| 2013-10-01 00:07:17 | 1. PREVIOUS COMMENTS ACKNOWLEDGED BUT SOME WERE NOT |
| | ADDRESSED. ALL PREVIOUS COMMENTS STILL APPLY. |
| | 2. PROVIDE TOPOGRAPHIC SURVEY WITH ELEVATIONS |
| | REFERENCED TO NGVD 1929. SPOT GRADES SHALL BE PROVIDED |
| | AT PROPERTY LINE AND 5 FEET OUTSIDE PROPERTY LINE TO |
| | DETERMINE IF THERE IS OFF SITE RUNOFF ENTERING THE |
| | SITE. |
| | 3. BICYCLE RACK APPEARS TO BE SURROUNDED WITH GROUND |
| | COVER PLANTS. THE BIKE RACK WILL BE DIFFICULT TO ACCESS |
| | IF THERE IS A VEHICLE IN THE FIRST PARKING SPACE. IF |
| | ALLOWED BY PLANNING DEPT., CONSIDER MOVING TO THE |
| | NORTHEAST, TO ADJACENT TO THE CURB NEXT TO THE ADA |
| | ACCESSABLE ROUTE. |
| | 4. CREATE SWALE IN LANDSCAPE AREA ADJACENT TO WEST |
| | PROPERTY LINE IN ORDER TO RETAIN SOME STORMWATER |
| | RUNOFF. |
| | 5. CREATE SWALE IN REAR OF BUILDING TO PREVENT DIRECT |
| | RUNOFF TO ADJACENT LOT. |
| | 6. TIE ROOF DRAINS DIRECTLY INTO DRAINAGE SYSTEM OR |
| | DISCHARGE ONTO PERVIOUS AREA. |
| | 7. SHOW EXTENT OF SIDEWALK/CURB REMOVAL-REPLACEMENT ON |
| | OLD OKEECHOBEE ROAD FOR PROPOSED DRIVEWAY. |
| | 8. NARROW DRIVEWAY WIDTH IF NOT USED FOR TWO-WAY |
| | TRAFFIC. ADD STOP BAR AND STOP SIGN IF USED FOR TWO-WAY |
| | TRAFFIC. |
| | 9. TO PROTECT BUILDING FROM VEHICLES, CONSIDER ADDING |
| | BOLLARDS AT CORNER OF BUILDING NEXT TO ADA ACCESSABLE |
| | ROUTE. |
| | 10. THE ADA ENTRANCE GATE MAY NEED SIDEWALK AREA TO THE |
| | SIDE OF THE GATE ON THE INSIDE OF THE FENCE TO ALLOW |
| | SOMEONE IN A WHEELCHAIR TO OPEN THE GATE. |
| | 11. ADD LEGEND TO CONCEPTUAL ENGINEERING PLAN |
| | IDENTIFYING ALL OF THE SYMBOLS SHOWN ON THE PLAN. |
| | |
| | TRACY L. WARD, P.E. |
| | SENIOR STORMWATER ENGINEER |
| | ENGINEERING AND PUBLIC WORKS DEPARTMENT |
| | 561-494-1120 |
| |