| Date |
Text |
| 2014-03-11 20:33:08 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, |
| | COMMENTS: |
| | |
| | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE |
| | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH |
| | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE |
| | ADDRESSED FOR PERMITTING. |
| | |
| | 2. PROXIMITY OF ACCESSIBLE PARKING. THE SURVEY DRAWING |
| | AND CIVEL ENGINEERING SHEETS C-1 AND C-2 SHOW THE |
| | ACCESSIBLE PARKING SPACES LOCATED SUCH THAT THEY ARE |
| | THE CLOSEST PARKING SPACES TO THE BUILDING ENTRANCE. |
| | SHEETS MP1.0, SP1.0 AND A1.0S ALL SHOW THE PROPOSED |
| | ACCESSIBLE PARKING SPACES FURTHER FROM THE BUILDING |
| | ENTRANCE SUCH THAT THEY WOULD NO LONGER BE THE CLOSEST |
| | PARKING SPACES TO THE BUILDING ENTRANCE. PER SECTION |
| | 208.3 OF FLORIDA ACCESSIBILITY CODE ACCESSIBLE PARKING |
| | SPACES ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE |
| | OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE |
| | ENTRANCE FOR EACH BUILDING. THE DESIGN OF ACCESSIBLE |
| | PARKING SPACES SHALL COMPLY WITH SECTION 502 OF FLORIDA |
| | ACCESSIBILITY CODE |
| | |
| | 3. CONSTRUCTION TYPE. WHEN SUBMITTED FOR BUILDING |
| | PERMIT, THE PLANS SHALL SHOW THAT THE TYPE OF |
| | CONSTRUCTION FOR THE BUILDINGS WILL BE IN ACCORDANCE |
| | WITH THE HEIGHT, AREA AND OCCUPANCY LIMITATIONS IN |
| | CHAPTER 5 OF THE FLORIDA BUILDING CODE |
| | |
| | 4. BUILDING SEPARATION. WHEN SUBMITTED FOR BUILDING |
| | PERMIT, COMPLIANCE WITH ALL BUILDING SEPARATION, |
| | PERCENTAGE OF OPENINGS AND OPENING PROTECTIVE |
| | REQUIREMENTS OF CHAPTERS 6 AND 7 OF THE FLORIDA |
| | BUILDING CODE SHALL BE VERIFIED. |
| | |
| | 5. ADDITION TO EXISTING BUILDING. THE ADDITION TO THE |
| | EXISTING BUILDING IS COVERED BY CHAPTER 10 OF THE |
| | FLORIDA EXISTING BUILDING CODE. THE HEIGHT AND/OR AREA |
| | INCREASE DUE TO THE PROPOSED ADDITION SHALL NOT |
| | INCREASE THE TOTAL BUILDING HEIGHT AND/OR AREA BEYOND |
| | THAT ALLOWED UNDER THE APPLICABLE PROVISIONS OF CHAPTER |
| | 5 OF THE FLORIDA BUILDING CODE FOR THE TYPE OF |
| | CONSTRUCTION USED. |
| | |
| | 6. ALL APPLICABLE PERMITS AND SUB-PERMITS MUST BE |
| | OBTAINED BEFORE COMMENCING THE WORK. |
| | |
| | ROBERT BROWN |
| | BUILDING OFFICIAL |
| | TEL: 561 805 6652 |
| | EMAIL: [email protected] |
| | |
| |
Print |