2013-06-06 19:05:181. CIVIL PLAN IS A COPY OF A SIGNED AND SEALED PLAN.
 2. CIVIL PLAN DOES NOT MATCH SITE PLAN. SITE PLAN SHOWS
 A SIDEWALK CONNECTION TO NORTH DIXIE HIGHWAY SIDEWALK.
 THIS SIDEWALK WILL AFFECT THE PROPOSED DRAINAGE SWALE.
 3. INDICATE VERTICAL DATUM ON CIVIL PLAN AND SITE
 PLAN.SURVEY INDICATES NGVD 1929.
 4. SIGNED AND SEALED DRAINAGE CALCULATIONS TO BE
 PROVIDED SHOWING WATER QUALITY TREATMENT IS BEING
 PROVIDED (PER SFWMD CRITERIA).
 5. ENTRANCE GATE WILL BLOCK THE FIRST REGULAR AND
 HANDICAP PARKING SPACES.
 6. CHECK PAVEMENT SLOPE OF EXISTING PARKING SO THAT NEW
 CURBING OF LANDSCAPE ISLANDS DOESN'T TRAP RUNOFF.
 7. SUGGEST THE 10' WIDE SIDEWALK BETWEEN HANDICAP
 PARKING SPACES BE 6" THICK IN CASE IT IS INADVERTENTLY
 USED FOR PARKING.
 8. SWPPP NEEDED WITH ENGINEERING PERMIT APPLICATION.
  