Plan Review Notes
Plan Review Notes For Project Z13120013
Project Number Z13120013
Review Stop Z
Sequence Number 2
Notes
Date Text
2014-05-28 17:46:42ZONING COMMENTS
  
 *PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 *WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF TEN
 (10) COPIES, ONE (1) REDUCED COPY (8 ? BY 11), AND AN
 ELECTRONIC COPY IN .PNG FORMAT OF ALL PLANS. PLEASE
 NOTE THAT RE-SUBMITTALS MAY BE SUBJECT TO ADDITIONAL
 COMMENTS.
  
 *PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1)
 RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED
 COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE
 APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE
 WILL BE 20% ($200) OF THE ORIGINAL APPLICATION FEE.
  
  
 GENERAL COMMENTS:
  
 1.) EVIDENCE (I.E. WRITTEN STATEMENT) THAT THE PROPOSED
 INGRESS/EGRESS ON 45TH STREET HAS BEEN REVIEWED BY THE
 COUNTY AND THERE ARE NO ISSUES WITH THE DESIGN AND THE
 LOCATION OF THE PROPOSED ACCESS POINT.
  
 2.) EVIDENCE (I.E. WRITTEN STATEMENT) THAT THE PROPOSED
 INGRESS/EGRESS ON MILITARY TRAIL HAS BEEN REVIEWED BY
 FDOT AND THERE ARE NO ISSUES WITH THE DESIGN AND THE
 LOCATION OF THE ACCESS POINT.
  
  
 SITE PLAN:
  
 1.) THE HANDICAP PARKING STALL DETAIL IN SHEET C1.A
 DOES NOT COMPLY WITH CITY STANDARDS. PLEASE ADDRESS.
 (SEE ATTACHED DETAIL)
  
 2.) PROVIDE A DETAIL OF THE BICYCLE RACK IN SHEET C1.A.
  
 3.) THERE ARE TWO (2) DUMPSTER DETAILS IN SHEET C1.A.
 DETAIL 8 DOES NOT COMPLY WITH THE STANDARDS PROVIDED IN
 ZLDR S.94-444, FIGURE XIV-3. PLEASE ADDRESS IN SHEETS
 C1.0 (KEYNOTES) AND SHEET C1.A.
  
 4.) PLEASE ADDRESS THE WALL MOUNTED LIGHT FIXTURES IN
 SHEET C1.0. DO THE FIXTURES PROJECT 3 FT. FROM THE WALL
 (AS MEASURED IN THE SITE PLAN)? A NOTATION IN THE
 KEYNOTES WOULD BE REQUIRED.
  
 5.) WILL THE PARKING SPACES ADJACENT TO THE BUILDING
 HAVE WHEEL STOPS OR WILL THE PEDESTRIAN WALKWAY BE
 CURBED TO PREVENT VEHICULAR ACCESS? PLEASE CLARIFY AND
 ILLUSTRATE.
  
 6.) IDENTIFY THE CORRECT LOCATION OF THE PROJECT IN THE
 VICINITY MAP IN SHEET C1.0
  
 7.) PLEASE CORRECT THE FOLLOWING IN THE SITE DATA
 TABULAR: BUILDING HEIGHT PROVIDED = 23?, LOADING SPACE:
 MINIMUM AND PROVIDED = 10? X 25?.
  
  
 LANDSCAPE PLAN:
  
 1.) THE TRANSFORMER, LOCATED ON THE NORTH SIDE OF THE
 PROPERTY, SHALL BE SCREENED IN ACCORDANCE WITH ZLDR
 S.94-444(B)). PLEASE ADDRESS AND PROVIDE A DETAIL.
  
 2.) THE VISIBILITY TRIANGLES IN SHEET L1.0 ARE NOT IN
 COMPLIANCE WITH ZLDR S.94-305(E). (SEE ATTACHED DETAIL)
  
  
 PHOTOMETRIC PLAN:
  
 1.) THE LIGHTING NOTES (SHEET P1.0) REFERENCES THE CITY
 OF NORTH LAUDERDALE?S LIGHTING STANDARDS. PLEASE
 CORRECT. (REPEAT COMMENT)
  
  
 SIGNAGE PLAN:
  
 1.) THE SIGN AREA SHALL BE CALCULATED AS THE AREA WITH
 THE SMALLEST RECTANGLE THAT ENCOMPASSES ALL ELEMENTS OF
 THE SIGN. (ZLDR S.94-405)
  
 2.) THE SCALE SEEMS TO BE INCORRECT. PLEASE ADDRESS.
  