Plan Review Notes
Plan Review Notes For Project Z13040019
Project Number Z13040019
Review Stop STORM
Sequence Number 1
Notes
Date Text
2013-05-08 16:07:151. PROVIDE COPY OF SFWMD ERP OR NO-NOTICE PERMIT PRIOR
 TO START OF CONSTRUCTION.
 2. PROVIDE COPY OF NPDES NOI PERMIT PRIOR TO START OF
 CONSTRUCTION.
 3. PROVIDE DRAINAGE CALCULATIONS, INCLUDING LAND USE
 BREAKDOWN (PERVIOUS, IMPERVIOUS, BUILDING, ETC), WATER
 QUALITY TREATMENT, ETC., WITH THE CITY'S ENGINEERING
 PERMIT APPLICATION.
 4. PROVIDE SWPPP PLAN WITH THE CITY'S ENGINEERING
 PERMIT APPLICATION.
 5. INDICATE VERTICAL DATUM ON THE PLANS (SHOULD BE NGVD
 1929).
 6. INDEPENDENT DRAINAGE SYSTEMS, EACH DESIGNED TO
 PROVIDE WATER QUALITY TREATMENT FOR THE DRAINAGE AREA
 TRIBUTARY TO THE SYSTEM AND EACH TO HAVE A CONTROL
 STRUCTURE, NORTH AND SOUTH OF EUCALYPTUS ST.
 7. DRAINAGE SYSTEM ON LOT SOUTH OF EUCALYPTUS ST.
 INTERCONNECTS DRAINAGE SYSTEMS ON EUCALYPTUS ST. AND
 6TH ST.
 8. FDOT PERMITS REQUIRED FOR DRAINAGE IMPACTS TO DIXIE
 HIGHWAY DRAINAGE SYSTEM AND SURFACE CHANGES TO THE 7TH
 ST/DIXIE HWY INTERSECTION. PROVIDE WITH THE CITY?S
 ENGINEERING PERMIT APPLICATION.
 9. HOW WILL BOTTOM LEVELS OF PARKING GARAGES DRAIN?
 10. SHOW WHERE THE EXISTING CATCH BASINS AT 7TH STREET
 / OLIVE AVE DRAIN TO.
  
 TRACY L. WARD, P.E.
 SENIOR STORMWATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT
 (561) 494-1120
  