| Date |
Text |
| 2013-09-09 13:17:49 | NEED TO SEE A SECURITY PLAN SHOWING LOCATIONS OF |
| | CAMERAS AND CAMERAS WITH LIGHTING. |
| | NEED TO SEE LIGHTING PLANS FOR THE GARAGE |
| | |
| | |
| | |
| | CONDITIONS FOR APPROVAL |
| | PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE |
| | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY |
| | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST |
| | PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. |
| | A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION |
| | TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE |
| | SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES |
| | FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT |
| | BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, |
| | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, |
| | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE |
| | SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF |
| | WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER |
| | MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE |
| | WORKING ENVIRONMENT. |
| | B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED |
| | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. |
| | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A |
| | STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT |
| | DEVELOPMENT. |
| | C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY |
| | 500 FEET AROUND THE PERIMETER OF THE SITE. |
| | |
| | 1.1 LIGHTING FOR HOTEL AREAS |
| | A. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS, |
| | BUILDING ADDRESS NUMBERS, LIGHTING AND WALKWAYS. |
| | B. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR |
| | ABOVE OR NEAR ENTRYWAYS AND ALL PEDESTRIAN SIDEWALKS |
| | SHALL BE PROVIDED. |
| | C. LIGHTING FOR ENTRANCE SIGN SHALL BE PROVIDED. |
| | D. LIGHTING ON BUILDINGS SHALL BE AROUND PERIMETER OF |
| | ALL SIDES AND ON PEDESTRIAN WALKWAY SURROUNDING THE |
| | BUILDINGS. |
| | 1.2 NUMERICAL ADDRESS |
| | A. ILLUMINATED FOR NIGHTTIME VISIBILITY IS REQUIRED. |
| | B. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS |
| | REQUIRED. |
| | C. ADDRESS NUMBERS ON DOORS NEED TO BE A MINIMUM OF 6 |
| | INCHES HIGH. |
| | 1.3 GUESTROOMS |
| | A. GUESTROOMS ALL NEED TO HAVE ELECTRONIC CARD. |
| | B. DOORS SHALL BE SOLID-CORE WOOD OR METAL, AND BE |
| | SELF-CLOSING AND SELF-LOCKING. THE DOOR LOCK MUST |
| | CONSIST OF A HIGH QUALITY DEADBOLT WITH AT LEAST A |
| | ONE-INCH BOLT. THE LOCK STRIKE-PLATE MUST BE BOLTED |
| | SECURELY TO THE METAL DOORFRAME OR BY USING THREE-INCH |
| | SCREWS WHEN ATTACHED TO A WOOD DOORJAMB. ACCESSIBLE |
| | SLIDING WINDOWS MUST HAVE SECONDARY SECURITY DEVICES |
| | ATTACHED TO PREVENT FORCED ENTRY OR LIFTING OUT OF THE |
| | FRAME. |
| | C. EACH GUESTROOM SHALL BE PROVIDED WITH IN-ROOM |
