| 2015-12-08 08:24:41 | CITY OF WEST PALM BEACH |
| | PUBLIC WORKS DEPARTMENT |
| | |
| | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL |
| | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION |
| | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE |
| | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT |
| | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT |
| | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT |
| | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO SITE |
| | PLAN APPROVAL. |
| | |
| | 1. REGARDING THE SUBMITTED BOUNDARY AND TOPOGRAPHIC |
| | SURVEY: |
| | A. PLEASE SUBMIT A SURVEY WHICH HAS BEEN SIGNED/SEALED |
| | BY PROFESSIONAL SURVEYOR AND MAPPER. |
| | B. LEGAL DESCRIPTION IS NOT LEGIBLE. PLEASE RESUBMIT |
| | WITH A LEGIBLE LEGAL DESCRIPTION. |
| | C. PLEASE LIST THE OVERALL PARCEL ACREAGE. |
| | D. PLEASE CHECK THE SCALE OF THE SURVEY. SCALE BAR AND |
| | NOTE INDICATE 1?:40?. SHOWN DIMENSIONS ARE CLOSE TO |
| | 1?=20?, BUT DO NOT SCALE TO THE EXACT DIMENSIONS. |
| | E. LOCATION MAP IS NOT LEGIBLE. |
| | F. LABEL PROPERTY CORNERS ON SURVEY. |
| | G. SHOW POC/POB ON SURVEY. |
| | H. PROVIDE PARENT BENCH MARK INFORMATION. |
| | I. NOTE 9 ON THE SURVEY REFERENCES THE CENTERLINE OF |
| | 55TH STREET. 55TH STREET IS NOT SHOWN ON THE SURVEY. |
| | J. IT APPEARS THAT AN INCORRECT BEARING BASE IS LISTED |
| | IN NOTE 9. |
| | K. LABEL THE WALL AND FENCE ALONG THE WESTERN PROPERTY |
| | LINE. |
| | L. REMOVE MIAMI-DADE REFERENCE IN THE LEGEND. |
| | M. PROVIDE TWO ON-SITE BENCH MARKS. |
| | |
| | 2. PLEASE REVISE THE DRIVEWAY APRONS TO MEET THE CITY?S |
| | ENGINEERING DESIGN STANDARDS. HTTP://WPB.ORG/ENGINEERIN |
| | G/ENGINEERING-SERVICES/ENGINEERING-STANDARDS/ |
| | |
| | 3. PLEASE PROVIDE AN AUTOTURN ANALYSIS DEMONSTRATING |
| | THE SOLID WASTE COLLECTION VEHICLE CAN ACCESS THE |
| | PROPOSED DUMPSTER AND COMPACTOR LOCATIONS. THE TRASH |
| | DUMPSTER/COMPACTORS MUST LOCATED IN AREAS EASILY |
| | SERVICED BY THE CITY SANITATION EQUIPMENT AND MANPOWER |
| | PER SECTION 74-35(A)(5) OF THE CODE OF ORDINANCES. |
| | PLEASE ALSO SHOW HOW THE FUEL TRUCKS WILL ACCESS AND |
| | LEAVE THE SITE. |
| | |
| | 4. PLEASE REVISE THE PLANS TO INCLUDE THE CITY OF WEST |
| | PALM BEACH GARBAGE RECEPTACLE DETAIL. MINIMUM |
| | DIMENSIONAL REQUIREMENTS ARE LISTED IN SECTION |
| | 94-444(B) OF THE CODE OF ORDINANCES. CITY STANDARD |
| | DETAIL GC-8 MAY BE DOWNLOADED AT HTTP://WPB.ORG/ENGINEE |
| | RING/ENGINEERING-SERVICES/ENGINEERING-STANDARDS/ |
| | |
| | 5. PRELIMINARY, UPDATED FEMA FLOOD INSURANCE MAPS ARE |
| | AVAILABLE AT HTTP://WWW.CO.PALM-BEACH.FL.US/NEWSROOM/08 |
| | 14/08-26-14-FLOOD_MAPS.HTM. PLEASE REVIEW THE MAPS AND |
| | VERIFY THAT THE NEW MAPS WILL NOT IMPACT THE PROPOSED |
| | PROJECT. |
| | |
| | 6. THE EXISTING SITE HAS EXISTING DIMENSIONAL |
| | NON-CONFORMANCES (SECTION 94-513 OF THE CODE OF |
| | ORDINANCES), SOME OF WHICH WERE AUTHORIZED BY SPECIAL |
| | EXCEPTION #1350 ISSUED IN 1967. |
| | A. EXISTING DRIVEWAYS OFF OF WINDSOR ARE SEPARATED BY |
| | 55 FEET, WHICH IS LESS THAN THE MINIMUM SEPARATION (125 |
| | FT) REQUIRED BY CODE SECTION 94-313. |
| | B. TURN AROUND SPACES ARE NOT PROVIDED AT EITHER OF THE |
| | EXISTING DEAD-END DRIVE AISLES (CODE SECTION 94-485). |
