Plan Review Notes
Plan Review Notes For Project Z13090012
Project Number Z13090012
Review Stop POLICE
Sequence Number 1
Notes
Date Text
2013-11-13 07:55:30COMMENTS FROM POLICE
 1.ACCESS CONTROL TO ENTER ELEVATOR LOBBIES ON THE FIRST
 FLOOR, CLUBROOM ENTRY FROM THE VALET AREA, DOOR LEADING
 INTO THE SERVICE CORRIDOR/SERVICE AREA, ALL OFFICE
 DOORS, AND ROOF ENTRANCE
 2. CCTV AT ALL LOBBIES ON EACH FLOOR (INCLUDING PARKING
 GARAGE), SERVICE CORRIDOR, SERVICE LOADING AREA, VALET,
 LOBBY ENTRY DOORS, GARAGE ENTRY/EXITS, STAIRWELL
 ENTRY/EXITS ON FIRST FLOOR OF RESIDENTIAL, STAIRWELL
 LOBBIES ON EACH LEVEL OF THE PARKING GARAGE, ROOF
 ACCESS LOBBY, POOL/RECREATIONAL AREAS.
 3. WHO HAS ACCESS TO THE PRIVATE BALCONIES?
 CPTED STANDARDS
 DESIGN
 A. PARKING GARAGE FIRST LEVEL SHALL HAVE RESTRICTED
 ACCESS FROM EXTERIOR COMMON GROUND AREA.
 B. METAL SCREENING SHALL BE IN PLACE BETWEEN THE TOP OF
 THE WALL (CRASH BARRIER) AND THE FLOORING OF THE SECOND
 PARKING LEVEL.
 C. CRASH BARRIERS AROUND THE PERIMETER OF THE PARKING
 GARAGE AND THE SHEAR WALLS THROUGHOUT THE INTERIOR
 COULD BE ?-INCH STEEL CABLES OR WROUGHT IRON FENCING
 INSTEAD OF SOLID WALLS, ALLOWING FOR MORE NATURAL LIGHT
 AND AN UNOBSTRUCTED LINE OF SIGHT.
 D. GROUND LEVEL PEDESTRIAN EXITS THAT OPEN INTO
 NON-SECURE AREAS SHALL BE EMERGENCY EXITS ONLY AND
 FITTED WITH PANIC BAR HARDWARE.
 E. CENTER OF THE GARAGE SHALL HAVE CONNECTIVITY TO ALL
 CROSSWALKS.
 F. DIRECTIONAL ARROWS AND SIGNAGE INDICATING EXITS,
 STAIRS, AND ELEVATORS SHALL BE PROVIDED.
 G. PEDESTRIAN ENTRANCES SHALL BE ADJACENT TO VEHICLE
 ENTRANCES, OPEN AND FREE OF HIDDEN SPACES AND WIRED FOR
 CCTV SURVEILLANCE.
 H. PUBLIC AND PRIVATE PARKING SPACES SHALL BE
 DESIGNATED.
 I. WALLS AND SUPPORT STRUCTURES SHALL ALL BE
 CONSTRUCTED WITH OPEN SIDES TO AVOID CREATION OF HIDDEN
 SPACES.
 J. ACCESS POINTS TO THE FACILITY SHALL BE MINIMIZED.
 K. CEILINGS AND SOLID WALLS IN THE PARKING GARAGE SHALL
 BE PAINTED WHITE TO INCREASE BRIGHTNESS WITHIN THE
 FACILITY.
 L. CONVEX MIRRORS SHALL BE INSTALLED IN STAIRWELL AND
 ELEVATOR AREAS.
 M. UTILIZE SECURITY VISION DOORS AT ENTRANCE TO
 STAIRWELLS ON EACH FLOOR.
 N. EACH LEVEL OF THE PARKING GARAGE SHALL BE EQUIPPED
 WITH WELL-MARKED EMERGENCY TELEPHONE.
 ELEVATORS
 A. ELEVATORS SHALL BE EQUIPPED WITH EMERGENCY TWO-WAY
 COMMUNICATION.
 B. ELEVATORS SHALL HAVE NO STOP BUTTON.
 C. ELEVATORS SHALL BE LOCATED CLOSE TO THE MAIN
 ENTRANCE, CONSTRUCTED TO AVOID HIDDEN SPACES AND
 UTILIZE CCTV SURVEILLANCE.
 STAIRWELLS
 A. STAIRWELLS SHOULD BE WELL LIT AND HAVE CONVEX
 MIRRORS AT EACH LANDING.
 LIGHTING
 A. THE EXTERIOR OF THE PARKING GARAGE SHALL BE WELL LIT
 ON ALL SIDES.
 B. CEILINGS AND SOLID WALLS IN THE PARKING GARAGE SHALL
 BE LIGHT IN COLOR TO INCREASE REFLECTIVENESS OF THE
 LIGHTING LUMINARIES.
 C. ALL LIGHTING SHALL BE VANDALISM RESISTANT.
 D. LIGHTING SHOULD BE PLACED WHERE USERS REQUIRE
 LIGHTS: OVER VEHICLES, STAIRWELLS,
 CCTV CAMERAS.
 E. LIGHTING FIXTURES SHOULD BE EXTENDED PAST THE BEAMS
 IN THE GARAGE CEILING
 F. ALL LIGHTING SHALL ADHERE TO ILLUMINATING
 ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) STANDARDS
 FOR PARKING GARAGES UTILIZING LED LIGHTING. IF
 NECESSARY, PLEASE CONTACT THEM AT (212) 248-500 FOR
 FURTHER INFORMATION. ENHANCED LIGHTING SHALL BE USED AT
 ENTRANCE/EXITS TO REDUCE TRANSITION (FROM DAYLIGHT)
 WHEN ENTERING STRUCTURE.
 COMMERCIAL SECURITY
 DOORS
 A. EXTERIOR DOORS SHALL ALL BE EQUIPPED WITH SECURITY
 HINGES AND SHALL BE REINFORCED WITH CASE HARDENED
 STRIKE PLATES. CASE HARDENED DEADBOLT LOCKS SHALL BE
 PROVIDED ON ALL EXTERIOR DOORS WITH A MINIMUM (1) INCH
 THROW OR MECHANICAL INTERLOCK.
 B. GLASS PERIMETER DOORS SHALL BE EQUIPPED WITH CASE
 HARDENED GUARD RINGS TO PROTECT THE MORTISE LOCK
 CYLINDER.
 C. REAR DOORS SHALL BE EQUIPPED WITH 180-DEGREE
 PEEPHOLE/ SECURITY VIEWER.
 D. SIGNS SHALL CLEARLY IDENTIFY PUBLIC ENTRANCES
  
