2013-08-15 20:33:08COMMENTS ON ENGINEERING PLANS PROVIDED BY DANIELLE ON
 8/5/13:
 1. THE UTILITIES SHOWN ON THE LANDSCAPE PLANS (S&S
 6/18/13) DO NOT MATCH THE UTILITIES SHOWN ON THE
 ENGINEERING PLAN (S&S 8/1/13) FOR EXAMPLE, THE
 LANDSCAPE PLAN DOES NOT SHOW THE DRAINAGE PIPE GOING
 ACROS THE EAST DRIVEWAY ENTRANCE.
 2. IT APPEARS THE SCALE BAR ON ENGINEERING PLAN SHOULD
 INDICATE 1" = 30 FEET, NOT 1" = 20 FEET.
 3. ALL PLANS (SITE PLAN, ENGINEERING PLAN, LANDSCAPE,
 ETC.) SHOULD BE SHOWN AT THE SAME SCALE.
 4. ELEVATIONS NEED TO BE SHOWN IN REFERENCE TO NGVD
 1929 VERTICAL DATUM. PUTTING THE CONVERSION BETWEEN
 NGVD AND NAVD 1988 AS A NOTE ON THE PLANS IS NOT
 SUFFICIENT.
 5. RELOCATE THE EXISTING SANITARY PIPE FROM UNDER THE
 PROPOSED DETENTION POND.
 6. WHERE DOES THE DRAINAGE SYSTEM OUTFALL TO? IS THERE
 A PROPOSED CONTROL STRUCTURE? THERE IS NOT AN EXISTING
 DRAINAGE SYSTEM SHOWN ALONG THE EAST PROPERTY LINE.
 7. PROVIDE DESIGN DATA, IF AVAILABLE, FOR THE DETENTION
 AREA, GRADING PLAN, AND DRAINAGE SYSTEM.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPT.
 (561) 494-1120
  
2013-07-24 08:10:34NO ENGINEERING PLANS OR CALCULATIONS IN THE JUNE 19,
 2013 SUBMITTAL.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 (561) 494-1120