| 2012-12-12 11:19:49 | CONDITIONS FOR APPROVAL |
| | PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE |
| | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY |
| | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST |
| | PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. |
| | A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION |
| | TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE |
| | SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES |
| | FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT |
| | BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, |
| | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, |
| | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE |
| | SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF |
| | WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER |
| | MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE |
| | WORKING ENVIRONMENT. |
| | B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED |
| | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. |
| | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A |
| | STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT |
| | DEVELOPMENT. |
| | C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY |
| | 500 FEET AROUND THE PERIMETER OF THE SITE. |
| | |
| | LIGHTING |
| | |
| | A. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS, |
| | BUILDING ADDRESS NUMBERS, LIGHTING AND WALKWAYS. |
| | B. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR |
| | ABOVE OR NEAR ENTRYWAYS TO RESIDENCES PROVIDE FOR DUSK |
| | TO DAWN OPERATION. |
| | NUMERICAL ADDRESS |
| | A. ILLUMINATION FOR NIGHTTIME VISIBILITY IS REQUIRED. |
| | ADDRESS SHOULD BE PLACED UNDER A LIGHT FIXTURE OR BE |
| | BACK LIT. |
| | B. ADDRESS NUMERALS SHALL BE OF A CONTRASTING COLOR TO |
| | THE BUILDING COLOR |
| | C. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS |
| | REQUIRED. |
| | D. DOOR LEADING INTO A RESIDENTIAL UNIT, INCLUDING |
| | INTERIOR SHALL BE SOLID CORE. |
| | LOCKS/MISCELLOUS |
| | A. ANTI-LIFTING AUXILIARY LOCKS SHALL BE INSTALLED ON |
| | SLIDING DOORS AND WINDOWS. |
| | B. ALL DOORS SHALL BE EQUIPPED WITH SINGLE CYLINDER |
| | DEAD BOLT LOCK WITH A MINIMUM THROW OF ONE INCH AND AN |
| | EMBEDMENT OF NOT LESS 5/8 INCH INTO THE HOLDING DEVICE. |
| | PICK PLATES SHOULD ALSO BE PLACED ALL EXTERIOR DOORS. |
| | E. STAIRWAYS SHALL PROVIDE OPEN VIEWS. |
| | F. POOL ACCESS SHALL BE RESTRICTED, BY KEY, KEY FOB, OR |
| | CARD ACCESS |
| | G. BICYCLE SPACES SHALL BE LOCATED IN CLOSE PROXIMITY |
| | TO THE FRONT OF BUILDINGS AND NOT IN PARKING LOTS. |
| | H. MAILBOX LOCATIONS SHALL BE IN A WELL LIT, HIGH |
| | TRAFFIC LOCATION. |
| | J ACCESS CONTROL SHOULD BE USED INTO THE BUILDING, THE |
| | ENTRANCE AND EXIT GATES, AND THE WALK IN GATE ON N. |
| | OLIVE. |
| | |
| | K CCTV SHOULD BE USED TO MONITOR THE PREMISES: GARAGE, |
| | POOL AREA, WALK IN GATE ON N. OLIVE, ENTRY AND EXIT |
| | GATE INTO THE COMPLEX, LOBBY, ELEVATOR/STAIRWELL |
| | ENTRANCE |
| | |
| | GARAGE |
| | |
| | A. THE EXTERIOR OF THE PARKING GARAGE SHALL BE WELL LIT |
| | ON ALL SIDES. |
| | B. CEILINGS AND SOLID WALLS IN THE PARKING GARAGE SHALL |
| | BE PAINTED WHITE TO INCREASE REFLECTIVENESS OF THE |
| | LIGHTING LUMINARIES. |
| | C. ALL LIGHTING SHALL BE VANDALISM RESISTANT. |
| | D. LIGHTING SHOULD BE PLACED WHERE USERS REQUIRE |
| | LIGHTS: OVER VEHICLES, |
| | STAIRWELLS, CCTV CAMERAS. |
| | E. LIGHTING FIXTURES SHOULD BE EXTENDED PAST THE BEAMS |
| | IN THE GARAGE CEILING |
| | |
| |