Date Text
2013-06-28 13:10:37GENERALLY, THE STUDY FALLS SHORT IN WHAT WOULD BE
 EXPECTED FROM A TYPICAL TRAFFIC IMPACT STUDY.
  
 THE STUDY AS SUBMITTED IS UNACCEPTABLE FOR THE
 FOLLOWING REASONS:
  
 THE STUDY DOES NOT PRESENT A SEQUENTIAL ANALYSIS FROM
 EXISTING TRAFFIC TO FUTURE TRAFFIC WITH POTENTIAL
 DIVERSIONS
 THERE ARE NO GRAPHICS SHOWING SITE TRAFFIC AND DIVERTED
 TRAFFIC
 TRAFFIC COUNTS WERE TAKEN IN MAY AND NO SEASONAL
 ADJUSTMENT WAS APPLIED
 FIGURE 2 APPEARS TO BE MISSING
 SIGNALIZED INTERSECTION ANALYSIS WAS PERFORMED FOR
 UNSIGNALIZED INTERSECTIONS
  
 IT IS SUGGESTED THAT THE APPLICANT COME IN AND MEET
 WITH US SO WE CAN DISCUSS THE COMPONENTS OF AN
 ACCEPTABLE STUDY