| Date |
Text |
| 2015-11-10 16:22:03 | 1. EXISTING BACK OF CURB ON TRINITY PLACE ALONG THE |
| | CITY PLAZA II BUILDING SHALL BE CONTINUED WEST AND |
| | ADJUSTED IN FRONT OF THE CANOPY HOTEL IF NECESSARY. NEW |
| | CURB CUT WILL BE THE NEW BACK OF CURB FOR THE PURPOSES |
| | OF MEASURING THE SETBACK REQUIREMENTS. |
| | 2. TRAVEL LANE WIDTH SHALL BE MAINTAINED CONSISTENT |
| | FROM OLIVE AVE TO DIXIE HWAY AND CURB SHALL BE ADJUSTED |
| | IF NECESSARY. |
| | 3. SETBACKS ARE MEASURED FROM BACK OF CURB (EXISTING |
| | CURB ON DIXIE HWAY, AND NEW CURB ON TRINITY PLACE). |
| | 4. DOORS SHALL NOT SWING OVER THE MINIMUM REQUIRED |
| | SETBACK. |
| | 5. PLEASE EXPLAIN HOW THE PARKING OPERATION IS GOING TO |
| | FUNCTION. SOME CONCERNS ARE: |
| | - CARS WAITING FOR THE ELEVATOR SHALL NOT BE STACKED |
| | IN THE PUBLIC ROW. |
| | - HOW LONG DOES IT TAKE FOR THE ELEVATOR TO GO UP AND |
| | DOWN? |
| | - WHAT HAPPENS IF THE ELEVATOR BREAKS DOWN? |
| | 6. ACTIVE USES ARE REQUIRED ALONG 60% OF DIXIE HWAY ON |
| | ALL FLOORS UP TO 5TH STORY. PROJECT IS PROPOSEING |
| | PARKING USES ON FLOORS 3RD TO 5TH. |
| | 7. PARKING IS ALLOWED ABOVE THE 5TH STORY WITHOUT |
| | ACTIVE USES, BUT A CONDITIONAL SETBACK OF 31? IS |
| | REQUIRED. |
| | 8. PARKING IS ALLOWED ABOVE THE 5TH STORY WITHOUT |
| | ACTIVE USES, BUT A CONDITIONAL SETBACK OF 27? IS |
| | REQUIRED. |
| | 9. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE |
| | WITH THE FA?ADE ARTICULATION REQUIREMENTS. PLEASE |
| | CONFIRM COMPLIANCE WITH FENESTRATION REQUIREMENTS AND |
| | COMPLIANCE WITH PROHIBITION FOR BLANK WALLS. |
| | 10. PROPOSED HOTEL IS NOT PROVIDING ANY LOADING AREA. |
| | PLEASE EXPLAIN HOW THE HOTEL IS GOING TO BE SERVICED |
| | WITHOUT A DEDICATED LOADING AREA. TRINITY PLACE IS A |
| | SINGLE LANE ROAD AND IT CANNOT BE BLOCK AT ANY TIME. |
| | 11. HOW IS THE PROJECT PROPOSING TO HANDLE GARBAGE |
| | COLLECTION? |
| | 12. COMPATIBILITY WITH ADJACENT CITYPLAZA II BUILDING. |
| | FURTHER DISCUSSION NEEDED REGARDING THE PODIUM HEIGHT |
| | IN RELATION WITH THE CPII PODIUM HEIGHT, AND THE |
| | RELATIONSHIP OF SOME DESIGN ELEMENTS BETWEEN THE TWO |
| | BUILDINGS. THE GOAL IS TO MAKE THE ENTIRE BLOCK TO WORK |
| | AS A CONSISTENT URBAN BLOCK. |
| | 13. PLEASE EXPLAIN ANY ACTIONS TAKEN TO MINIMIZE THE |
| | NOISE AND LIGHT POLLUTION FROM THE ROOFTOP TERRACES |
| | INTO THE ADJACENT RESIDENTIAL BUILDING. |
| | 14. PLEASE PROVIDE ANY INFORMATION ON HOW THE REAR AND |
| | SIDE SETBACKS ARE GOING TO BE TREATED AT GROUND LEVEL. |
| | THERE SEEM TO BE SOME ODD LEFT OVER AREAS. |
| | 15. SIDEWALK TREATMENT ON TRINITY PLACE SHALL CONTINUE |
| | THE EXISTING TREATMENT/PATTERN ON THE EAST SIDE. |
| | 16. IS THE GROUND FLOOR RESTAURANT PROPOSED WITH ACCESS |
| | FROM DIXIE HWAY AND OUTDOOR SEATING? |
| | SUBMITTAL COMMENTS: |
| | 1. PLEASE PROVIDE REDUCED DIAGRAMS OF EVERY FLOOR |
| | INDICATING THE AREAS THAT ARE COUNTED AS PART OF THE |
| | GROSS BUILDING AREA AND THE AREAS THAT ARE NOT. INCLUDE |
| | SQUARE FOOTAGE IN A SUMMARY TABLE. |
| | 2. PLEASE PROVIDE COLORED ELEVATIONS WITH THE |
| | SURROUNDING CONTEXT. ELEVATIONS SHALL CONTAIN |
| | INFORMATION TO INDICATE ANY PLANAR BREAKS AND ITS |
| | DEPTH. |
| | 3. PLEASE PROVIDE PEDESTRIAN LEVEL RENDERINGS OF THE |
| | PROPOSED HOTEL. |
| | 4. PLEASE PROVIDE IMAGES OF PROPOSED FA?ADE MATERIALS |
| | AND GARAGE ARCHITECTURAL TREATMENT WITH GENERAL |
| | INFORMATION ON PROPOSED MATERIAL. |
| | |
| |