Notes
Date Text
2015-11-10 16:22:031. EXISTING BACK OF CURB ON TRINITY PLACE ALONG THE
 CITY PLAZA II BUILDING SHALL BE CONTINUED WEST AND
 ADJUSTED IN FRONT OF THE CANOPY HOTEL IF NECESSARY. NEW
 CURB CUT WILL BE THE NEW BACK OF CURB FOR THE PURPOSES
 OF MEASURING THE SETBACK REQUIREMENTS.
 2. TRAVEL LANE WIDTH SHALL BE MAINTAINED CONSISTENT
 FROM OLIVE AVE TO DIXIE HWAY AND CURB SHALL BE ADJUSTED
 IF NECESSARY.
 3. SETBACKS ARE MEASURED FROM BACK OF CURB (EXISTING
 CURB ON DIXIE HWAY, AND NEW CURB ON TRINITY PLACE).
 4. DOORS SHALL NOT SWING OVER THE MINIMUM REQUIRED
 SETBACK.
 5. PLEASE EXPLAIN HOW THE PARKING OPERATION IS GOING TO
 FUNCTION. SOME CONCERNS ARE:
 - CARS WAITING FOR THE ELEVATOR SHALL NOT BE STACKED
 IN THE PUBLIC ROW.
 - HOW LONG DOES IT TAKE FOR THE ELEVATOR TO GO UP AND
 DOWN?
 - WHAT HAPPENS IF THE ELEVATOR BREAKS DOWN?
 6. ACTIVE USES ARE REQUIRED ALONG 60% OF DIXIE HWAY ON
 ALL FLOORS UP TO 5TH STORY. PROJECT IS PROPOSEING
 PARKING USES ON FLOORS 3RD TO 5TH.
 7. PARKING IS ALLOWED ABOVE THE 5TH STORY WITHOUT
 ACTIVE USES, BUT A CONDITIONAL SETBACK OF 31? IS
 REQUIRED.
 8. PARKING IS ALLOWED ABOVE THE 5TH STORY WITHOUT
 ACTIVE USES, BUT A CONDITIONAL SETBACK OF 27? IS
 REQUIRED.
 9. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE
 WITH THE FA?ADE ARTICULATION REQUIREMENTS. PLEASE
 CONFIRM COMPLIANCE WITH FENESTRATION REQUIREMENTS AND
 COMPLIANCE WITH PROHIBITION FOR BLANK WALLS.
 10. PROPOSED HOTEL IS NOT PROVIDING ANY LOADING AREA.
 PLEASE EXPLAIN HOW THE HOTEL IS GOING TO BE SERVICED
 WITHOUT A DEDICATED LOADING AREA. TRINITY PLACE IS A
 SINGLE LANE ROAD AND IT CANNOT BE BLOCK AT ANY TIME.
 11. HOW IS THE PROJECT PROPOSING TO HANDLE GARBAGE
 COLLECTION?
 12. COMPATIBILITY WITH ADJACENT CITYPLAZA II BUILDING.
 FURTHER DISCUSSION NEEDED REGARDING THE PODIUM HEIGHT
 IN RELATION WITH THE CPII PODIUM HEIGHT, AND THE
 RELATIONSHIP OF SOME DESIGN ELEMENTS BETWEEN THE TWO
 BUILDINGS. THE GOAL IS TO MAKE THE ENTIRE BLOCK TO WORK
 AS A CONSISTENT URBAN BLOCK.
 13. PLEASE EXPLAIN ANY ACTIONS TAKEN TO MINIMIZE THE
 NOISE AND LIGHT POLLUTION FROM THE ROOFTOP TERRACES
 INTO THE ADJACENT RESIDENTIAL BUILDING.
 14. PLEASE PROVIDE ANY INFORMATION ON HOW THE REAR AND
 SIDE SETBACKS ARE GOING TO BE TREATED AT GROUND LEVEL.
 THERE SEEM TO BE SOME ODD LEFT OVER AREAS.
 15. SIDEWALK TREATMENT ON TRINITY PLACE SHALL CONTINUE
 THE EXISTING TREATMENT/PATTERN ON THE EAST SIDE.
 16. IS THE GROUND FLOOR RESTAURANT PROPOSED WITH ACCESS
 FROM DIXIE HWAY AND OUTDOOR SEATING?
 SUBMITTAL COMMENTS:
 1. PLEASE PROVIDE REDUCED DIAGRAMS OF EVERY FLOOR
 INDICATING THE AREAS THAT ARE COUNTED AS PART OF THE
 GROSS BUILDING AREA AND THE AREAS THAT ARE NOT. INCLUDE
 SQUARE FOOTAGE IN A SUMMARY TABLE.
 2. PLEASE PROVIDE COLORED ELEVATIONS WITH THE
 SURROUNDING CONTEXT. ELEVATIONS SHALL CONTAIN
 INFORMATION TO INDICATE ANY PLANAR BREAKS AND ITS
 DEPTH.
 3. PLEASE PROVIDE PEDESTRIAN LEVEL RENDERINGS OF THE
 PROPOSED HOTEL.
 4. PLEASE PROVIDE IMAGES OF PROPOSED FA?ADE MATERIALS
 AND GARAGE ARCHITECTURAL TREATMENT WITH GENERAL
 INFORMATION ON PROPOSED MATERIAL.
  