| Date |
Text |
| 2016-01-05 10:28:42 | FROM: RAY CARANCI, LANDSCAPE PLANNER 561-822-1462 |
| | PROJECT: 1255 PALM BEACH LAKES RESUBMITTAL 1/4 |
| | Z15090030 |
| | JANUARY 4, 2015 |
| | I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND |
| | PROVIDE THE FOLLOWING COMMENTS: |
| | |
| | 1. PARTIALLY SATISFIED. PLEASE PROVIDE A TREE SURVEY |
| | IDENTIFYING EXISTING TREES ON THE PROPERTY AND INDICATE |
| | THE SPECIES, SIZE, AND IF THEY WILL BE REMOVED, |
| | RELOCATED, OR REMAIN. PLEASE PROVIDE A MITIGATION CHART |
| | TO REFLECT THE TREE INVENTORY, AND PROVIDE PERTINENT |
| | INFORMATION FOR EACH TREE PER SECTION 94-448 (E) |
| | INCLUDING SPECIES, CANOPY SIZE AND REPLACEMENT |
| | REQUIREMENT FOR ANY TREES PROPOSED TO BE REMOVED. |
| | PLEASE CORRECT THE FOLLOWING ON THE TREE DISPOSITION |
| | PLAN: |
| | ? ALL TREES WITH A CANOPY OF LESS THAN 35 FEET MUST BE |
| | MITIGATED 1:1 WITH A TREE IN THE SAME CATEGORY. |
| | INDICATE THIS ON THE CHART. |
| | ? ALL TREES WITH A CANOPY 35 FEET OR OVER MUST BE |
| | MITIGATED WITH A CORRESPONDING SQUARE FOOTAGE OF |
| | CANOPY. INDICATE THIS ON THE CHART. |
| | ? THERE ARE SEVERAL EXISTING TREES ON SITE THAT THE |
| | LISTED CONDITION NEEDS TO BE VERIFIED IN ORDER TO |
| | PRESERVE ALL HEALTHY TREES ON SITE. STAFF DOES NOT |
| | SUPPORT REMOVAL OF HEALTHY TREES FROM THE EXISTING |
| | BUFFERS. |
| | ? THE MITIGATION SHOWING PROPOSED TREES NEEDS TO BE |
| | INCLUDED IN THE TREE DISPOSITION CHART. |
| | |
| | 2. NOT SATISFIED. PLEASE PROVIDE THE REQUIRED OPEN |
| | SPACE CALCULATION TO REFLECT THE REQUIRED 40 PERCENT OF |
| | THE TOTAL SITE AREA AND PROVIDE ALL REQUIRED SHADE AND |
| | FLOWERING TREE AND SHRUB CALCULATIONS PER SECTION |
| | 94-442. |
| | THE SQUARE FOOTAGE PROVIDED FOR THE GROSS LOT AREA IS |
| | INCORRECT AND DOES NOT MATCH THE SURVEY DATA. BASED ON |
| | 74067.84 SQ FT GROSS LOT AREA, THE 40% TO BE USED FOR |
| | TREE, FLOWERING TREE AND SHRUB MINIMUM REQUIREMENTS IS |
| | 29627.36 SQ FT. PLEASE REVISE ALL CALCULATIONS. |
| | |
| | 3. SATISFIED. PLEASE REMOVE REFERENCES TO SECTION |
| | 94-113, AS THIS IS NOT APPLICABLE. |
| | 94-113 IS STILL REFERENCED ON SHEET CFG8.2. |
| | |
| | 4. SATISFIED. TREES, PALMS AND SHRUBS PROPOSED TO BE |
| | PLANTED IN THE RIGHT OF WAY CANNOT BE COUNTED TOWARD |
| | ONSITE REQUIREMENTS. PLEASE PROVIDE A SEPARATE PLANT |
| | LIST FOR ANY OFF SITE LANDSCAPING. |
| | |
| | 5. NOT SATISFIED. PLEASE PROVIDE THE REQUIRED TREES FOR |
| | ALL LANDSCAPE BUFFERS ON SITE PER SECTION 94-443. |
| | |
| | CALCULATIONS ARE TO BE BASED ON THE ENTIRE LENGTH OF |
