2016-06-02 12:59:30THE FOLLOWING COMMENTS WERE GENERATED AFTER THE REVIEW
 OF THE ARCHITECTURAL AND LANDSCAPE PLANS RECEIVED MAY
 3, 2016 BY THE CITY:
  
 1. NO ENGINEERING PLANS OTHER THAN A CONCEPTUAL
 DRAINAGE PLAN WERE SUBMITTED.
  
 2. PROVIDE A SCALE BAR ON THE SURVEY. BASED ON THE
 DIMENSIONS LISTED ON THE DRAWING, IT APPEARS THE
 GRAPHIC WAS REDUCED AND THE LISTED 1" = 20' SCALE IS
 NOT CORRECT.
  
 3. THE SITE IS BEING TOTALLY REDEVELOPED. STORMWATER
 TREATMENT WILL NEED TO BE PROVIDED IN ACCORDANCE WITH
 SFWMD CRITERIA.
  
 4. THE STORM PIPE CONNECTION TO THE EXISTING INLET ON
 DIXIE HIGHWAY WILL REQUIRE FDOT APPROVAL. DIXIE HIGHWAY
 IS A FDOT ROADWAY IN THIS AREA.
  
 5. PLEASE PROVIDE SEPARATE DRAWING SHOWING AUTOTURN
 ANALYSIS DEMONSTRATING THE SOLID WASTE COLLECTION
 VEHICLE CAN ACCESS THE PROPOSED DUMPSTER LOCATION.
  
 6. SHOW LIGHT POLES, PROPOSED UTILITIES AND EXISTING
 UTILITIES THAT WILL REMAIN ON THE LANDSCAPE PLAN. IT
 APPEARS SOME OAKS, CRAPE MIRTLES AND SILVER BUTTONWOOD
 TREES ARE PROPOSED NEAR OR OVER SOME OF THE STORM
 PIPES.
  
 7. EXISTING DRIVEWAY OPENING ON DIXIE HIGHWAY THAT WILL
 NO LONGER BE USED WILL NEED TO BE REPLACED WITH
 SIDEWALK, CURB AND GUTTER TO MATCH ADJACENT
 RIGHT-OF-WAY ITEMS.
  
 8. IT APPEARS THE DRIVEWAY ACCESS ON PALM BEACH LAKES
 BLVD IS BEING SHIFTED TO THE EAST. THE PORTION OF THE
 EXISTING DRIVEWAY THAT WILL NOT BE NEEDED FOR THE
 PROPOSED DRIVEWAY WILL NEED TO BE REMOVED AND REPLACED
 WITH STANDARD SIDEWALK, CURB AND GUTTER.
  
 9. STOP SIGNS WILL BE NEEDED AT ALL DRIVEWAYS TO PUBLIC
 RIGHTS OF WAY.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING SERVICES DEPARTMENT
 561-494-1120