Plan Review Notes
Plan Review Notes For Project Z15010030
Project Number Z15010030
Review Stop Z
Sequence Number 2
Notes
Date Text
2015-04-16 17:02:431.PROJECT DATA SHALL BE REVISED TO INCLUDE FAR
 CALCULATIONS.
 2. THE MAJORITY OF THE SPACES INDICATED ON SHEET A-601
 AS QUALIFIED PUBLIC OPEN SPACES DO NOT MEET THE POS
 REQUIREMENTS. THE PUBLIC OPEN SPACE IS INTENDED TO
 CREATE A GATHERING PUBLIC SPACE SUCH AS A PLAZA OR
 PARK. IT IS NOT INTENDED TO BE GENERAL CIRCULATION
 AREAS.
 3. COMPLIED.
 4. COMPLIED
 5. PLEASE LOOK AT THE FOOTPRINT DEFINITION. FOOTPPINT
 IS CALCULATED BASICALLY AS THE AREA COVERED BY A ROOF
 ON EACH LEVEL, NOT NECESSARILY ENCLOSED, BUT COVERED.
 6. THE MAXIMUM FOOTPRINT LENGHT FOR THIS DISTRICT IS
 350 FEET, INCLUDING A MINIMUM OF 60 FEET SEPARATION
 BETWEEN PODIUM ELEMENTS. PROPOSED PROJECT DOES NOT
 COMPLY WITH THIS PROVISION. FURTHER DISCUSSION WILL BE
 NECESSARY TO DETERMINE IF THE DAC CAN APPROVED THE
 FOOTPRINT SEPARATION TO BE LOCATED AT THE ROOF TOP DECK
 LEVEL OR A CODE AMENDMEN.
 7. DAC APPROVAL WILL BE REQUIRED TO ALLOW CURB CUTS
 THAT EXCEED THE MAXIMUM 25 FEET WIDTH PERMITTED.
 8. PROPOSED DROP-OFF AND PASSENGER LOADING FOR HOTEL
 AND RESIDENTIAL USE DOES NOT COMPLY WITH CODE
 REQUIREMENTS IN SEC 94-109.
 9. AT THIS POINT THE PARKING GARAGE DOES NOT INCLUDE
 ANY STRUCTURAL ELEMENTS. PLEASE BE AWARE THE WIDTH OF
 THE PARKING SPACES IS LARGER IF STRUCTURAL ELEMENTS ARE
 ADJACENT TO THE SPACE. DEAD END PARKING AREAS SHALL
 HAVE A TURN AROUND SPACE.
 10. ADDITIONAL DETAIL WILL BE REQUIRED FOR THE LOCATION
 OF THE BIKE FACILITIES. EXACT DIMENSION OF THE SPACE
 AND LOCATION OF RACKS SHALL BE PROVIDED TO CONFIRM
 COMPLIANCE.
 11. OK.
 12. PLEASE CONTACT SYBILLE WALTER TO START THE ART IN
 PUBLIC PLACES PROCESS AS SOON AS POSSIBLE. THE PROJECT
 WILL BE REQUIRED TO DEDICATE 1% OF THE CONSTRUCTION
 COST FOR AN ART IN PUBLIC PLACES. SOME OF THE ART
 INSTALLATIONS MAY QUALIFIED BUT THEY REQUIRE APPROVAL
 BY THE AIPP COMMITTEE AND THE CITY COMMISSION.
 13. COMPLIANCE WITH PUBLIC OPEN SPACE SHALL BE REVISED.
 14. ADDITIONAL INFORMATION SHALL BE PROVIDED TO COMFIRM
 COMPLIANCE WITH THE FACADE ARTICULATION. THE FLOOR
 PLANS DO NOT INDICATE ANY OF THE DETAILS SHOWN ON THE
 FACADES.
 15. FURTHER DISCUSSION NECESSARY. PUBLIC OPEN SPACE
 INDICATED IN THE FIRST FLOOR DOES NOT QUALIFY.
 16.FURTHER DISCUSSION NECESSARY.
 17. IS THE BRIDGE TO THE TRAIN STATION AT THE 2ND LEVEL
 OF THE TRANSIT VILLAGE? IS IT LOCATED AT THE SAME
 ELEVATION? PLEASE SHOW HOW THE CONNECTION BETWEEN THE
 TRI-RAIL BRIDGE AND THE DECK IS PROPOSED.
 18. OK.
 19. MORE DETAIL NECESSARY.
 20. OK.
 21. SEE COMMENT NO. 12.
 22-26- RENDERINGS WILL BE REQUIRED FOR THE DAC SPECIAL
 REVIEW, AS WELL AS MORE DETAIL ON THE BUILDING DESIGN,
 FACADE ARTICULATION, LOCATION OR DOORS, WINDOWS ETC.
 27-30. SEE LANDSCAPE COMMENTS.
  
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.
  
  