2016-04-04 15:21:58GENERAL COMMENTS:
  
 1.) THE NAME OF THE BUSINESS IS "KWIK STOP #555" (NOT
 "QUICK STOP #555"). PLEASE CORRECT ON ALL SHEETS.
  
 2.) REFERENCE: "KWIK STOP #555" IN THE TITLE BAR ON
 SHEETS G-1.0 AND CE 1.0.
  
 3.) PLEASE ENSURE ALL CORRECTIONS MADE ARE CONSISTENT
 IN THE PLAN SET.
  
 4.) FDOT PRELIMINARY APPROVAL FOR THE ACCESS POINT ON
 MILITARY TRAIL HAD EXPIRED ON 4/2/16. PLEASE ADDRESS.
  
 SITE PLAN:
  
 1.) INCLUDE INFORMATION ON THE FLOOR AREA RATIO (FAR)
 AND LOADING AREA CALCULATIONS (REQUIRED: ONE (1) 10 FT.
 BY 25 FT. LOADING ZONE). [REPEAT COMMENT FROM 12/4/15]
  
 2.) ALL DIMENSIONS, INCLUDING BUT NOT LIMITED TO:
 SETBACKS, DRIVE AISLE WIDTHS, CURB CUTS, LOADING ZONE,
 DISTANCE BETWEEN PUMP ISLANDS, LANDSCAPE BUFFERS, ETC.
 SHALL BE PROVIDED IN THE SITE PLAN. [REPEAT COMMENT
 FROM 12/4/15]
  
 3.) PROVIDE SETBACK DIMENSIONS OF UNDERGROUND TANKS
 FROM THE PROPERTY LINE IN SHEET G-1.0. [REPEAT COMMENT
 FROM 12/4/15]
  
 4.) NEW LOCATION OF THE VACUUM PUMP SHALL BE LOCATED AT
 LEAST 5 FT. FROM THE FRONT PROPERTY LINE. [ZLDR
 S.94-145(2)]
  
 5.) THE REVISED SITE PLAN INDICATES THERE WILL BE A
 BICYCLE RACK LOCATED AT THE SOUTHEAST CORNER OF THE
 EXISTING CONVENIENCE STORE BUILDING. THE RACK SHOULD BE
 INSTALLED IN A HIGHLY VISIBLE LOCATION (I.E. BUILDING
 FRONTAGE) TO DETER THEFT.
  
 6.) THE PROPOSED BICYCLE RACK DOES NOT MEET THE MINIMUM
 DIMENSIONS FOR A RACK PURSUANT TO THE CITY?S BICYCLE
 PARKING STANDARDS. INCLUDE A RACK DETAIL; THE DETAIL
 SHALL BE CONSISTENT WITH THE REQUIREMENTS OF THE CITY?S
 BICYCLE PARKING STANDARDS.
  
 LANDSCAPE PLAN:
  
 1.) SHOW PROPOSED LIGHT POLES AND EXISTING UTILITY
 LINES IN THE LANDSCAPE PLAN TO ENSURE THERE IS NO
 CONFLICT WITH THE LANDSCAPING.
  
 2.) BICYCLE RACK MISSING IN THE LANDSCAPE PLAN.
  
 LIGHTING PLAN:
 1.) ALL PROPOSED LIGHT POLES MUST BE PLACED AT LEAST 5
 FT. FROM THE PROPERTY LINE. THE PROPOSED LIGHT POLES
 LOCATED ALONG THE NORTH PROPERTY LINE AND SOUTHEAST
 CORNER OF THE PROPERTY DOES NOT SEEM TO MEET THE
 MINIMUM SETBACK REQUIREMENT. [ZLDR S.94-145(2)]
  
 NOTES:
 1.) A UNITY OF TITLE JOINING 5653 NORTH MILITARY TRAIL
 AND 5665 NORTH MILITARY TRAIL WILL BE REQUIRED FOR THE
 PROPERTY WHEN APPROVED. PLEASE CONTACT THE ENGINEERING
 SERVICES DEPARTMENT FOR INFORMATION (516-494-1040)
  
 INSTRUCTIONS FOR RESUBMITTAL:
  
 * PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN
 WRITTEN FORMAT.
  
 * WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF SIX
 (6) PAPER COPIES, ONE (1) REDUCED COPY IN 8.5 INCHES X
 11 INCHES AND ONE (1) SET IN 11 INCHES X 17 INCHES, AND
 AN ELECTRONIC COPY OF ALL PLANS.
  
 * PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ASSESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20 PERCENT OF THE ORIGINAL APPLICATION FEE
 ($270).
  
 * ANY REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL
 COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.