| | THE BUFFER ON EACH SIDE OF THE LOT, AND A TREE PROVIDED |
| | FOR EACH 30 FEET OR PORTION THEREOF. |
| | SEE SECTION 94-443(B)(4) ..PAVED AREAS USE FOR |
| | PEDESTRIAN CIRCULATION AND VEHICULAR ACCESS SHALL BE |
| | INCLUDED WHEN CALCULATING THE LENGTH OF THE BUFFER |
| | STRIP. |
| | |
| | 6. NOT SATISFIED. A LANDSCAPE ISLAND MUST BE PROVIDED |
| | ON THE NORTH END OF THE ROW OF PARKING ALONG THE WEST |
| | SIDE OF THE BUILDING PER SECTION 94-443(C)(3). |
| | THE ISLAND MUST BE AT LEAST 5 FEET IN WIDTH NOT |
| | INCLUDING THE CURB. |
| | |
| | 7. SATISFIED. PLEASE PROVIDE A SCREENING HEDGE ON THE |
| | WEST SIDE OF THE DUMPSTER ENCLOSURE. |
| | |
| | 8. SATISFIED. PLEASE SHOW COMPLIANCE WITH SECTION |
| | 94-443(C)(3) AND (4) TO PROVIDE THE REQUIRED LANDSCAPE |
| | AREAS WITHIN THE PARKING AREAS BASED ON PARKING SPACES |
| | AND OTHER PAVED AREAS. |
| | CALCULATIONS COULD NOT BE LOCATED. |
| | |
| | 9. SATISFIED. PLEASE SHOW COMPLIANCE WITH SECTION |
| | 94-443(E) AND PROVIDE LANDSCAPING FOR AT LEAST 30 |
| | PERCENT OF THE LINEAR FEET AROUND THE EXTERIOR OF THE |
| | BUILDING. |
| | THE REAR OF THE BUILDING DOES NOT QUALIFY, AS IT IS THE |
| | HEDGE FOR THE BUFFER, AND SIDEWALKS SEPARATE IT FROM |
| | THE BUILDING. |
| | |
| | 10. NOT SATISFIED. PLEASE PROVIDE A ROOT BARRIER DETAIL |
| | AND SHOW LOCATIONS OF ROOT BARRIERS TO PROTECT |
| | INFRASTRUCTURE AND TREES FROM CONFLICTS. THIS INCLUDES |
| | WATER, SEWER, DRAINAGE, SIDEWALKS AND CURBS, AND ANY |
| | FIELD STRUCTURES THAT COULD BE IMPACTED BY TREE ROOTS. |
| | |
| | 11. NOT SATISFIED. PLEASE SHOW ALL UTILITIES INCLUDING |
| | FPL, WATER, SEWER, AND DRAINAGE ON THE LANDSCAPE PLAN. |
| | PLEASE PROVIDE SCREENING FOR ALL GROUND MOUNTED |
| | EQUIPMENT AND UTILITIES. |
| | LOCATIONS OF ABOVE GROUND VALVES, FPL, ETC. MUST BE |
| | SHOWN AND SCREENING SHOWN ON LANDSCAPE PLAN. UTILITIES |
| | HAVE BEEN REMOVED FROM RESUBMITTED LANDSCAPE PLAN. |
| | |
| | |
| | ADDITIONAL COMMENTS 11/20/15: |
| | |
| | 12. NOT SATISFIED. PLEASE PROVIDE A TREE PROTECTION |
| | PLAN SHOWING LOCATIONS OF TREE PROTECTION BARRIERS ON |
| | THE SAME SHEET WITH THE TREE PROTECTION DETAIL. |
| | |
| | PLEASE UNDERSTAND THAT ADDITIONAL INFORMATION MAY BE |
| | REQUESTED, AND STAFF MAY HAVE ADDITIONAL COMMENTS AS |
| | THE REVIEW PROCESS CONTINUES. |
| | |
| | CONDITIONS OF APPROVAL |
| | 1. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON |
| | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE |
| | SUBMITTED, REVIEWED AND APPROVED BY THE DEVELOPMENT |
| | SERVICES DEPARTMENT, PLANNING DIVISION. |
| | |
| |
Print |