| 2014-12-11 10:58:27 | PLANS AND PLATS REVIEW COMMITTEE (PPRC) ZONING REVIEW |
| | ___________________________________________ |
| | |
| | DATE OF REVIEW: DECEMBER 10, 2014 |
| | PROJECT NO.: Z14110031 AND Z14110032 |
| | CASE NO.: PB CASE NO. 1624E AND F |
| | ADDRESS: 3100-3200 CONGRESS AVENUE |
| | APPLICANT/CONTACT: JONI BRINKMAN, URBAN DESIGN KILDAY |
| | STUDIOS |
| | TELEPHONE NO.: 561.366.1100 |
| | SCOPE OF REVIEW: MAJOR PD AMENDMENT (HOTEL) AND MAJOR |
| | SUBDIVISION |
| | ___________________________________________ |
| | |
| | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING |
| | REVIEW COMMENTS: |
| | |
| | 1. AS A FOLLOW UP TO YOUR EMAIL, FEES WILL NEED TO BE |
| | PROVIDED FOR THE ADDITIONAL MAJOR SUBDIVISIONS. IN THE |
| | END, I BELIEVE THERE WILL BE 3 TOTAL SUBDIVISION |
| | APPLICATIONS (1 FOR OVERALL PLAT + 1 FOR POD L1 + 1 FOR |
| | POD L2). |
| | |
| | 2. WHAT HAS OCCURRED TO DATE, AND WHAT IS PLANNED, |
| | REGARDING OUTREACH TO THE SURROUNDING ASSOCIATIONS? |
| | PRIOR TO PUBLIC HEARING, THE PROPOSED PLAN SHALL BE |
| | PRESENTED TO THE SURROUNDING ASSOCIATIONS FOR COMMENT, |
| | QUESTIONS, ETC. |
| | |
| | 3. A REVISED TRAFFIC CONCURRENCY LETTER SHALL BE |
| | PROVIDED BY PALM BEACH COUNTY. |
| | |
| | 4. PLEASE PROVIDE UPDATED LETTERS FROM ALL OF THE |
| | UTILITY COMPANIES REGARDING THE PROPOSED SITE PLAN. |
| | |
| | 5. PLEASE PROVIDE A SIGNED/NOTARIZED AFFIDAVIT |
| | REGARDING THE MAILING LIST (SEE PAGE 20 OF THE |
| | DEVELOPMENT APPLICATION). |
| | |
| | 6. PLEASE PROVIDE A STRIKETHROUGH AND UNDERLINED |
| | VERSION OF THE DESIGN GUIDELINES TO INDICATE THOSE |
| | AREAS WHERE MODIFICATIONS ARE PROPOSED. |
| | |
| | 7. THERE NEEDS TO BE CLEARER DEFINITION IN THE PLANS |
| | BETWEEN THE DIFFERENT PODS/PBAS. FOR CODE COMPLIANCE, |
| | ETC. A SITE PLAN AND LANDSCAPE PLAN SHOULD BE PREPARED |
| | FOR EACH PBA, WITH EACH PBA MEETING THE MINIMUM CODE |
| | REQUIREMENTS OF THE CITY?S ZLDRS AND/OR THE DESIGN |
| | GUIDELINES. IF IT IS PREFERRED THAT EACH PBA NOT STAND |
| | ALONE AND MEET THE MINIMUM CODE REQUIREMENTS, THEN AN |
| | OVERALL SITE AND LANDSCAPE PLAN WOULD HAVE TO BE |
| | PREPARED WHICH SHOWS COMPLIANCE ACROSS THE ENTIRE SITE. |
| | |
| | 8. SITE PLANS FOR EACH POD/PBA SHALL PROVIDE A SITE |
| | DATA TABLE INDICATING COMPLIANCE WITH THE CITY?S ZLDRS |
| | AND THE PD DESIGN GUIDELINES. FOR EXAMPLE, MAXIMUM FAR |
| | IS SHOWN, BUT IT IS NOT IDENTIFIED AS WHAT IS PROVIDED. |
| | WITHIN THE CPD, FAR SHALL INCLUDE ALL NON-RESIDENTIAL |
| | AND RESIDENTIAL USE SQUARE FOOTAGES. |
| | |
| | 9. ARE THE SIGNS LABELED AT THE ENTRANCES TO EACH |
