| 2016-03-08 12:00:06 | 1. PROPOSED PROJECT DOES NOT COMPLY WITH THE MINIMUM |
| | SIZE OF A DWELLING UNIT OR THE CUMULATIVE AVERAGE SIZE |
| | OF A DWELLING UNIT AS PRESCRIBED BY SEC 94-109. |
| | 2. PLEASE CORRECT CALCULATIONS FOR ACTIVE USES ALONG |
| | BANYAN BOULEVARD. PARKING ENTRANCES, MECHANICAL SPACES |
| | AND STORAGE ARE NOT CONSIDERED ACTIVE USES (SHEET |
| | A0.01). |
| | 3. PROPOSED PUBLIC OPEN SPACE DOES NOT COMPLY WITH THE |
| | MINIMUM DIMENSIONS FOR A POS (ONE SIDE NO MORE THAN 5 |
| | TIMES THE OTHER SIDE). |
| | 4. PLEASE INDICATE THE PARKING RAMP PROPOSED SLOPE (SEC |
| | 94-111 (Q)(2) ? NON-PARKING RAMP SLOPE HIGHER THAN 14% |
| | REQUIRES A BREAK-OVER TRANSITION). |
| | 5. A 20? SIDE SETBACK IS REQUIRED ABOVE THE 5TH STORY. |
| | 6. BLANK WALLS ARE NOT PERMITTED. |
| | 7. PROPOSED CONVENIENCE STORE WILL NOT BE ALLOWED TO |
| | SALE ALCOHOL (BEER, WINE OR HARD LIQUOR). |
| | 8. PLEASE INDICATE THE TREATMENT OF THE GARAGE ROOFTOP |
| | THAT WILL NOT BE UTILIZED FOR ROOF GARDEN. |
| | 9. DRIVEWAY SHALL BE MAINTAINED AT THE ADJACENT |
| | SIDEWALK LEVEL. |
| | 10. PLEASE INDICATE HOW IS THE GARBAGE PICK-UP |
| | OPERATION (CIRCULATION, STAGING, PRIVATE OR PUBLIC). |
| | PLEASE PROVIDE AUTO TURN FOR THE LOADING AREAS. |
| | 11. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE |
| | WITH PLANAR BREAK REGULATIONS. |
| | 12. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE |
| | WITH TRANSPARENCY REGULATIONS. |
| | |
| | ADDITIONAL COMMENTS: |
| | 1. PROJECT IS UTILIZING THE TDR PROGRAM, THEREFORE DAC |
| | SPECIAL REVIEW WILL BE REQUIRED. |
| | 2. SURVEY SHALL INCLUDE MEASUREMENTS OF THE EXISTING |
| | SIDEWALKS, AND ROW INCLUDING SIDEWALK ACROSS THE STREET |
| | AND FACE OF BUILDINGS. |
| | 3. THE SITE PLAN DRAWING SHALL INCLUDE THE ADJACENT |
| | BUILDINGS AND STREET, INCLUDING THE BUILDINGS ACROSS |
| | THE STREET , AND SHOW THE PROJECT INSERTED IN THE |
| | CONTEXT. |
| | 4. PLEASE PROVIDE ELECTRONIC DRAWINGS (DXF OR CADD) TO |
| | ALLOW THE MEASUREMENT OF THE FAR AREA INDICATED IN |
| | SHEET A0.06. |
| | 5. PLEASE INCLUDE PROPERTY LINES AND SETBACK LINES IN |
| | ALL FLOOR PLANS AND ELEVATIONS. |
| | 6. PLEASE PROVIDE COLORED ELEVATIONS (ALL FACADES) WITH |
| | CALL OUT MATERIALS AND REFERENCE PICTURES OF PROPOSED |
| | MATERIALS (INDICATE SCALE). FACADES SHALL INCLUDE |
| | ADJACENT BUILDINGS TO SHOW THE PROJECT IN ITS CONTEXT. |
| | 7. RENDERINGS SHALL BE AN ACCURATE REFLECTION OF THE |
| | SURROUNDING AREA, ACCOUNTING FOR EXISTING STREET |
| | DIMENSIONS AND SURROUNDING BUILDINGS. |
| | 8. FIRST FLOOR PLAN SHALL INDICATE THE LOCATION OF |
| | PROPOSED DOORS AND WINDOWS. |
| | |
| |