| Date |
Text |
| 2013-05-06 14:37:19 | CONDITIONS FOR APPROVAL |
| | PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE |
| | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY |
| | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST |
| | PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. |
| | A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION |
| | TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE |
| | SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES |
| | FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT |
| | BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, |
| | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, |
| | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE |
| | SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF |
| | WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER |
| | MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE |
| | WORKING ENVIRONMENT. |
| | B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED |
| | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. |
| | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A |
| | STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT |
| | DEVELOPMENT. |
| | C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY |
| | 500 FEET AROUND THE PERIMETER OF THE SITE. |
| | |
| | |
| | IN LOOKING AT THE PROPOSED PLANS: |
| | |
| | ROOF TOP ACCESS CONTROL WILL BE NEEDED |
| | LOADING AREA WILL NEED ACCESS CONTROL, LIGHTING AND |
| | CCTV |
| | BIKE STORAGE: IS IT ENCLOSED? ACCESS CONTROL? SHOULD BE |
| | CCTV |
| | PARKING GARAGE |
| | DESIGN |
| | A. PARKING GARAGE FIRST LEVEL SHALL HAVE RESTRICTED |
| | ACCESS FROM EXTERIOR COMMON GROUND AREA. |
| | B. GROUND LEVEL PEDESTRIAN EXITS THAT OPEN INTO |
| | NON-SECURE AREAS SHALL BE EMERGENCY EXITS ONLY AND |
| | FITTED WITH PANIC BAR HARDWARE. |
| | C. CENTER OF THE GARAGE SHALL HAVE CONNECTIVITY TO ALL |
| | CROSSWALKS. |
| | D. DIRECTIONAL ARROWS AND SIGNAGE INDICATING EXITS, |
| | STAIRS, AND ELEVATORS SHALL BE PROVIDED. |
| | E. PEDESTRIAN ENTRANCES SHALL BE ADJACENT TO VEHICLE |
| | ENTRANCES, OPEN AND FREE OF HIDDEN SPACES AND WIRED FOR |
| | CCTV SURVEILLANCE. |
| | F. PUBLIC AND PRIVATE PARKING SPACES SHALL BE |
| | DESIGNATED. |
| | G. WALLS AND SUPPORT STRUCTURES SHALL ALL BE |
| | CONSTRUCTED WITH OPEN SIDES TO AVOID CREATION OF HIDDEN |
| | SPACES. |
| | H. ACCESS POINTS TO THE FACILITY SHALL BE MINIMIZED. |
| | I. CEILINGS AND SOLID WALLS IN THE PARKING GARAGE SHALL |
| | BE OF REFLECTIVE MATERIAL TO INCREASE BRIGHTNESS WITHIN |
| | THE FACILITY. |
| | J. CONVEX MIRRORS SHALL BE INSTALLED IN STAIRWELL AND |
| | ELEVATOR AREAS. |
| | K. UTILIZE SECURITY VISION DOORS AT ENTRANCE TO |
| | STAIRWELLS ON EACH FLOOR. |
| | |
| | ELEVATORS |
| | A. ELEVATORS SHALL BE EQUIPPED WITH EMERGENCY TWO-WAY |
| | COMMUNICATION. |
| | B. ELEVATORS SHALL HAVE NO STOP BUTTON. |