| | SINGLE FAMILY POD THE ENTRANCE SIGNS IDENTIFIED IN THE |
| | DETAIL ON SHEET SP-4? IF SO, PLEASE INDICATE SUCH ON |
| | THE SITE PLAN. |
| | |
| | 10. THERE ARE A LOT OF AREAS WHERE PLANS WERE NOT |
| | PROVIDED FOR. EXAMPLES INCLUDE LANDSCAPING FOR THE |
| | TENNIS CENTER, THE PARKING IN POD C2, PERIMETER |
| | BUFFERS, ETC. |
| | |
| | 11. THE LANDSCAPE PLANS FOR THE HOTEL SITE OVERLAP WHAT |
| | HAS BEEN DRAWN FOR THE ECO-VILLAS, AND THEY DON?T |
| | MATCH. |
| | |
| | 12. THE POD LINES ON THE MASTER PLAN DO NOT APPEAR TO |
| | MATCH WHAT IS SHOWN ON THE SITE PLANS. ENSURE THAT ALL |
| | PLANS ARE CONSISTENT. |
| | |
| | 13. THERE NEEDS TO BE MORE CLARITY IN THE SITE PLANS. |
| | THERE ARE LINE TYPES THAT ARE NOT IDENTIFIED, |
| | UNREADABLE, ETC. PROPERTY LINES AND PHYSICAL |
| | IMPROVEMENTS SHOULD BE MOST PROMINENT (BUILDINGS, |
| | SIDEWALKS, PATHS, ROADWAYS, PARKING, ETC.). UTILITIES, |
| | EASEMENTS, PBA BOUNDARIES, ETC. SHOULD BE LESS |
| | PROMINENT. |
| | |
| | 14. WHAT IS THE DASHED LINE THAT RUNS THROUGH THE |
| | DRIVING RANGE, CLUBHOUSE, PARKING LOT, AND TENNIS |
| | COURTS? |
| | |
| | 15. THE 12 FOOT FPL EASEMENT CROSSING POD D, POD C1, |
| | POD R, AND POD C2 IS NOT SHOWN ON THE SITE/LANDSCAPE |
| | PLAN. |
| | |
| | 16. THE PHASE 2 PARKING STRUCTURE IS SHOWN OVER A |
| | UTILITY EASEMENT. |
| | |
| | 17. THE LANDSCAPE PLAN FOR POD R, L1, AND L2 IS |
| | MISLABELED AS ?RESORT AND MULTIFAMILY STREETSCAPE?. |
| | THIS PLAN DOES INCLUDE STREETSCAPE FOR SINGLE FAMILY. |
| | ADDITIONALLY, THIS STREETSCAPE PLAN IS |
| | INSUFFICIENT/INCOMPLETE. |
| | |
| | 18. STAFF CONTINUES TO HAVE ISSUES WITH THE DESIGN OF |
| | THE AREA AND PROPOSED CUL-DE-SAC ADJACENT TO LOT 1 OF |
| | POD L2, AND THE LACK OF CONNECTIVITY. |
| | |
| | 19. THE CLUBHOUSE IS SHOWN ON TOP OF AN FPL EASEMENT. |
| | |
| | 20. SIDEWALKS SHALL BE PROVIDED ON BOTH SIDES OF ALL |
| | STREETS. EXCEPTIONS MAY BE MADE FOR THE STREETS IN |
| | FRONT OF THE HOMES IN POD L2 (LOTS 19-30) AND POD L1. |
| | THE SIDEWALKS IN THESE AREAS NEED TO BE WITHIN THE |
| | DEDICATED STREET. |
| | |
| | 21. CROSSWALKS SHALL BE PROVIDED ACROSS POD R TO |
| | CONNECT POD L2 TO POD L1. |
| | |
| | 22. THE PLANS SHALL INDICATE PAVEMENT MARKINGS, |
| | SIGNAGE, DIMENSIONS OF ROADWAYS/DRIVEWAYS, ETC. |
| | |
| | 23. I DON?T BELIEVE THE ECO-VILLAS (PBA #5) SHOULD BE |
| | SUBJECT TO THE ZERO-LOT LINE PROVISIONS PROVIDED WITHIN |
| | THE DESIGN GUIDELINES. PBA #5 HAS BEEN LISTED IN THE |
| | ZERO-LOT LINE REGULATIONS, AS WELL AS THE MULTIFAMILY |
| | REGULATIONS. |
| | |
| | 24. 180 FEET SHOULD BE MAINTAINED BETWEEN POD L3 AND |
| | THE WESTERN-MOST PLATTED LOT LINE OF THE EXISTING |