| | ELECTRONIC SAFES. (NOTE: MUST BE PREPLANNED BY |
| | ELECTRICAL ENGINEER FOR ELECTRICAL HOOK-UP.) |
| | D. GUESTROOMS SHALL NOT BE ACCESSIBLE FROM OUTSIDE |
| | UNLESS BY ELECTRONIC ACCESS. |
| | 1.4 EXTERIOR |
| | A. EXTERIOR BUILDING LIGHTING SHALL BE REQUIRED FOR ALL |
| | EXIT WAY, EMERGENCY ACCESS, STAIRWAY AND UTILITY ROOM |
| | DOORS. |
| | B. SECONDARY ACCESS, OTHER THAN MAIN LOBBY, SHALL BE |
| | AVAILABLE BY CONTROLLED ACCESS. |
| | C. POOL AREA RESTRICTED ACCESS HELPS PREVENT |
| | UNAUTHORIZED USE, CURBS POTENTIAL VANDALISM AND |
| | PROVIDES GREATER SECURITY AND PROTECTION TO POOL USERS, |
| | ESPECIALLY CHILDREN. |
| | D. ALL EXITING DOORS NEED VIEW WINDOW OR PEEPHOLE. |
| | 1.5 MISCELLANEOUS |
| | |
| | A. PAY PHONES SHALL BE KEPT IN OPEN AREAS, PREFERABLY |
| | WITHIN VIEW OF THE FRONT DESK. |
| | B. LEGENDS, MARQUIS MAPS, ETC., SHALL BE USED |
| | INDICATING LOCATIONS OF CONFERENCE ROOMS, ELEVATORS, |
| | STAIRS, LOBBY AREAS, RESTAURANTS, POOL, TENNIS COURT, |
| | WORKOUT ROOM, ETC. |
| | C. GIFT SHOP WINDOWS SHALL BE CLEAR TO INCREASE NATURAL |
| | SURVEILLANCE |
| | D. ATM INSTALLATION SHALL MEET FSS REQUIREMENTS |
| | E. STAIRWELLS SHALL HAVE CONVEX MIRRORS INSTALLED AT |
| | LANDINGS FOR EACH LEVEL. |
| | F. INTERIOR OF ELEVATORS SHALL UTILIZE MIRRORS AND CCTV |
| | G. INSTALL CCTV FOR SURVEILLANCE OF LOBBY, STAIRWELLS, |
| | PARKING LOTS, POOL, FITNESS ROOM, POOL RESTROOM |
| | CORRIDOR, LOADING DOCKS, VALET STAND, LOBBY, CHECK IN |
| | COUNTER, ESCALATOR LOBBIES AND SERVICE AREAS OF BANQUET |
| | ROOMS. |
| | H. ACCESS CONTROL TO ALL EMPLOYEE AREAS. |
| | |
| | 1.6 PARKING GARAGE DESIGN |
| | A. PARKING GARAGE FIRST LEVEL SHALL HAVE RESTRICTED |
| | ACCESS FROM EXTERIOR COMMON GROUND AREA. |
| | B. EXTERIOR WALLS SURROUNDING THE FIRST FLOOR (GROUND |
| | LEVEL) PARKING SHALL BE AT LEAST 3 TO 4 FEET HIGH. |
| | C. METAL SCREENING SHALL BE IN PLACE BETWEEN THE TOP OF |
| | THE WALL (CRASH BARRIER) AND THE FLOORING OF THE SECOND |
| | PARKING LEVEL. |
| | D. OPEN MESH-TYPE SCREENING PROVIDES MAXIMUM VISIBILITY |
| | FROM THE EXTERIOR WHILE ELIMINATING THE OPPORTUNITY OF |
| | ACCESS BY SOMEONE CLIMBING OVER THE WALL. |
| | E. CRASH BARRIERS AROUND THE PERIMETER OF THE PARKING |
| | GARAGE AND THE SHEAR WALLS THROUGHOUT THE INTERIOR |
| | COULD BE ?-INCH STEEL CABLES OR WROUGHT IRON FENCING |
| | INSTEAD OF SOLID WALLS, ALLOWING FOR MORE NATURAL LIGHT |
| | AND AN UNOBSTRUCTED LINE OF SIGHT. |
| | F. GROUND LEVEL PEDESTRIAN EXITS THAT OPEN INTO |
| | NON-SECURE AREAS SHALL BE EMERGENCY EXITS ONLY AND |
| | FITTED WITH PANIC BAR HARDWARE. |
| | G. CENTER OF THE GARAGE SHALL HAVE CONNECTIVITY TO ALL |
| | CROSSWALKS. |
| | H. DIRECTIONAL ARROWS AND SIGNAGE INDICATING EXITS, |
| | STAIRS, AND ELEVATORS SHALL BE PROVIDED. |
| | I. PEDESTRIAN ENTRANCES SHALL BE ADJACENT TO VEHICLE |
