Plan Review Notes
Plan Review Notes For Project Z13120013
Project Number Z13120013
Review Stop STORM
Sequence Number 1
Notes
Date Text
2014-01-03 17:11:391. DRAINAGE DESIGN TO MEET SFWMD CRITERIA.
 2. PROVIDE COPY OF FDOT PERMIT BEFORE START OF
 CONSTRUCTION.
 3. PROVIDE COPY OF PALM BEACH COUNTY RIGHT-OF-WAY
 PERMIT BEFORE START OF CONSTRUCTION.
 4. PROVIDE SIGNED AND SEALED SWPPP AND FINAL PGD PLANS
 WITH ENGINEERING PERMIT APPLICATION.
 5. PROVIDE SIGNED AND SEALED DRAINAGE CALCULATIONS WITH
 ENGINEERING PERMIT APPLICATION.
 6. VERTICAL DATUM ON SURVEY AND ENGINEERING PLANS NEEDS
 TO BE NGVD 1929.
 7. INDICATE CONTROL STRUCTURE LOCATION FOR DRAINAGE
 SYSTEM.
 8. SHOW LOCATIONS OF DOWN SPOUTS CONNECTING INTO
 DRAINAGE SYSTEM. DOWN SPOUTS SHOULD CONNECT DIRECTLY
 INTO CATCH BASINS OR DRAINAGE MANHOLES WHERE EVER
 POSSIBLE.
 9. SHOW ALL PROPOSED AND EXISTING UTILITIES ON
 LANDSCAPE PLANS. DRAINAGE IS NOT SHOWN.
 10. VERIFY OWNERSHIP OF EXISTING SANITARY SEWER SYSTEM
 THAT IS BEING CONNECTED TO. WILL EASEMENT BE NEEDED FOR
 LATERAL CONNECTION OUTSIDE THE APPLICANT'S PROPERTY?
 11. AVOID PLANTING TREES WITHIN 5 FEET OF UNDERGROUND
 UTILITIES.
  