| | SINGLE FAMILY ON EMBASSY DRIVE. ADDITIONALLY, THE 230 |
| | FEET OF SEPARATION BETWEEN BUILDINGS SHOULD BE |
| | MAINTAINED. |
| | |
| | 25. A 10 FOOT LANDSCAPE BUFFER NEEDS TO BE PROVIDED ON |
| | THE EAST SIDE OF THE PRESIDENTIAL WAY ACCESS DRIVE. THE |
| | INGRESS/EGRESS EASEMENT SHOULD BE RELOCATED TO |
| | ACCOMMODATE THIS LANDSCAPE BUFFER, AND THE EASEMENT |
| | WILL NEED TO BE WIDENED TO MATCH THE WIDTH OF THE |
| | ACCESS DRIVE. |
| | |
| | 26. PLEASE EXPLAIN THE PROPOSED LOT CONFIGURATION FOR |
| | PODS L1 AND L2. DO THE LOTS FRONT ONTO A DEDICATED |
| | STREET? NO STREET NAMES AND NO INFORMATION HAS BEEN |
| | SHOWN ON THE PLATS. ADDITIONALLY, THE STREETS IN FRONT |
| | OF THE HOMES SHALL NOT DEAD-END UNLESS AN OPEN SPACE |
| | WITH A RADIUS OF 50 FEET IS PROVIDED. THE STREETS IN |
| | FRONT OF THE HOMES ARE TO HAVE A DEDICATION THAT IS AT |
| | LEAST 40 FEET IN WIDTH. |
| | |
| | 27. LOT 1 ON PLAT L2 IS NOT LABELED. |
| | |
| | 28. PROVIDE DETAILS REGARDING THE SCREENING AND THE |
| | LANDSCAPING AROUND THE LIFT STATION. |
| | |
| | 29. STREET LIGHTS ARE SHOWN WITHIN THE BOUNDARY OF THE |
| | PHASE 2 PARKING GARAGE. |
| | |
| | 30. STREET LIGHTS ARE SHOWN UNDER PARKING STRUCTURE 1. |
| | |
| | 31. THE SITE PLAN SHOULD REFLECT THE SHARED PARKING |
| | CALCULATION PROVIDED BY PINDER TROUTMAN CONSULTING, |
| | INC. |
| | |
| | 32. PURSUANT TO THE PARKING CALCULATION PROVIDED BY |
| | PINDER TROUTMAN CONSULTING, INC., 407 PARKING SPACES |
| | SHALL BE PROVIDED (NOT INCLUDING THE 51 RESORT |
| | COTTAGES). ACCORDING TO THE SITE PLAN, ONLY 400 PARKING |
| | SPACES ARE PROVIDED (NOT INCLUDING THE PHASE 2 |
| | STRUCTURE). THEREFORE, THE PHASE 2 STRUCTURE NEEDS TO |
| | BE INCLUDED AS PART OF THE INITIAL CONSTRUCTION OR |
| | ADDITIONAL PARKING NEEDS TO BE PROVIDED. |
| | |
| | 33. DETAILS NEED TO BE PROVIDED REGARDING ALL PROPOSED |
| | FENCING AND WALLS, INCLUDING THAT AT THE TENNIS COURTS. |
| | |
| | 34. ALL POOLS ARE TO BE ENCLOSED BY A FENCE OR SIMILAR |
| | STRUCTURE THAT IS AT LEAST FOUR (4) FEET IN HEIGHT. |
| | PLANS ARE UNCLEAR AS TO WHETHER OR NOT THIS PROVISION |
| | IS BEING MET. |
| | |
| | 35. ARE CARTS GOING TO BE UTILIZING SIDEWALKS? THERE |
| | ARE SEVERAL LOCATIONS WHERE THE SIDEWALKS ARE AT |
| | SIGNIFICANT ANGLES THAT PROBABLY COULD NOT BE |
| | MANEUVERED BY A GOLF CART. CONSIDERATION SHOULD BE MADE |
| | REGARDING USAGE OF THE PATHS AND SIDEWALKS. |
| | |
| | 36. BIKE RACKS SHALL BE PROVIDED AT EACH FACILITY. |
| | PLEASE PROVIDE A DETAIL (CONTACT ME FOR ACCEPTABLE |
| | DESIGNS). PARKING FOR BIKES SHALL BE PROVIDED AT A |
| | RATIO OF 1 SPACE PER 20 AUTOMOBILE SPACES. |
