Plan Review Notes
Plan Review Notes For Project Z13090012
Project Number Z13090012
Review Stop STORM
Sequence Number 1
Notes
Date Text
2013-09-30 14:35:461. PROVIDE DRAINAGE SYSTEM FOR NORTHWEST PARKING AREA
 ON GROUND FLOOR.
 2. INCLUDE BAFFLE SYSTEM TO PREVENT OILS/FLOATABLES
 FROM ENTERING EXFILTRATION SYSTEM AND DISCHARGING
 OFFSITE TO CITY'S MS4.
 3. PRELIMINARY ENGINEERING PLAN (C-1) DOES NOT MATCH
 SITE PLAN (SP-1) - LANDSCAPE ISLAND ON FERN STREET
 WHERE THE WATER MAIN CROSSES THE LANDSCAPE ISLAND.
 4. INDICATE VERTICAL DATUM ON PRELIMINARY ENGINEERING
 PLAN (SHOULD BE NGVD 1929).
 5. AVOID LOCATING UTILITIES UNDER LANDSCAPING/TREE
 PLANTERS.
 6. RELOCATE PROPOSED CATCH BASIN AND EXISTING CATCH
 BASIN IN FERN STREET RIGHT-OF-WAY TO CURB LINE UNLESS
 THE ON-STREET PARKING AREA TO BE REGRADED TO DRAIN TO
 EDGE OF TRAVEL LANE.
 7. WITH ENGINEERING PERMIT APPLICATION PROVIDE:
 A. WATER QUALITY TREATMENT CALCULATIONS PER SFWMD
 CRITERIA
 B. LAND USE AREAS
 C. ENGINEERING PLANS (PAVING, GRADING, DRAINAGE, WATER,
 SEWER)
 C. SWPPP PLAN
 8. BEFORE START OF CONSTRUCTION PROVIDE:
 A. SFWMD ERP PERMIT OR PERMIT MODIFICATION.
 B. FDEP NPDES PERMIT FOR CONSTRUCTION STORMWATER
 RUNOFF.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 (561) 494-1120
  