| | C. ELEVATORS SHALL BE LOCATED CLOSE TO THE MAIN |
| | ENTRANCE, CONSTRUCTED TO AVOID HIDDEN SPACES AND |
| | UTILIZE CCTV SURVEILLANCE. |
| | STAIRWELLS |
| | A. STAIRWELLS SHOULD BE WELL LIT OR HAVE AN OPEN |
| | DESIGN. |
| | LIGHTING |
| | A. THE EXTERIOR OF THE PARKING GARAGE SHALL BE WELL LIT |
| | ON ALL SIDES. |
| | B. CEILINGS AND SOLID WALLS IN THE PARKING GARAGE SHALL |
| | BE OF REFLECTIVE MATERIAL TO INCREASE REFLECTIVENESS OF |
| | THE LIGHTING LUMINARIES. |
| | C. ALL LIGHTING SHALL BE VANDALISM RESISTANT. |
| | D. LIGHTING SHOULD BE PLACED WHERE USERS REQUIRE |
| | LIGHTS: OVER VEHICLES, STAIRWELLS, |
| | CCTV CAMERAS. |
| | E. LIGHTING FIXTURES SHOULD BE EXTENDED PAST THE BEAMS |
| | IN THE GARAGE CEILING |
| | F. ALL LIGHTING SHALL ADHERE TO ILLUMINATING |
| | ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) STANDARDS |
| | FOR PARKING GARAGES UTILIZING LED LIGHTING. IF |
| | NECESSARY, PLEASE CONTACT THEM AT (212) 248-5000 FOR |
| | FURTHER INFORMATION. ENHANCED LIGHTING SHALL BE USED AT |
| | ENTRANCE/EXITS TO REDUCE TRANSITION (FROM DAYLIGHT) |
| | WHEN ENTERING STRUCTURE. |
| | |
| | CAMERAS |
| | A. CCTV CAMERAS LOCATED ON EACH FLOOR OF THE PARKING |
| | GARAGE (AS WELL AS MONITORING ACCESS POINTS, ATTENDANT |
| | BOOTH, STAIRWELLS, LOBBY, ETC.). |
| | B. THE MONITORING AND CONTROL OF THE CCTV CAMERAS SHALL |
| | BE AT A CENTRAL MONITORING OFFICE OR BOOTH. |
| | C. A HIGH-RESOLUTION COLOR DIGITAL VIDEO CAMERA SYSTEM |
| | WITH MONITORING AND PHOTO PROCESSING PRINTOUT |
| | CAPABILITIES SHALL BE USED. |
| | LANDSCAPING |
| | A. VEGETATION, PLANT GROWTH AND LANDSCAPING AROUND THE |
| | PERIMETER OF THE PARKING GARAGE SHALL BE MINIMIZED AT |
| | HEIGHT OF NO MORE THAN 3 FEET AND TREE CANOPIES PRUNED |
| | ABOVE 8 FT FOR MATURE TREES. CLEAR ZONE FOR VISIBILITY |
| | BETWEEN 3 AND 8 FEET. |
| | |
| | APARTMENT SECURITY |
| | |
| | DOORS |
| | A. DOOR LEADING INTO A RESIDENTIAL UNIT, SHALL BE SOLID |
| | CORE. |
| | B. EXTERIOR DOORS SHALL BE EQUIPPED WITH A 180-DEGREE |
| | PEEPHOLE AND NON-REMOVABLE SECURITY HINGES. |
| | LOCKS |
| | A. ALL DOORS SHALL BE EQUIPPED WITH SINGLE CYLINDER |
| | DEAD BOLT LOCK WITH A MINIMUM THROW OF ONE INCH AND AN |
| | EMBEDMENT OF NOT LESS 5/8 INCH INTO THE HOLDING DEVICE. |
| | PICK PLATES SHOULD ALSO BE PLACED ALL EXTERIOR DOORS. |
| | MISCELLANEOUS |
| | A. STAIRWAYS (TO INCLUDE RISERS/BANISTERS) AND |
| | BALCONIES SHALL PROVIDE OPEN VIEWS. |
| | B. SALES CENTER, CLUBHOUSE AND RECREATIONAL FACILITIES |
| | SHALL BE PRE-WIRED TO ALARM CENTER. |
| | C. RECREATION BUILDING AND POOL ACCESS SHALL BE |
| | RESTRICTED, BY KEY, KEY FOB, OR CARD ACCESS |
| | D. BICYCLE SPACES SHALL BE LOCATED IN CLOSE PROXIMITY |
| | TO THE FRONT OF BUILDINGS AND NOT IN PARKING LOTS. |
| | E. MAILBOX LOCATIONS SHALL BE IN A WELL LIT, HIGH |
| | TRAFFIC LOCATION. |
| | |
| | |
| | |
| | |
| | |
| |
Print |