| 2015-03-10 09:57:52 | PUBLIC WORKS DEPT. |
| | |
| | THIS IS A CONCEPTUAL LEVEL REVIEW. CONSTRUCTION LEVEL |
| | DETAILS, DESIGN CALCULATIONS AND THE POLLUTION |
| | PREVENTION PLAN WILL BE REVIEWED AS PART OF THE |
| | ENGINEERING DEVELOPMENT APPROVAL AND BUILDING PERMIT |
| | APPLICATION PROCESSES. THE ENGINEERING DEVELOPMENT |
| | APPROVAL APPLICATION FORMS CAN BE DOWNLOADED AT |
| | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ |
| | |
| | 1. THE SITE LAYOUT SHOWN ON SHEET SP-1 IS NOT |
| | CONSISTENT WITH THE LAYOUT SHOWN ON SHEETS SP-2. WHICH |
| | LAYOUT IS THE PROPOSED SITE CONFIGURATION? |
| | |
| | 2. WE WILL DEFER TO THE CITY'S LEGAL DEPARTMENT FOR |
| | DETERMINATION OF THE DOCUMENT REQUIRED TO DEMONSTRATE |
| | COMPLIANCE WITH SECTION 94-305(B) OF THE CODE OF |
| | ORDINANCES. "SETBACK ENCROACHMENTS. JOINT USE |
| | PROHIBITED. THE SETBACK OR OPEN SPACE OF A BUILDING ON |
| | ONE LOT SHALL NOT BE CONSIDERED AS THE SETBACK OR OPEN |
| | SPACE FOR A BUILDING ON ANY OTHER LOT EXCEPT WHERE |
| | UNITY OF TITLE IS PROVIDED FOR ALL AFFECTED |
| | PROPERTIES." |
| | |
| | 3. FLORIDA DEPARTMENT OF TRANSPORTATION APPROVAL WILL |
| | BE REQUIRED FOR THE WORK ALONG OKEECHOBEE BLVD. |
| | |
| | 4. PLEASE SUBMIT A COPY OF THE TRAFFIC CONCURRENCY |
| | LETTER FROM PALM BEACH COUNTY. |
| | |
| | 5. PLEASE SUBMIT APPLICATIONS FOR A DEVELOPMENT PERMIT |
| | AND RIGHT-OF-WAY PERMIT FROM THE ENGINEERING |
| | DEPARTMENT. APPLICATION FORMS CAN BE FOUND AT |
| | HTTP://WPB.ORG/ENGINEERING/FORMS-AND-PUBLICATIONS/ |
| | (SECTIONS 2-421 AND 78-432, CODE OF ORDINANCES) |
| | |
| | 6. PLEASE REVISE THE DRIVEWAY APRONS TO MEET THE CITY'S |
| | ENGINEERING DESIGN STANDARDS. PLEASE ALSO INCLUDE THE |
| | DETAILS FOR THE SIDEWALK RAMPS, HTTP://WPB.ORG/ENGINEER |
| | ING/ENGINEERING-SERVICES/ENGINEERING-STANDARDS/ |
| | |
| | 7. THE NUMBER OF PROPERTY ACCESS DRIVES EXCEEDS THE |
| | MAXIMUM NUMBER AND WIDTH ALLOWED FOR COMMERCIAL |
| | PROPERTIES. PER CODE OF ORDINANCES SECTION 94-313, |
| | NON-RESIDENTIAL PROPERTIES WITH LESS THAN 300 REQUIRED |
| | PARKING SPACES MAY HAVE UP TO ONE ACCESS POINT ONTO |
| | EACH RIGHT-OF-WAY. |
| | |
| | 8. PLEASE REVISE THE LANDSCAPE PLAN TO SHOW LOCATIONS |
| | OF ALL WATER METERS, VALVES, CLEAN-OUTS, LIGHT POLES, |
| | UNDERGROUND UTILITIES (WATER, SANITARY, STORM, GAS, |
| | ELECTRIC), ETC. |
| | |
| | 9. PLEASE SHOW THE SIGHT TRIANGLES ON THE LANDSCAPING |
| | PLAN FOR THE INTERSECTIONS AND VEHICULAR EXITS. |
