| 2013-04-30 15:00:23 | CASE NO. PB950JJJJ |
| | LA FITNESS EAST ENTRANCE @ CITYPLACE |
| | 700 SOUTH ROSEMARY AVE |
| | |
| | - CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | |
| | - PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN |
| | WRITTEN FORMAT. |
| | |
| | - WHEN RESUBMITTING, PLEASE PROVIDE A MINIMUM OF FOUR |
| | (4) PAPER COPIES AND AN ELECTRONIC COPY IN .PNG/.PDF |
| | FORMAT OF ALL PLANS. PLEASE NOTE THAT CHANGES ON THE |
| | RESUBMITTED PLANS MAY RESULT IN ADDITIONAL COMMENTS. |
| | |
| | - PLEASE NOTE THAT IF THE PLANNING DIVISION HAS NOT |
| | RECEIVED A RESPONSE TO THE COMMENTS WITHIN 60 DAYS FROM |
| | THE DATE OF THESE COMMENTS (JUNE 30, 2013), THE CASE |
| | SHALL BE CONSIDERED WITHDRAWN. ANY FURTHER ACTION SHALL |
| | REQUIRE A NEW DEVELOPMENT APPLICATION. |
| | |
| | - PLEASE NOTE THAT YOU WILL BE PERMITTED ONE (1) |
| | RESUBMITTAL AT NO ADDITIONAL COST. IF PREVIOUSLY-ISSUED |
| | COMMENTS CONTINUE TO NOT BE SUFFICIENTLY ADDRESSED, THE |
| | APPLICANT WILL BE ACCESSED A RESUBMITTAL FEE. SUCH FEE |
| | WILL BE 20% OF THE ORIGINAL APPLICATION FEE ($60). |
| | |
| | 1) PLEASE SUBMIT ALL DRAWINGS IN .PDF FORMAT. |
| | |
| | 2) PROVIDE THE DETAILS OF THE METAL AWNING. YOU MAY USE |
| | THE DETAILS FROM THE BUILDING PERMIT AS STAFF HAS |
| | REVIEWED THE PERMIT AND THE METAL AWNING IS ACCEPTABLE. |
| | PLEASE NOTE THAT THE SIGN MAY NOT BE INSTALLED ON TOP |
| | OF THE METAL AWNING, BUT IT MAY ONLY BE MOUNTED TO THE |
| | BUILDING FACADE. |
| | |
| | 3) THE NEW SIDEWALK, AS PROPOSED, ON THE EAST SIDE OF |
| | THE BUILDING INCLUDING THE ACCESSIBLE ROUTE TO THE |
| | DISABLED PARKING SPACES, IS NOT APPROVED. FULL DETAILS |
| | ON HOW THE SIDEWALK WILL FUNCTION, INCLUDING |
| | DIMENSIONS, ARE REQUIRED. ADDITIONALLY, A FULLY |
| | COMPLIANT ACCESSIBLE ROUTE, WITH DIMENSIONS, SHALL BE |
| | PROVIDED AND PLANS SHOWING SUCH SHALL BE SUBMITTED WITH |
| | THIS PERMIT. THE ROUTE INCLUDED WITH THE MINOR |
| | AMENDMENT IS NOT FULLY COMPLIANT. FURTHER, THE PLANS |
| | SUBMITTED WITH THE MINOR AMENDMENT OVERLAY THE PROPOSED |
| | ROUTE OVER THE EXISTING SURVEY. THE PLANS NEED TO SHOW |
| | THE FINAL CONFIGURATION. - THERE ARE BOLLARDS SHOWN IN |
| | THE WALK WAY AND THERE ARE PLANTERS WHICH BLOCK THE |
| | PATH THAT ARE NOT SHOWN BY THE ELEVATOR ENTRANCE DOORS. |
| | |
| | 4) THE BUILDING DIVISION REVIEWER HAS INDICATED THAT 36 |
| | INCHES IS NOT AN ADEQUATE WIDTH FOR THE ACCESSIBLE WALK |
| | WAY. PLANNING STAFF RECOMMENDS THAT THE WALK BE A |
| | MINIMUM OF SIX (6) FEET IN WIDTH TO ALLOW ADEQUATE ROOM |
| | FOR TWO PEOPLE WITH BAGS CONTAINING WORKOUT GEAR TO |
| | PASS EACH OTHER WITHOUT FORCING ONE OF THE PEOPLE INTO |
| | THE VEHICLE TRAVEL LANE. |
| | |
| | 5) THE CITY FOLLOWS FDOT LANE WIDTH STANDARDS. THE |
| | MINIMUM LANE WIDTH THAT FDOT RECOMMENDS IS 10 FEET |
| | WIDE. THE CURB TO CURB MEASURE OF THE TWO TRAVEL LANES |
| | NORTH OF THE OFFICE TOWER IS 21 FEET. ANY WALKWAY WILL |
| | REDUCE THE WIDTH OF THE AISLES TO LESS THAN 10 FEET IN |
| | WIDTH. PLEASE SHOW HOW ADEQUATE LANE WIDTH WILL BE |
| | MAINTAINED. |
| | |
| | 6) PLEASE PROVIDE HOW THE WALKWAY WILL BE LIGHTED AND |
| | WHAT ADDITIONAL SECURITY PROCEDURES WILL BE IN PLACE. |
| | THIS AREA IS ISOLATED AT NIGHT AND ON WEEKENDS WHEN THE |
| | OFFICE TOWER IS CLOSED WITH NO NATURAL SURVEILLANCE |
| | FROM INSIDE OR OUTSIDE OF CITYPLACE. |
| | |
| | 7) PLEASE NOTE THAT NOW THAT THE TRANSFORMER AREA IS A |
| | PUBLICLY ACCESSED AREA, PLEASE SHOW HOW THE MECHANICAL |
| | EQUIPMENT WILL BE SCREENED IN ACCORDANCE WITH THE |
| | REQUIREMENT FROM THE CITYPLACE DRI THAT ALL GROUND |
| | LEVEL MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED |
| | TO SUCH ITEMS AS PUBLIC AND PRIVATE UTILITY SERVICE |
| | CONNECTIONS; HEATING, VENTILATING, AND AIR CONDITIONING |
| | SYSTEMS; COMMUNICATIONS DEVICES; AND RELATED EQUIPMENT, |
| | SHALL BE SCREENED FROM PUBLIC VIEW THROUGH ANY |
| | COMBINATION OF LANDSCAPING, WALLS AND EQUIPMENT |
| | LOCATION. |
| | |
| |