| Date |
Text |
| 2016-05-10 12:16:24 | FROM: RAY CARANCI, LANDSCAPE PLANNER |
| | PROJECT: 3111 S DIXIE Z15120017 |
| | MAY 9, 2016 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. THE PERVIOUS AREA ONLY EXCEEDS THE MINIMUM REQUIRED |
| | BY 433 SQUARE FEET. THE STABILIZED EMERGENCY ACCESS |
| | AREA IS COUNTED AS 100% PERVIOUS. PLEASE PROVIDE A |
| | DETAIL OF THE STABILIZED SYSTEM AND DEDUCT THE AREA |
| | THAT IS NOT PERVIOUS. PLEASE BE AWARE THAT ANY CHANGES |
| | TO THE DESIGN IN THE FUTURE MUST ACCOUNT FOR ANY |
| | PERVIOUS AREA ALTERATIONS, AND ASSURE COMPLIANCE WITH |
| | THE MINIMUM REQUIREMENT. |
| | |
| | 2. THE WAIVER REQUEST FOR THE DIXIE BUFFER SHOULD |
| | INDICATE A 10 FOOT BUFFER IS REQUIRED. PLEASE CORRECT |
| | THE CHART ON FSP-1. |
| | |
| | 3. THE WAIVER REQUEST FOR THE SHADE TREE REDUCTION |
| | SHOULD INDICATE THE CORRECT NUMBER OF TREES. LANDSCAPE |
| | DATA CHART SHEET LP-1, WAIVER CHART ON FSP-1, AND |
| | JUSTIFICATION STATEMENT ARE NOT CONSISTENT WITH THE |
| | QUANTITY. |
| | |
| | 4. A LANDSCAPE BUFFER OF 5 FEET IN WIDTH IS SHOWN ON |
| | THE PLAN ALONG THE WEST PROPERTY LINE, YET WAIVER |
| | REQUEST #6 STILL INDICATES A REQUEST FOR A ZERO BUFFER |
| | WIDTH. WAIVER MAY NO LONGER BE NEEDED. THE PALMS MAY BE |
| | SUBSTITUTED FOR THE REQUIRED TREES IF THE TOTAL NUMBER |
| | OF PALMS SUBSTITUTED FOR SHADE TREES ON SITE DOES NOT |
| | EXCEED 35%. |
| | |
| | 5. THE CALCULATIONS PROVIDED FOR THE PARKING LOT |
| | LANDSCAPE REQUIREMENTS DO NOT REPRESENT AREAS PROVIDED |
| | IN THE PARKING AREAS AS REQUIRED. PLEASE REVISE TO SHOW |
| | HOW THE LANDSCAPE AREAS WITHIN THE PARKING LOT COMPLY |
| | WITH SECTION 94-443(C) 3 AND 4. |
| | |
| | 6. PLEASE PROVIDE A LANDSCAPE PLAN FOR THE ROOFTOP |
| | AMENITY DECK. THIS IS MATERIAL IN CONSIDERING THE TRUE |
| | QUANTITY OF WAIVER REQUEST #8, AND FOR TREE MITIGATION. |
| | |
| | 7. WAIVER REQUEST #7 CREATES A NARROW BUFFER AREA AT |
| | THE SOUTHWEST CORNER OF THE PROPERTY, AND THE LIVE OAK |
| | PROPOSED DOES NOT FIT THE RESTRICTED SPACE BETWEEN THE |
| | SIDEWALK AND BUILDING. PLEASE CHANGE TO A MORE |
| | APPROPRIATE SPECIES. |
| | |
| | 8. THE GUMBO LIMBO TREES PROPOSED ALONG THE NORTH |
| | PROPERTY LINE WILL NOT PROVIDE BUFFERING FROM THE |
| | ADJACENT USE FOR A SUBSTANTIAL PART OF THE YEAR DUE TO |
| | LEAF DROP. PLEASE CONSIDER A MIX OF SPECIES TO PROVIDE |
| | MORE DIVERSITY AND YEAR ROUND BUFFERING. |
| | |
| | 9. PLEASE CORRECT THE TREE DISPOSITION PLAN FOR THE |
| | FOLLOWING: |
| | ? TREES TO BE RELOCATED NEED TO BE TAGGED WITH THEIR |