| | (SECTION 94-305E, CODE OF ORDINANCES) |
| | |
| | 10. PLEASE REVISE PLANS TO INCLUDE THE CITY OF WEST |
| | PALM BEACH GARBAGE RECEPTACLE DETAIL. THE SHOWN DETAIL |
| | DOES NOT MEET THE MINIMUM DIMENSIONAL REQUIREMENTS OF |
| | CODE OF ORDINANCES, SECTION 94-444(B), ALSO SEE FIGURE |
| | XIV-3 OF THE SAME SECTION. CITY STANDARD DETAIL GC-8 |
| | MAY BE DOWNLOADED AT HTTP://WPB.ORG/ENGINEERING/ENGINEE |
| | RING-SERVICES/ENGINEERING-STANDARDS/ |
| | |
| | 11. WILL SOLID WASTE COLLECTION SERVICE BE PROVIDED BY |
| | THE CITY OR BY A PRIVATE COMPANY? PER SECTION 74-31 OF |
| | THE CODE OF ORDINANCES, EVERY COMMERCIAL ESTABLISHMENT |
| | WITHIN THE CITY SHALL SUBSCRIBE FOR REGULAR COMMERCIAL |
| | SOLID WASTE COLLECTION AND DISPOSAL SERVICES FROM THE |
| | CITY EXCEPT THOSE COMMERCIAL ESTABLISHMENTS FOR WHICH |
| | THE CITY IS UNABLE TO PROVIDE THE NEEDED SERVICES, |
| | E.G., CONTAINERS AND COMPACTORS OVER EIGHT CUBIC YARDS. |
| | FOR THESE SERVICES, THE COMMERCIAL ESTABLISHMENT MUST |
| | USE THE SERVICES OF A PROVIDER APPROVED TO OPERATE |
| | WITHIN THE CITY PURSUANT TO A FRANCHISE AGREEMENT. NO |
| | PERSON SHALL ATTEMPT TO USE CITY SERVICES WITHOUT |
| | HAVING FIRST SUBSCRIBED FOR SUCH SERVICES OR WITHOUT |
| | HAVING REQUESTED THE CITY TO PERFORM A SPECIAL SOLID |
| | WASTE COLLECTION AND DISPOSAL. |
| | |
| | 12. PLEASE PROVIDE AN AUTOTURN ANALYSIS DEMONSTRATING |
| | THE SOLID WASTE COLLECTION VEHICLE CAN ACCESS THE |
| | PROPOSED DUMPSTER AND COMPACTOR LOCATIONS. THE TRASH |
| | DUMPSTER/COMPACTORS MUST LOCATED IN AREAS EASILY |
| | SERVICED BY THE CITY SANITATION EQUIPMENT AND MANPOWER |
| | PER SECTION 74-35(A)(5) OF THE CODE OF ORDINANCES. |
| | |
| | 13. SOLID WASTE YARDAGE WILL NEED TO BE ESTIMATED AS |
| | PART OF THE FINAL DESIGN TO VERIFY THAT THE ENCLOSURE |
| | SIZE IS APPROPRIATE FOR THE REQUIRED NUMBER AND SIZE OF |
| | TRASH BINS. |
| | |
| | KELLY CRANFORD, PE |
| | CITY LAND DEVELOPMENT ENGINEER |
| | [email protected] |
| | 561-494-1098 (OFFICE) |
| | |
| | VINCE NOEL, PSM |
| | CITY SURVEYOR / REAL ESTATE SUPERVISOR |
| | [email protected] |
| | 561-494-1096 |
| | |
| | BRIAN COLLINS, PE |
| | CITY TRAFFIC ENGINEER |
| | [email protected] |
| | 561-494-1040 |
| | |
| | FERDINAND RIVERA |
| | PUBLIC WORKS OPERATIONS MANAGER |
| | [email protected] |
| | 561-822-2076 |
| | |
| | TRACY WARD, PE |
| | CITY STORMWATER ENGINEER |
| | 561-494-1120 |
| | [email protected] |
| | |
| |