Text |
| 2015-12-15 11:42:32 | 2ND REVIEW. |
| | 1. PASSENGER DROP-OFF AREA IS NOT ALLOWED ALONG |
| | QUADRILLE BOULEVARD.- COMPLIED |
| | 2. CURB CUTS ARE NOT PERMITTED ALONG QUADRILLE BLVD. |
| | BANK DRIVE THRU EXIT CAN UTILIZE THE EXISTING ALLEY.- |
| | COMPLIED |
| | 3. STREET TREES SHALL BE PLANTED ALONG THE STREET |
| | FRONTAGE, ADJACENT TO THE CURB. TREE GRATES SHALL BE |
| | INSTALLED ON THOSE TREES ALONG GARDENIA STREET AND |
| | DIXIE HWAY. TREES SHALL BE INSTALLED ON GRASS STRIP |
| | ALONG QUADRILLE BLVD TO MAINTAIN CONSISTENCY ON THE |
| | STREETSCAPE. COMPLIED. PLEASE ADD ONE ADDITIONAL TREE |
| | ALONG GARDENIA BETWEEN THE FIRST AND THE THIRD TREE |
| | COUNTING FROM QUADRILLE. A ROOT BARRIER WILL SUFFICE TO |
| | AVOID ANY CONFLRICT WITH THE UTILITY LINE. |
| | 4. PLEASE CLARIFY THE GARAGE ENTRANCE, IT SHOWS ONLY |
| | ONE ENTRANCE ARROW BUT IT SEEMS IT SHALL BE TWO-WAY |
| | DRIVEWAY.- COMPLIED |
| | 5. PLEASE EXPLORE THE POSSIBILITY TO REDUCE THE NUMBER |
| | OF CURB CUTS ALONG GARDENIA STREET.- COMPLIED. |
| | 6. PLEASE EXPLORE THE POSSIBILITY TO MOVE THE GROUND |
| | FLOOR PARKING SPACE BEHIND, AND THE OFFICE LOBBY ALONG |
| | THE STREET FRONTAGE.- COMPLIED |
| | 7. IS THERE ANY ACCESS AGREEMENT BETWEEN VITAL PRINTING |
| | AND THE RUSSOS SUB PROPERTY?- ACKNOWLEDGED |
| | 8. THE NON-ACTIVE USES SHALL BE ARCHITECTURALLY TREATED |
| | ACCORDING TO SEC 94-109. SEE ALSO TABLE IV-4. COMPLIED. |
| | PLEASE PROVIDE MORE PICTURES OF THE SPECIFIC PRODUCT |
| | SPECIFIED FOR THE SCREENING. |
| | 9. PLEASE CONFIRM COMPLIANCE WITH BLANK WALL |
| | REGULATIONS FOR NORTH AND EAST ELEVATIONS. NOT |
| | COMPLIED. PLEASE CALCULATE THE EXACT SQUARE FOOTAGE OF |
| | THE WALL NOW PROPOSED AS A GREEN WALL. THE MAXIMUM AREA |
| | OF SUCH WALL ALLOWED WITH NO OPENINGS IS 10,556SF BASED |
| | ON THE TOTAL AREA OF THE FACADE OF 52,781 SF. |
| | 10. CURB CUT ON DIXIE HWAY IS NOT DESIRABLE, PLEASE |
| | CONSIDER UTILIZING THE ALLEY OR AT A MINIMUM REDUCING |
| | THE CURB CUT TO ONLY ONE TRAVEL LANE. COMPLIED. STAFF |
| | STILL SUGGEST TO LOOK FOR ALTERNATIVES TO REMOVE THE |
| | CURB CUT ON DIXIE. |
| | 11. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE |
| | WITH PLANAR BREAK REGULATIONS (TABLE IV-4). COMPLIED. |
| | 12. THE PROJECT REQUIRES THE ACQUISITION OF TDRS. |
| | PLEASE INDICATE THE SOURCE OF THE TDRS. ACKNOWLEDGED |
| | |
| | DOCUMENT SET |
| | 13. PLEASE INDICATE THE REQUIRED SETBACK AND PROPERTY |
| | LINE IN ALL FLOOR PLANS AND ELEVATIONS. NOT COMPLIED. |
