| Date |
Text |
| 2013-07-03 10:32:45 | A. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS, |
| | BUILDING ADDRESS NUMBERS, LIGHTING AND WALKWAYS. IT |
| | SHALL BE MAINTAINED AT 3 FEET OR LESS. TREES SHALL BE |
| | INSTALLED SO AS NOT TO CONFLICT WITH THE LIGHTING |
| | SYSTEM. LOWER CANOPY LIMBS ON TREES SHALL BE MAINTAINED |
| | AT 8 FEET OR HIGHER |
| | B. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR |
| | ABOVE OR NEAR ENTRYWAYS TO BUILDINGS FOR DUSK TO DAWN |
| | OPERATION SHALL BE PROVIDED. |
| | C. BUILDING NUMBERS SHALL BE A MINIMUM OF 12 INCHES |
| | HIGH AND PLACED IN A CONSPICUOUS LOCATION AWAY FROM |
| | LANDSCAPING. MULTIPLE LOCATIONS MAY BE REQUIRED. |
| | NUMBERS OF CONTRASTING COLORS SHOULD BE USED. ADDRESS |
| | SHOULD BE PLACED UNDER A LIGHT FIXTURE OR BE BACK LIT. |
| | D. EXTERIOR DOORS SHALL ALL BE EQUIPPED WITH SECURITY |
| | HINGES AND SHALL BE REINFORCED WITH CASE HARDENED |
| | STRIKE PLATES. CASE HARDENED DEADBOLT LOCKS SHALL BE |
| | PROVIDED ON ALL EXTERIOR DOORS WITH A MINIMUM (1) INCH |
| | THROW OR MECHANICAL INTERLOCK. |
| | E. GLASS PERIMETER DOORS SHALL BE EQUIPPED WITH CASE |
| | HARDENED GUARD RINGS TO PROTECT THE MORTISE LOCK |
| | CYLINDER. |
| | F. REAR DOORS SHALL BE EQUIPPED WITH 180-DEGREE |
| | PEEPHOLE/ SECURITY VIEWER. |
| | G. ALL BUILDINGS SHALL BE PRE-WIRED FOR CLOSED-CIRCUIT |
| | TELEVISION (CCTV) AND ALARM SYSTEMS. |
| | |
| | PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE |
| | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY |
| | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST |
| | PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. |
| | A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION |
| | TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE |
| | SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES |
| | FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT |
| | BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, |
| | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, |
| | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE |
| | SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF |
| | WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER |
| | MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE |
| | WORKING ENVIRONMENT. |
| | B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED |
| | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. |
| | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A |
| | STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT |
| | DEVELOPMENT. |
| | PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY |
| | 500 FEET AROUND THE PERIMETER OF THE SITE |
| | |
| |
Print |