Plan Review Notes
Plan Review Notes For Project Z13120013
Project Number Z13120013
Review Stop STORM
Sequence Number 2
Notes
Date Text
2014-06-02 20:59:25SITE PLAN APPROVED WITH THE FOLLOWING CONDITIONS:
 1. VERTICAL DATUM ON SITE PLAN SHEET C1.0 INDICATED AS
 NAVD 1988. PER CITY CODE, VERTICAL DATUM IS TO
 REFERENCE NGVD 1929.
 2. COMPLETE THE FINISHED FLOOR ELEVATION STATEMENT ON
 SHEET C1.0.
 3. INDICATE VERTICAL DATUM ON GRADING AND DRAINAGE PLAN
 SHEET C1.1.
 4. RECOMMEND 15" DIAMETER AS MINIMUM MAINLINE STORM
 PIPE SIZE.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 561-494-1120
  
  