| | PLEASE PROVIDE THE REQUIRED SETBACK AS MEASURED FROM |
| | THE BACK OF THE CURB ON SITE PLAN AND FLOOR PLANS AND |
| | ELEVATIONS. |
| | 14. THE GROSS BUILDING AREA CALCULATION TABLE SHALL |
| | INDICATE THE BASE DEVELOPMENT CAPACITY (2.75 FAR) AND |
| | IN A SEPARATE LINE THE INCENTIVE CAPACITY (ADDITIONAL |
| | 2.75 FAR). PROJECT SITE 49,081SF. 2.75 FAR= 134,973 SF. |
| | ADDITIONAL FAR ALLOWED BY THE QUADRILLE GARDEN DISTRICT |
| | HOTEL AND OFFICE INCENTIVE = 134,973 SF. COMPLIED. |
| | SURVEY NEEDS TO BE REVISED AND CALCULATIONS ADJUSTED. |
| | 15. PARKING REQUIREMENT NUMBERS SHALL REFLECT THE DMP |
| | REQUIREMENTS (TABLE IV-9). COMPLIED. PLEASE ADJUST |
| | PARKING CALCULATION TO REFLECT HOTEL REQUIREMENT. |
| | 16. PLEASE INSERT THE 1ST FLOOR PLAN IN THE CONTEXT |
| | INDICATING THE ADJACENT BUILDINGS, ROADS, SIDEWALKS AND |
| | STREET ELEMENTS. INCLUDE THE FOUR CORNERS OF GARDENIA |
| | AND DIXIE, AND THE NORTH SIDE OF THE ALLEY. COMPLIED. |
| | 17. PLEASE PROVIDE COLORED ELEVATIONS WITH CALL OUT |
| | MATERIALS AND PICTURES REFERENCING THE PROPOSED |
| | FINISHES. COMPLIED. |
| | 18. ELEVATIONS FOR SMALL BUILDING SEEM TO BE |
| | MISLABELED. COMPLIED |
| | 19. PLEASE PROVIDE A SMALL DIAGRAM OF EACH FLOOR |
| | INDICATING THE AREAS COUNTED AS PART OF THE FAR. |
| | COMPLIED |
| | |
| | ADDITIONAL COMMENTS |
| | 20. REPEART COMMENT. THE SUBMITTED SURVEY DOES NOT |
| | APPEAR COMPLETE AND ACCURATE. PLEASE VERIFY FDOT |
| | MAINTENANCE MAPS FOR DIXIE HWAY, THE SITE IS SMALLER |
| | THAN REFLECTED ON SURVEY. FOR PURPOSES OF CALCULATING |
| | THE FAR, THE SURVEY NEEDS TO INCLUDE THE TOTAL SQUARE |
| | FOOTAGE OF THE PARCEL. |
| | 21. ENGINEERING COMMENTS REGARDING GARBAGE COLLECTION |
| | WILL AFFECT THE SITE PLAN. PLEASE ADJUST ENSURING |
| | COMPLIANCE. |
| | 22. PROJECT DOES NOT COMPLY WITH THE MINIMUM SETBACK |
| | REQUIRED WHEN PARKING USES ARE PROPOSED ABOVE THE 3RD |
| | FLOOR ALONG A SECONDARY STREET. MINIMUM SETBACK |
| | REQUIRED IS 27' MEASURED FROM THE BACK OF THE CURB. |
| | CURRENT PROJECT IS PROPOSING ONLY 17'. |
| | 23. MAXIMUM BUILDING SETBACK ALONG AN AVENUE IS 30' . |
| | PROPOSED PROJECT IS SET BACK 37' FROM THE BACK OF |
| | CURB.PLEASE ADJUST. |
| | 24. PLEASE VERIFY THE FACADE AND THE FLOOR PLANS MATCH |
| | IN RELATION TO THE LOCATION OF THE WINDOW, DOORS, |
| | OPENINGS ETC. (OFFICE LOBBY DOOR AND STAIR DOOR ON |
| | GARDENIA ARE NOT REFLECTED ON ELEVATION. |
| | 25. PLEASE INCLUDE DETAILS OF THE NEW GREEN WALLS |
| | PROPOSED ON THE NORTH FACADE. |
| | |
| |