| 2016-09-07 14:12:02 | CASE NO. PB 950SSSS |
| | HILTON CONVENTION CENTER HOTEL LOADING AREA - |
| | RESUBMITTAL |
| | 600 OKEECHOBEE BOULEVARD |
| | |
| | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | |
| | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR |
| | (4) FULL SIZED PAPER COPIES AND AN ELECTRONIC COPY IN |
| | .PDF FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON |
| | THE RESUBMITTED PLANS OR THE SUBMITTAL OF |
| | INFORMATION/PLANS TO ADDRESS THE COMMENTS MAY RESULT IN |
| | ADDITIONAL COMMENTS. |
| | |
| | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | ADDITIONAL RESUBMITTAL AT NO ADDITIONAL COST. IF |
| | PREVIOUSLY-ISSUED COMMENTS CONTINUE TO NOT BE |
| | SUFFICIENTLY ADDRESSED, THE APPLICANT WILL BE ACCESSED |
| | A RESUBMITTAL FEE. SUCH FEE WILL BE 20% OF THE ORIGINAL |
| | APPLICATION FEE ($60). |
| | |
| | 1) THANK YOU FOR PROVIDING THE TURNING RADIUS EXHIBIT |
| | FOR THE WB-50 TRUCK. THE EXHIBIT VERIFIES THAT THIS |
| | TRUCK IS UNABLE TO EXIT THE MIDDLE LOADING BAY ONTO |
| | FLORIDA AVENUE IF A SWING GATE IS USED. THE TRAILER |
| | WILL HIT THE OPEN GATE LEAVING THE SITE. PLEASE NOTE |
| | THAT SECTION 94-111(M) OF THE ZONING AND LAND |
| | DEVELOPMENT REGULATIONS PROHIBITS THE USE OF PUBLIC |
| | RIGHTS-OF-WAY FOR MANEUVERING ASSOCIATED WITH BUILDING |
| | LOADING AREAS, SO BACKING INTO THE STREET (REVERSING |
| | THE ENTRY MOVEMENT) IS NOT PERMITTED. THIS IS NOT AN |
| | ISSUE WITH THE CURRENTLY APPROVED GATE ARMS. ZONING |
| | STAFF WILL NOT APPROVE SWING GATES. |
| | |
| | 2) THE TURNING RADIUS EXHIBIT SHOWS THE GARBAGE TRUCK |
| | USING THE WESTERN LOADING SPACE AS MANEUVERING FOR TO |
| | TURN AROUND TO LEAVE THE SITE TO AVOID HITTING AN OPEN |
| | SWING GATE. HOW WILL THE TURNAROUND BE ACHIEVED IF |
| | THERE ARE TRUCKS PARKED IN THE LOADING ZONES? THIS IS |
| | NOT AN ISSUE WITH THE CURRENTLY APPROVED GATE ARMS. |
| | |
| | 3) REPEAT COMMENT: THE PLANS SHALL INCLUDE A SHEET TO |
| | REFLECT THE REVISED MEDIANS AND THE PEDESTRIAN CROSSING |
| | THAT ARE INCLUDED WITH THE APPROVED CONVENTION CENTER |
| | GARAGE PLAN. THIS INCLUDES FLORIDA AVENUE AND THE |
| | CONVENTION CENTER ENTRY DRIVE CROSSING FOR THE GARAGE |
| | DISCHARGE. PROVIDE THE TURNING RADIUS PLANS TO SHOW THE |
| | TRUCKS ENTERING AND LEAVING THE LOADING AREA WITH THE |
| | NEW CONFIGURATION. THE LATEST PLANS SUBMITTED TO THE |
| | CITY FAIL TO SHOW THE FINAL CONFIGURATION OF THE |
| | MEDIANS AS SHOWN ON THE PARKING GARAGE APPROVED PLANS, |
| | BUT RATHER SHOW ONLY THE GHOSTED ADDITION OF THE |
| | PEDESTRIAN CROSSING MEDIAN. THE TURNING MOVEMENTS SHOW |
| | TRUCKS HITTING THIS MEDIAN. |
| | |
| | 4) REPEAT COMMENT: THE SIDEWALK SOUTH OF THE WALL SHALL |
| | BE ILLUMINATED FOR SAFETY WITH LIGHT FIXTURES THAT |
| | MATCH THOSE USED FOR THE HOTEL. THIS MAY REQUIRE |
| | MOUNTING LIGHTING TO THE WALL. THE SHEET THAT WAS |
| | SUBMITTED TO SHOW THE LOCATIONS OF THE GARAGE LIGHTING |
| | FAILS TO SHOW THAT THE SIDEWALK WILL BE SAFELY |
| | ILLUMINATED. |
| | |
| | 5) REPEAT COMMENT: THE ENGINEER STAMPED DRAWING WITH |
| | THE BUILDING PERMIT SHOW THE WALL AT TEN FEET IN HEIGHT |
| | WHILE SHEET LS503 LD SHOWS THE WALL AT 11 FEET IN |
| | HEIGHT. ALL PLANS SHALL SHOW THE SAME WALL HEIGHT. |
| | |
| |