| | |
| | 37. THE PARKING SPACES BY THE CLUBHOUSE NEED TO PROVIDE |
| | 24 FEET OF BACK-OUT. |
| | |
| | 38. THE ACCESSIBLE PARKING SPACE AT THE NORTH END OF |
| | PARKING STRUCTURE 1 NEEDS TO PROVIDE 24 FEET OF |
| | BACK-OUT. |
| | |
| | 39. PLANS SHALL BE PROVIDED FOR THE PARKING STRUCTURES. |
| | THE PARKING CONFIGURATION SHOWN ON THE SITE PLAN DOES |
| | NOT ACCOUNT FOR ANY RAMPS, ETC. ADDITIONALLY, THE |
| | DESIGN GUIDELINES PROVIDE THAT THE UPPER LEVEL OF |
| | PARKING WILL BE COVERED AND LANDSCAPED OR OTHERWISE |
| | ENHANCED. |
| | |
| | 40. THE FLOOR PLAN FOR THE HOTEL SHOWS AN ADDITIONAL |
| | RESTAURANT OF ALMOST 4,000 SQUARE FEET. THIS WAS NOT |
| | ACCOUNTED FOR IN ANY OF THE CALCULATIONS. |
| | |
| | 41. THE FLOOR PLAN FOR THE RESTAURANT INDICATES THAT |
| | THERE IS MORE THAN 6,000 SQUARE FEET. PLEASE NOTE THAT |
| | OUTDOOR DINING/BAR AREA SHALL COUNT TOWARDS ALL |
| | CALCULATIONS (PARKING, TRAFFIC, ETC.). |
| | |
| | 42. THE PROPOSED DESIGN GUIDELINES HAVE PBA #5 |
| | (ECO-VILLAS) WITH A MAXIMUM BUILDING HEIGHT OF 40 FEET. |
| | I THINK THIS SHOULD BE REDUCED TO REFLECT WHAT IS |
| | PROPOSED. |
| | |
| | 43. THE PROPOSED DESIGN GUIDELINES HAVE PBA #4 (HOTEL) |
| | AS BEING A MAXIMUM BUILDING HEIGHT OF 3 STORIES. |
| | ACCORDING TO THE ARCHITECTURAL PLANS, THE HOTEL IS |
| | PROPOSED TO BE 4 STORES. |
| | |
| | 44. PLEASE PROVIDE THE BUILDING HEIGHTS OF ALL |
| | BUILDINGS, AS DEFINED BY THE CITY?S ZLDRS. |
| | |
| | 45. THE ELEVATIONS SHOWN FOR THE ECO-VILLAS DO NOT |
| | MATCH THE FLOOR PLAN. |
| | |
| | 46. BUILDING MATERIALS NEED TO BE SPECIFIED TO ENSURE |
| | COMPLIANCE WITH THE DESIGN GUIDELINES. |
| | |
| | 47. THE SITE AND LANDSCAPE PLANS SHALL IDENTIFY THE |
| | LOCATION OF ALL MECHANICAL EQUIPMENT FOR ALL BUILDINGS, |
| | AS WELL AS PROVIDE THE REQUIRED SCREENING. |
| | |
| | 48. A SCREEN WALL SHALL BE PROVIDED AROUND THE |
| | PERIMETER OF THE SERVICE/LOADING AREA, AND SHALL BE |
| | DESIGNED IN ACCORDANCE TO THE REQUIREMENTS OF THE |
| | DESIGN GUIDELINES. |
| | |
| | 49. NO LIGHTING IS BEING PROVIDED ON THE TENNIS COURTS? |
| | IF SO, THIS SHALL BE PROVIDED WITHIN THE PHOTOMETRIC |
| | PLANS. LIGHTING LEVELS SHALL BE PROVIDED AT ALL POINTS |
| | ALONG THE BOUNDARY OF THE RPD/CPD. |
| | |
| | 50. PLEASE CONFIRM THAT ALL LIGHTS ARE FULL CUT-OFF. |
| | |
| | 51. THERE NEEDS TO BE A 5 FOOT SIDEWALK CONNECTING THE |
| | PRESIDENTIAL WAY ACCESS POINT TO THE INTERNAL |
| | CIRCULATION NETWORK. |
| | |
| | 52. THERE NEEDS TO BE BETTER CONNECTIVITY BETWEEN THE |
| | TENNIS CENTER AND THE REST OF THE INTERNAL CIRCULATION |
| | NETWORK. |
| | |
| | 53. THERE NEEDS TO BE BETTER CONNECTIVITY BETWEEN THE |