| | C. EXISTING SOUTHERN ENTRANCE IS 35 FEET FROM THE |
| | INTERSECTION, RATHER THAN THE REQUIRED 50 FEET. (CODE |
| | SECTION 94-313) |
| | D. NONRESIDENTIAL USES WITH LESS THAN 300 REQUIRED |
| | PARKING SPACES ARE PERMITTED ONE ACCESS POINT ONTO EACH |
| | RIGHT-OF-WAY. THIS SITE CURRENTLY HAS TWO ACCESS POINTS |
| | OFF OF WINDSOR. (CODE SECTION 94-313) |
| | E. SIDEWALK WIDTH ALONG WINDSOR IS FOUR FEET INSTEAD OF |
| | THE CITY STANDARD WIDTH OF FIVE FEET. |
| | |
| | 7. THE EXISTING CURB CUT ON WINDSOR AT THE ALLEY |
| | ENTRANCE MUST BE REMOVED AND THE SIDEWALK AND |
| | CURB/GUTTER CONSTRUCTED TO MATCH THE REMAINDER OF |
| | WINDSOR ROAD. |
| | |
| | 8. PLEASE EXPLAIN WHY THE SITE PLAN SHOWS A PORTION OF |
| | THE ALLEY OUTSIDE OF THIS PARCEL AS ?ABANDONED ALLEY?. |
| | |
| | 9. PLEASE DEMONSTRATE THAT THE PROJECT WILL PROVIDE |
| | ADEQUATE DRAINAGE AND STORMWATER MANAGEMENT. COMPLIANCE |
| | WITH CHAPTER 40E-4 WILL DEMONSTRATE COMPLIANCE WITH |
| | THIS PROVISION [SECTIONS 90-201, 94-35(C )(11), AND |
| | 94-307]. |
| | |
| | 10. PLEASE REVIEW THE MINIMUM PERIMETER BERM ELEVATION |
| | LISTED ON SHEET C-1.0. IT IS 10 FEET BELOW THE LOWEST |
| | EXISTING ELEVATION ON THE PROPERTY. |
| | |
| | 11. PLEASE PROVIDE POLLUTANT CONTROL BAFFLES IN |
| | STORMWATER INLETS NEAR THE PROPOSED GAS ISLANDS. |
| | |
| | 12. PLEASE SUBMIT COUNTY APPROVAL OF THE EXISTING |
| | DRIVEWAY ENTRANCE ON 45TH STREET. |
| | |
| | 13. PLEASE VERIFY COMPLIANCE WITH ADA ACCESSIBLE ROUTE |
| | WIDTH REQUIREMENTS IN AREAS OF SIDEWALK WHERE VENDOR |
| | MACHINES (I.E. REDBOX, ICE) ARE PROPOSED. |
| | |
| | 14. PLEASE REVISE THE LANDSCAPE PLAN TO SHOW LOCATIONS |
| | OF ALL WATER METERS, VALVES, CLEAN-OUTS, LIGHT POLES, |
| | ETC. ROOT BARRIERS MAY BE REQUIRED WHERE PLANTINGS ARE |
| | NEAR UNDERGROUND STORMWATER, SANITARY, OR POTABLE WATER |
| | LINES. |
| | |
| | 15. PLEASE SHOW THE SIGHT TRIANGLES ON THE GROUND FLOOR |
| | LANDSCAPING PLAN FOR THE INTERSECTIONS AND VEHICULAR |
| | EXITS. (SECTION 94-305E, CODE OF ORDINANCES) |
| | |
| | THE FOLLOWING COMMENTS MUST BE ADDRESSED PRIOR TO |
| | ISSUANCE OF CONSTRUCTION AUTHORIZATION INCLUDING |
| | BUILDING PERMITS AND ENGINEERING DEVELOPMENT APPROVAL. |
| | |
| | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL |
| | BE REQUIRED FROM THE ENGINEERING DIVISION OF THE PUBLIC |
| | WORKS DEPARTMENT. THE ENGINEERING DEVELOPMENT APPROVAL |
| | APPLICATION FORMS CAN BE DOWNLOADED AT |
| | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ |
| | |
| | 2. A UNITY OF TITLE APPLICATION WILL BE REQUIRED FROM |
| | THE ENGINEERING DIVISION OF THE PUBLIC WORKS |
| | DEPARTMENT. THE APPLICATION FOR UNITY OF TITLE CAN BE |
| | DOWNLOADED AT |
| | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ |
| | |
| | KELLY CRANFORD, P.E. |
| | CAPITAL IMPROVEMENT PLAN MANAGER |
| | [email protected] |
| | 561-494-1098 (OFFICE) |
| | |
| | VINCE NOEL, PSM |
| | CITY SURVEYOR / REAL ESTATE SUPERVISOR |
| | [email protected] |
| | 561-494-1096 |
| | |
| | BRIAN COLLINS, PE |
| | CITY TRAFFIC ENGINEER |
| | [email protected] |
| | 561-494-1040 |
| | |
| | FERDINAND RIVERA |
| | PUBLIC WORKS OPERATIONS MANAGER |
| | [email protected] |
| | 561-822-2076 |
| | |
| | TRACY WARD, PE |
| | SENIOR STORMWATER ENGINEER |
| | 561-494-1120 |
| | [email protected] |
| | |
| | |
| |