 CONDO SECURITY
 DOORS
 A. DOOR LEADING INTO A RESIDENTIAL UNIT SHALL BE SOLID
 CORE.
 B. EXTERIOR DOORS SHALL BE EQUIPPED WITH A 180-DEGREE
 PEEPHOLE AND NON-REMOVABLE SECURITY HINGES.
 LOCKS
 A. ANTI-LIFTING AUXILIARY LOCKS SHALL BE INSTALLED ON
 SLIDING DOORS AND WINDOWS.
 B. ALL DOORS SHALL BE EQUIPPED WITH SINGLE CYLINDER
 DEAD BOLT LOCK WITH A MINIMUM THROW OF ONE INCH AND AN
 EMBEDMENT OF NOT LESS 5/8 INCH INTO THE HOLDING DEVICE.
 PICK PLATES SHOULD ALSO BE PLACED ALL EXTERIOR DOORS.
  
  
  
 CONSTRUCTION SITE
  
 CONDITIONS FOR APPROVAL
 PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE
 APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY
 AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST
 PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL.
 A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION
 TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE
 SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES
 FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT
 BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL,
 VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS,
 REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE
 SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF
 WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER
 MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE
 WORKING ENVIRONMENT.
 B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED
 THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT.
 NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A
 STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT
 DEVELOPMENT.
 C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY
 500 FEET AROUND THE PERIMETER OF THE SITE.
  
  
  
  
  Print


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved