| 2014-04-04 11:44:09 | 1. PROPOSED COURTYARD IS NOT CURRENTLY PERMITTED IN THE |
| | CWD-CD. STAFF SUGGEST A CODE AMENDMENT TO ALLOW THE |
| | PROPOSED COURTYARD. |
| | 2. A PASSGEWAY IS REQUIRED FOR THE CWD-10. PROPOSED |
| | PASSAGEWAY DOES NOT COMPLY WITH CODE REQUIREMENTS FOR |
| | PASSAGEWAY INTENDED FOR PEDESTRIAN CIRCULATION. |
| | ADDITIONAL DISCUSSION WILL BE NECESSARY TO DETERMINE |
| | ALTENATIVE OPEN SPACES. |
| | 3.PLEASE PROVIDE INFORMATION REGARDING COMPLIANCE WITH |
| | PRIVATE OPEN SPACE REQUIREMENT (LA AND HARDSCAPE |
| | DRAWINGS REQUIRED). TABLE INDICATING AMOUNT OF |
| | VEGETATED AREA, AND TREE CANOPY REQUIRED VS PROVIDED. |
| | 20% OF SITE AS TERRACE ON TOP OF 2ND STORY. |
| | 4.PLEASE PROVIDE DETAIL INFORMATION ABOUT THE PROPOSED |
| | BRIDGE OVER THE ALLEY ROW. |
| | 5. PROPOSED BULB OUT ON CLEMATIS STREET SHALL BE |
| | REMOVED. CLEMATIS STREETSCAPE SHALL BE MAINTAINED |
| | CONSISTENT WITH THE EXISTING. REMOVED PROPOSED GREEN |
| | ISLAND FICUS. |
| | 6. PLEASE INDICATE THE DIMENSION OF SETBACK ON DATURA |
| | STREET. |
| | 7. PLEASE INDICATE THE PROPERTY LINE AND SETBACK LINE |
| | ON ALL FLOOR PLANS AND ELEVATIONS. |
| | 8. PLEASE PROVIDE A GROSS BUILDING AREA TABLE AND AN |
| | ASSOCIATED GRAPHIC FOR EACH FLOOR INDICATING THE AREA |
| | CALCULATED FOR FAR AND EXCLUDED ON EACH FLOOR. USE |
| | DEFINITION OF GROSS BUILDING AREA IN SECTION 94-109. |
| | 9. PLEASE PROVIDE A DEVELOPEMENT CAPACITY VS PROPOSED |
| | DEVELOPEMENT TABLE INDICATING THE AREA AND FAR OF EACH |
| | PARCEL. |
| | 10.PLEASE PROVIDE COLORED ELEVATIONS (ASSIGN |
| | TRANSPARENCY TO STREET TREES), AND INDICATE MAIN |
| | MATERIALS, BUILDING HEIGHTS, SETBACK AND PROPERTY |
| | LINES. |
| | 11. PLEASE INSERT COLOR ELEVATION IN THE STREET CONTEXT |
| | FOR EACH STREET FRONTAGE. |
| | 12. WHAT ARE THE POSSIBILITIES TO BURY THE OVERHEAD |
| | ELECTRIC LINES ON DATURA STREET? PROPOSAL RELOCATES THE |
| | EXISTING POLES TO THE CITY ROW. FURTHER DISCUSSION ON |
| | ALTERNATIVES IS NECESSARY. |
| | 13. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE |
| | WITH TABLE IV-4: FACADE ARTICULATION REQUIREMENTS. |
| | 14. PLEASE PROVIDE AUTO-TURN TO DEMONSTRATE LOADING |
| | AREA OPERATION. |
| | 15. PLEASE STUDY THE OPTION TO NARROW THE ALLEY EXIT |
| | INTO ROSEMARY AVE TO REDUCE THE NEGATIVE IMPACT ON |
| | PEDESTRIAN CIRCULATION. |
| | 16. PLEASE DISCUSS THE POSSIBILITY TO RELOCATE THE BACK |
| | FLOW PREVENTORS TO THE ALLEY. THEY SHALL NOT BE LOCATED |
| | ON THE PRIMARY STREET IF THERE ARE OTHER OPTIONS. |
| | 17. LP-1 SHOWS AN OAK AT THE ROSEMARY AVE/DATURA STREET |
| | CORNER, A-1 SHOWS A FOUNTAIN. |
| | 18. DATURA STREETSCAPE SHALL BE CONSISTENT. SHADE TREES |
| | SHALL BE PROVIDED (OAKS ARE PLANTED ALONG 610 CLEMATIS |
| | BUILDING). TREE GRATES SHALL BE INSTALLED ADJACENT TO |
| | THE CURB. |
| | 19. EXISTING TREES ALONG ROSEMARY AVENUE SHALL BE |
| | EVALUATED TO DETERMINE IF REPLACEMENT IS NEEDED. |
| | 20. ROSEMARY AVENUE PAVERS SHALL NOT CONTINUE ALONG |
| | DATURA STREET. |
| | 21. PLEASE CLARIFY WHAT ARE THE ARCHITECTURAL COLUMNS |
| | INDICATED IN HP-1. |
| | 22. CLEMATIS PLAZA SHALL HAVE THE SAME PAVERS CURRENTLY |
| | INSTALLED ALONG CLEMATIS STREET. |
| | 23. PLEASE CORRECT PARKING TABLE (MAX PARKIGN ALLOWED |
| | FOR RETAIL). |
| | 24. PLEASE INDICATE PARKING DIMENSIONS (AISLE+SPACES). |
| | CONSIDER WIDER STALL REQUIRED WHEN COLUMNS PRESENT. |
| | 25. PLEASE INDICATE CIRCULATION PATTER IN GARAGE. |
| | 26. PLEASE INDICATE LOCATION OF HANDICAP SPACES AND |
| | GUEST PARKING. |
| | 27. TANDEM SPACES FOR RESIDENTIAL USES SHALL BE |
| | ASSIGNED TO UNE SINGLE UNIT AND RESTRICTIVE COVENANT |
| | WILL BE REQUIRED. TANDEM FOR COMMERCIAL WILL COUNT AS 1 |
| | SPACE UNLESS VALET PARKING IS PROVIDED, AND RESTRICTIVE |
| | COVENANT WILL BE REQUIRED. |
| | 28.PLEASE PROVIDE REQUIRED BIKE PARKING FOR COMMERCIAL |
| | AND RESIDENTIAL USES. COMMERCIAL (5 SPACES + ONE |
| | SHOWER/CHANGING FACILITY) RESIDENTIAL (12 SPACES). |
| | 29. PLEASE INDICATE LOCATION OF DUMPSTER FOR GARBAGE. |
| | 30.PLEASE PROVIDE INFORMATION ABOUT PROPOSED STRUCTURES |
| | ON ROOF TOP (HEIGHT, USES) COMPLIANCE WITH TABLE IV-5. |
| | 31. PLEASE PROVIDE INFORMATION ON COMPLIANCE WITH BLANK |
| | WALL REGULATIONS. |
| | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA |
| | APONTE AT 561-822-1439 |
| |