| | CLUBHOUSE AND THE HOTEL. |
| | |
| | 54. ALONG THE MAIN ROADS, THE SIDEWALK SHOULD BE PULLED |
| | AWAY FROM THE CURB AND CREATE A PARKWAY THAT PROVIDES |
| | THE LIGHTING, TREES, ETC. |
| | |
| | 55. AN ENLARGED SITE PLAN NEEDS TO BE PROVIDED FOR THE |
| | GREAT LAWN AREA. THIS WAS ONLY SHOWN ON THE OVERALL |
| | SITE PLAN. |
| | |
| | 56. IN SEVERAL LOCATIONS, THE LANDSCAPE PLAN FOR THE |
| | ECO-VILLAS SHOWS TREES BEING PLANTED ON TOP OF CART |
| | PATHS/SIDEWALKS. |
| | |
| | 57. THERE IS A DRAINAGE EASEMENT SHOWN ON THE MASTER |
| | PLAN CUTTING THROUGH THE DEVELOPMENT THAT IS NOT SHOWN |
| | ON THE PLATS OR SITE PLANS. |
| | ___________________________________________ |
| | |
| | PLEASE NOTE THE FOLLOWING WHEN RESUBMITTING: |
| | |
| | A) WRITTEN RESPONSES TO COMMENTS MADE BY ALL |
| | DEPARTMENTS SHALL BE PROVIDED UPON RESUBMISSION. |
| | |
| | B) 15 SETS OF REVISED PLANS AND/OR DOCUMENTS SHALL BE |
| | PROVIDED, ALONG WITH ONE (1) REDUCED COPY (11IN X |
| | 17IN), AND AN ELECTRONIC COPY OF ALL PLANS. |
| | |
| | C) PLEASE NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO |
| | ADDITIONAL COMMENTS. |
| | |
| | D) IF NO RESPONSE IS RECEIVED WITHIN 60 DAYS OF THE |
| | ISSUANCE OF THESE COMMENTS, THE APPLICATION WILL BE |
| | CONSIDERED WITHDRAWN AND ANY FURTHER ACTION WILL |
| | REQUIRE SUBMISSION OF A NEW DEVELOPMENT APPLICATION. |
| | |
| | E) PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE |
| | WILL BE 20% OF THE ORIGINAL APPLICATION FEE. |
| | |
| | F) IN ORDER TO BE CONSIDERED FOR THE JANUARY 21, 2015 |
| | PLANNING BOARD AGENDA, ALL COMMENTS SHALL BE |
| | SATISFACTORILY ADDRESSED. PLEASE SUBMIT ALL REVISED |
| | DOCUMENTS/PLANS NO LATER THAN FRIDAY, DECEMBER 19, |
| | 2014. |
| | |
| | G) TO BE PLACED ON THE JANUARY 21, 2015 PLANNING BOARD |
| | AGENDA, SIGNS SHALL BE POSTED ON THE PROPERTY NO LATER |
| | THAN JANUARY 6, 2015. SIGNAGE SHALL CONFORM AND BE |
| | INSTALLED WITH THE REQUIREMENTS OF THE CITY?S ZONING |
| | AND LAND DEVELOPMENT REGULATIONS, AS ALSO PROVIDED IN |
| | THE DEVELOPMENT APPLICATION. A SIGNED AND NOTARIZED |
| | AFFIDAVIT SHALL BE PROVIDED BY THE DEADLINE REFERENCED |
| | ABOVE. |
| | ___________________________________________ |
| | |
| | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: |
| | |
| | JOHN ROACH, PRINCIPAL PLANNER |
| | CITY OF WEST PALM BEACH |
| | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION |
| | 401 CLEMATIS STREET - P.O. BOX 3147 |
| | WEST PALM BEACH, FLORIDA 33402 |
| | |
| | PHONE: 561.822.1448 |
| | FAX: 561.822.1460 |
| | |
| | EMAIL: [email protected] |
| | |
| | WWW.WPB.ORG |
| | |
| |
Print |