DETAILS ON FACADE, CROSS
 SECTION OF FACADE TO DEMONSTRATE THE DEPTH OF THE
 WINDOWS INDICATED ON THE RENDERINGS, THE MATERIALS
 PROPOSED ETC. ARE THE STAIRS AT THE SW CORNER OF
 BUILDING PROPOSED TO HAVE THE SAME TREATMENT OF A
 RESIDENTIAL UNIT?
 16. BUILDING EXCEEDS MAXIMUM BUILDING FOOTPRINT ON 4TH
 FLOOR (MAX ALLOWED=60%; PROPOSED 79%)
 17. MINIMUM SETBACK AREA (16') CANNOT BE ENCLOSED AS A
 PRIVATE PATIO.
 18. BACK FLOW PREVENTORS SHALL BE SCREENED FROM STREET.
 19. PLEASE PROVIDE A HARDSCAPE DRAWINGS WITH DETAIL ON
 PROPOSED MATERIALS, LIGHTING PLAN AND ANY OTHER STREET
 FURNITURE PROPOSED.
 20. PLEASE PROVIDE A TABLE WITH THE SIZE OF EACH UNIT
 AND THE AVERAGE FOR BUILDING.
 21. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE
 WITH BICYCLE PARKING REGULATION (1/15 REQUIRED SPACES).
 22. FLOOR PLANS FOR LEVEL 10 AND 12 ARE MISSING FROM
 SUBMITTED SET.
 23. STAFF RECOMMENDS THE BUIDLING TO RESPOND TO THE
 SMALLER SCALE OF CLEMATIS STREET WITH SOME STEP DOWN AT
 THE SW CORNER OF THE BUILDING.
 24. THE PROPOSED USES ON THE FIRST FLOOR RESULT IN A
 SINGLE ENTRANCE TO THE BUIDLING. STAFF SUGGESTS THE
 INTRODUCTION OF ADDITIONAL ACTIVE USES AT GROUND LEVEL
 TO CONTRIBUTE TO THE PEDESTRIAN ENVIRONMENT AND
 ACTIVITY (MORE ENTRANCES).
 ADDITIONAL COMMENTS:
 1. NOT SATISFIED -PROJECT IS UTILIZING THE TDR PROGRAM,
 THEREFORE DAC SPECIAL REVIEW WILL BE REQUIRED.
 2. NOT SATISFIED - SURVEY SHALL INCLUDE MEASUREMENTS OF
 THE EXISTING SIDEWALKS, AND ROW INCLUDING SIDEWALK
 ACROSS THE STREET AND FACE OF BUILDINGS.
 3. SATISFIED - THE SITE PLAN DRAWING SHALL INCLUDE THE
 ADJACENT BUILDINGS AND STREET, INCLUDING THE BUILDINGS
 ACROSS THE STREET , AND SHOW THE PROJECT INSERTED IN
 THE CONTEXT.
 4. SATISFIED - PLEASE PROVIDE ELECTRONIC DRAWINGS (DXF
 OR CADD) TO ALLOW THE MEASUREMENT OF THE FAR AREA
 INDICATED IN SHEET A0.06.
 5. SATISFIED- PLEASE INCLUDE PROPERTY LINES AND SETBACK
 LINES IN ALL FLOOR PLANS AND ELEVATIONS.
 6. SATISFIED- PLEASE PROVIDE COLORED ELEVATIONS (ALL
 FACADES) WITH CALL OUT MATERIALS AND REFERENCE PICTURES
 OF PROPOSED MATERIALS (INDICATE SCALE). FACADES SHALL
 INCLUDE ADJACENT BUILDINGS TO SHOW THE PROJECT IN ITS
 CONTEXT.
 7. SATISFIED- RENDERINGS SHALL BE AN ACCURATE
 REFLECTION OF THE SURROUNDING AREA, ACCOUNTING FOR
 EXISTING STREET DIMENSIONS AND SURROUNDING BUILDINGS.
 8. SATISFIED - FIRST FLOOR PLAN SHALL INDICATE THE
 LOCATION OF PROPOSED DOORS AND WINDOWS.