| | ENTRANCES, OPEN AND FREE OF HIDDEN SPACES AND WIRED FOR |
| | CCTV SURVEILLANCE. |
| | J. PUBLIC AND PRIVATE PARKING SPACES SHALL BE |
| | DESIGNATED. |
| | K. WALLS AND SUPPORT STRUCTURES SHALL ALL BE |
| | CONSTRUCTED WITH OPEN SIDES TO AVOID CREATION OF HIDDEN |
| | SPACES. |
| | L. ACCESS POINTS TO THE FACILITY SHALL BE MINIMIZED. |
| | M. CEILINGS AND SOLID WALLS IN THE PARKING GARAGE SHALL |
| | OF LIGHT IN COLOR CONCRETE OR BE PAINTED WHITE TO |
| | INCREASE BRIGHTNESS WITHIN THE FACILITY. |
| | N. CONVEX MIRRORS SHALL BE INSTALLED IN STAIRWELL AND |
| | ELEVATOR AREAS. |
| | O. UTILIZE SECURITY VISION DOORS AT ENTRANCE TO |
| | STAIRWELLS ON EACH FLOOR. |
| | 1.7 TELEPHONES |
| | A. EACH LEVEL OF THE PARKING GARAGE SHALL BE EQUIPPED |
| | WITH WELL-MARKED, DIRECT RING EMERGENCY TELEPHONES. |
| | B. TELEPHONES SHALL TERMINATE AT A CENTRAL STAFFED |
| | MONITORING OFFICE, STATION OR BOOTH. |
| | 1.8 ELEVATORS |
| | A. ELEVATORS SHALL BE EQUIPPED WITH EMERGENCY TWO-WAY |
| | COMMUNICATION. |
| | B. ELEVATORS SHALL HAVE NO STOP BUTTON. |
| | C. ELEVATORS SHALL BE LOCATED CLOSE TO THE MAIN |
| | ENTRANCE, CONSTRUCTED TO AVOID HIDDEN SPACES AND |
| | UTILIZE CCTV SURVEILLANCE. |
| | |
| | STAIRWELLS |
| | A. STAIRWELLS SHOULD BE WELL LIT OR HAVE AN OPEN |
| | DESIGN. |
| | 1.9 LIGHTING |
| | A. THE EXTERIOR OF THE PARKING GARAGE SHALL BE WELL LIT |
| | ON ALL SIDES. |
| | B. ALL LIGHTING SHALL BE VANDALISM RESISTANT. |
| | C. LIGHTING SHOULD BE PLACED WHERE USERS REQUIRE |
| | LIGHTS: OVER VEHICLES, |
| | STAIRWELLS, CCTVCAMERAS. |
| | D. LIGHTING FIXTURES SHOULD BE EXTENDED PAST THE BEAMS |
| | IN THE GARAGE |
| | CEILING |
| | E. ALL LIGHTING SHALL ADHERE TO ILLUMINATING |
| | ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) STANDARDS |
| | FOR PARKING GARAGES UTILIZING LED LIGHTING. IF |
| | NECESSARY, PLEASE CONTACT THEM AT (212) 248-500 FOR |
| | FURTHER INFORMATION. ENHANCED LIGHTING SHALL BE USED AT |
| | ENTRANCE/EXITS TO REDUCE TRANSITION (FROM DAYLIGHT) |
| | WHEN ENTERING STRUCTURE. |
| | 1.10 CAMERAS (IF INSTALLING CCTV) |
| | A. CCTV CAMERAS LOCATED ON EACH FLOOR OF THE PARKING |
| | GARAGE (AS WELL AS MONITORING ACCESS POINTS, ATTENDANT |
| | BOOTH, STAIRWELLS, LOBBY, ETC.). |
| | B. THE MONITORING AND CONTROL OF THE CCTV CAMERAS SHALL |
| | BE AT A CENTRAL MONITORING OFFICE OR BOOTH. |
| | C. A HIGH-RESOLUTION COLOR DIGITAL VIDEO CAMERA SYSTEM |
| | WITH MONITORING AND PHOTO PROCESSING PRINTOUT |
| | CAPABILITIES SHALL BE USED. |
| | 1.11 LANDSCAPING |
| | A. VEGETATION, PLANT GROWTH AND LANDSCAPING AROUND THE |
| | PERIMETER OF THE PARKING GARAGE SHALL BE MINIMIZED AT |
| | HEIGHT OF NO MORE THAN 3 FEET AND TREE CANOPIES PRUNED |
| | ABOVE 8 FT FOR MATURE TREES. CLEAR ZONE FOR VISIBILITY |
| | BETWEEN 3 AND 8 FEET. |
| | |
| | |
| | |
| | |
| | |
| |
Print |