| | IDENTIFYING NUMBER, AND LOCATION SHOWN BY NUMBER ON THE |
| | PROPOSED LANDSCAPE PLAN |
| | ? PROVIDE THE CATEGORY AND QUANTITY FOR EACH TREE TO BE |
| | REPLACED 1:1 AND PROVIDE THE MITIGATION FOR THE TREE |
| | CANOPY REPLACEMENT AS A SEPARATE QUANTITY. |
| | ? PROVIDE AN ADDITIONAL COLUMN TO RECORD TREE CANOPY |
| | WIDTH 35 FEET OR MORE. |
| | |
| | 10. PLEASE PROVIDE A PLAN FOR THE RELOCATION SHOWING |
| | HOW TREES TO BE RELOCATED WILL BE STORED OR PLACED |
| | PERMANENTLY DURING DEMOLITION AND CONSTRUCTION. THIS |
| | NEEDS TO BE ADDRESSED AT A CONCEPTUAL LEVEL PRIOR TO |
| | APPROVAL TO ASSURE THAT IT IS POSSIBLE. |
| | |
| | 11. STREET TREES LOCATED IN A SIDEWALK SHALL HAVE |
| | STRUCTURAL SOIL EXTENDING 5 FEET IN ALL DIRECTIONS FROM |
| | THE TREE GRATE AND PLANTING PIT UP TO THE CURB. |
| | INDICATE STRUCTURAL SOIL LOCATIONS ON THE LANDSCAPE |
| | PLAN AND CORRECT THE TYPICAL STRUCTURAL SOIL DETAIL ON |
| | THE LANDSCAPE DETAIL PAGE. |
| | |
| | 12. THE TREE GRATES WILL BE U S FOUNDRY 9531 IF NO |
| | LIGHTING IS GOING TO BE INSTALLED. PLEASE VERIFY IF |
| | 9530 IS TO BE USED THAT LIGHTING WILL BE INSTALLED. |
| | |
| | 13. THERE ARE LOCATIONS OF LIGHTING ON THE LANDSCAPE |
| | PLAN THAT APPEAR TO CONFLICT WITH LANDSCAPING. PLEASE |
| | PROVIDE THE HEIGHT OF THE FIXTURES IN THESE AREAS. |
| | |
| | 14. PLEASE SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT |
| | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES |
| | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY |
| | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. |
| | |
| | 15. PLEASE SHOW LOCATIONS OF ALL GROUND MOUNTED |
| | EQUIPMENT INCLUDING FPL TRANSFORMERS, A/C UNITS, ETC., |
| | AND PROVIDE SCREENING FOR ALL GROUND MOUNTED EQUIPMENT |
| | AND UTILITIES. THERE ARE STILL SOME AREAS THAT NEED |
| | SCREENING. |
| | |
| | PLEASE UNDERSTAND THAT ADDITIONAL INFORMATION MAY BE |
| | REQUESTED, AND STAFF MAY HAVE ADDITIONAL COMMENTS AS |
| | THE REVIEW PROCESS CONTINUES. |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | 2. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE |
| | RESPONSIBLE FOR THE PERMITTING AND INSTALLATION OF THE |
| | STREET TREES, TREE GRATES, RIGHT OF WAY LANDSCAPING AND |
| | IRRIGATION APPROVED WITH THIS PETITION. |
| | 3. THE APPLICANT, SUCCESSORS AND ASSIGNS SHALL BE |
| | RESPONSIBLE FOR THE MAINTENANCE OF THE ROAD RIGHT OF |
| | WAY LANDSCAPING, TREE GRATES AND IRRIGATION ADJACENT TO |
| | THE PROPERTY. THIS WILL BE THROUGH A SEPARATE |
| | MAINTENANCE AGREEMENT WITH THE CITY. |
| | |
| |
Print |