| Plan Review Notes For Project Z13120017 |
| Project Number |
Z13120017 |
|
| Review Stop |
STORM |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2014-01-08 12:37:02 | 1. PROVIDE COPY OF SFWMD ERP PERMIT MODIFCATIONBEFORE | | | START OF CONSTRUCTION. | | | 2. PROVIDE COPY OF NPDES NOI BEFORE START OF | | | CONSTRUCTION. | | | 3. PROVIDE SIGNED AND SEALED SWPPP AND PGD PLANS WITH | | | ENGINEERING PERMIT APPLICATION. | | | 4. PROVIDE SIGNED AND SEALED DRAINAGE CALCULATIONS WITH | | | ENGINEERING PERMIT APPLICATION. | | | 5. ONLY CONCEPTUAL ENGINEERING PLAN SUBMITTED. | | | 6. WHAT PART OF STORMWATER MANAGEMENT SYSTEM CURRENTLY | | | EXISTS? WILL ANY OF THE EXISTING DRAINAGE SYSTEM BE | | | REMOVED/ABANDONED? | | | 7. AVOID PLANTING OF TREES WITHIN 5 FEET OF UNDERGROUND | | | UTILITIES. | | | 8. MINIMIZE THE NUMBER OF OUTFALLS INTO THE PRESERVE. | | | 9. INCORPORATE BAFFLES AND SEDIMENT SUMPS IN THE | | | DRAINAGE STRUCTURES TO PREVENT OFFISITE DISCHARGE OF | | | POLLUTANTS, SEDIMENTS AND FLOATABLES. | | | 10. DETAILS FOR CONTROL STRUCTURES AND EXFILTRATION | | | TRENCHES WILL BE REQUIRED WITH THE ENGINEERING PERMIT | | | APPLICATION. | | | | | | TRACY L. WARD, P.E. | | | SENIOR STORMWATER ENGINEER | | | ENGINEERING AND PUBLIC WORKS DEPARTMENT | | | 561-494-1120 | | | |
| |