| 2013-08-13 20:22:58 | DEVELOPMENT SERVICES DEPARTMENT, BUILDING DIVISION, |
| | COMMENTS: |
| | |
| | 1. THIS REVIEW IS A CURSORY REVIEW AS IT RELATES TO THE |
| | SITE. IT IS NOT A REVIEW FOR FULL COMPLIANCE WITH |
| | FLORIDA BUILDING CODE. THE FOLLOWING COMMENTS ARE TO BE |
| | ADDRESSED FOR PERMITTING. |
| | |
| | 2. OF THE REQUIRED FIVE ACCESSIBLE PARKING SPACES, ONLY |
| | FOUR OF THEM ARE LOCATED CLOSE TO THE CLUBHOUSE. AT |
| | LEAST OF THE REMAINING TWO ACCESSIBLE PARKING SPACES |
| | SHALL BE LOCATED CLOSE TO THE CLUBHOUSE. PER SECTION |
| | 208.3 OF FLORIDA ACCESSIBILITY CODE ACCESSIBLE PARKING |
| | SPACES ARE TO BE LOCATED ON THE SHORTEST POSSIBLE ROUTE |
| | OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBLE |
| | ENTRANCE FOR EACH BUILDING. THE DESIGN OF ACCESSIBLE |
| | PARKING SPACES SHALL COMPLY WITH SECTION 502 OF FLORIDA |
| | ACCESSIBILITY CODE |
| | |
| | 3. THE ACCESSIBLE CONCRETE WALK PROVIDES ACCESS TO THE |
| | CLUBHOUSE, BUT IT DOES NOT PROVIDE ACCESS TO THE CART |
| | STORAGE AND LOADING AREA. WHEN SUBMITTED FOR PERMIT, |
| | THE PLANS SHALL SHOW AT LEAST ONE ACCESSIBLE ROUTE, |
| | COMPLYING WITH SECTIONS 206.2 AND 402.2 OF FLORIDA |
| | ACCESSIBILITY CODE, FROM THE PUBLIC RIGHT-OF-WAY TO ALL |
| | ACCESSIBLE BUILDING OR FACILITY ENTRANCES. |
| | |
| | 4. THE ACCESSIBLE CONCRETE WALK DOES NOT PROVIDE ACCESS |
| | TO THE CART STORAGE AND LOADING AREA. SHOW AT LEAST ONE |
| | ACCESSIBLE ROUTE, COMPLYING WITH SECTIONS 206.2 AND |
| | 402.2 OF FLORIDA ACCESSIBILITY CODE, CONNECTING |
| | ACCESSIBLE BUILDING OR FACILITY ENTRANCES WITH ALL |
| | ACCESSIBLE SPACES AND ELEMENTS WITHIN THE BUILDING OR |
| | FACILITY. |
| | |
| | 5. THE CONSTRUCTION TYPE FOR THE MANUFACTURED BUILDING |
| | TO BE USED FOR THE CLUBHOUSE IS NOT STATED. ALSO THE |
| | PLAN SHOWS A PROPOSED TENT LOCATED SO CLOSE TO THAT |
| | BUILDING THAT THE TWO WOULD HAVE TO BE CONSIDERED AS |
| | ONE STRUCTURE FOR THE PURPOSES OF CONSTRUCTION TYPE, |
| | AND BUILDING AREA. FOR PERMITTING, THE TYPE OF |
| | CONSTRUCTION FOR THE BUILDINGS SHALL BE IN ACCORDANCE |
| | WITH THE HEIGHT, AREA AND OCCUPANCY LIMITATIONS IN |
| | CHAPTER 5 OF THE FLORIDA BUILDING CODE. |
| | |
| | 6. THE PLANS SHOW ONE TENT LESS THAN 2 FEET FROM THE |
| | PROPERTY LINE AND ANOTHER TENT IMMEDIATELY ADJACENT TO |
| | THE CLUBHOUSE. THE LOCATION OF STRUCTURES SHALL COMPLY |
| | WITH ALL BUILDING SEPARATION, PERCENTAGE OF OPENINGS |
| | AND OPENING PROTECTIVE REQUIREMENTS OF CHAPTERS 6 AND 7 |
| | OF THE FLORIDA BUILDING CODE. |
| | |
| | 7. FOR THE TENTS, FULL DETAILS AND FLAME SPREAD |
| | CERTIFICATION SHALL BE SUBMITTED WITH THE PERMIT |
| | APPLICATION. |
| | |
| | 8. ALL APPLICABLE PERMITS MUST BE OBTAINED BEFORE |
| | COMMENCING THE WORK. |
| | |
| | ROBERT BROWN |
| | BUILDING OFFICIAL |
| | TEL: 561 805 6652 |