| 2012-12-04 12:23:36 | 1. PLEASE INCLUDE A TABLE AND A SCHEMATIC GRAPHIC OF |
| | EACH FLOOR INDICATING THE AREAS CALCULATED AS PART OF |
| | THE GROSS BUILDING AREA. |
| | 2. PROPOSED BUILDING IS ENCROACHING INTO THE 20' SIDE |
| | SETBACK REQUIRED ABOVE THE 5TH STORY (STAIRS). |
| | 3. PROPOSED PARKING RAMP IS ENCROACHING INTO THE FIVE |
| | FEET REQUIRED LANDSCAPE BUFFER ON THE EAST SIDE.THE |
| | VEHICULAR ACCESS IS REQUIRED TO PROVIDE A 5 FEET |
| | LANDSCAPE BUFFER. |
| | 4. TWO STORY STORAGE BUILDING SEEMS TO ENCROACH INTO |
| | THE FIVE FEET REQUIRED REAR SETBACK AT THE PARKING |
| | LEVEL. |
| | 5. RESIDENTIAL USES ARE NOT PERMITTED IN THE 1ST FLOOR. |
| | THE 2ND FLOOR WILL BE CONSIDERED ANYTHING ABOVE 5 FEET |
| | GRADE FLOOR ELEVATION. |
| | 6. PLEASE INCLUDE INFORMATION TO CONFIRM COMPLIANCE |
| | WITH THE PLANAR BREAK AND HORIZONTAL PROJECTIONS |
| | REGULATION ACCORDING TO TABLE IV-4. |
| | 7. PLEASE PROVIDE ADDITIONAL INFORMATION ON THE FIRST |
| | FLOOR PLAN TO INDICATE THE TERRACES, LOCATION OF LOW |
| | WALLS AND PLANTING AREAS IN RELATION WITH WINDOWS AND |
| | DOORS. |
| | 8. RENDER INCLUDED WITH SUBMITTAL DOES NOT ACCURATELY |
| | REFLECT THE PROPOSED FLOOR PLAN, PLEASE REVISE. |
| | 9. PLEASE INCLUDE PROPERTY LINE AND SETBACK LINE ON ALL |
| | FLOOR PLANS AND ELEVATIONS. |
| | 10. STAFF HAS CONCERNS WITH THE LOCATION OF THE BIKE |
| | PARKING. IT MAY BE DIFICULT FOR ELDERLY RESIDENTS TO |
| | RIDE THE BIKE TO THE STREET LEVEL. A LOCATION WITHIN |
| | THE FIRST FLOOR WOULD BE PREFERABLE. |
| | 11 PLEASE INCLUDE SPECS FOR THE BIKE RACK AND |
| | INSTALLATION DETAILS. |
| | 12. PLEASE SUBMIT INFORMATION REGARDING UNIT SIZE TO |
| | CONFIRM COMPLIANCE WITH MINIMUM UNIT SIZE AND AVERAGE |
| | UNIT SIZE ACCORDING TO SECTION 94-109. |
| | 13. PLEASE INCLUDE A TABLE INDICATING THE AMOUNT OF |
| | TDRS REQUIRED FOR THE PROJECT. |
| | 14. PLEASE INCLUDE INFORMATION TO CONFIRM COMPLIANCE |
| | WITH MAXIMUM BUILDING FOOTPRINT, MINIMUM ACTIVE USES |
| | AND MINIMUM TRANSPARENCY FOR ACTIVE USES (TABLE IV-44) |
| | |
| | STREETSCAPE COMMENTS: |
| | 1. STREET LIGHTING SHALL BE PROVIDED ACOORDING TO |
| | SECTION 94-113(D)(4). |
| | 2. EXISTING OVERHEAD POWERLINES SHALL BE BURIED FOR A |
| | PROJECT THIS SIZE. |
| | 3. ONCE POWER LINES ARE REMOVED STREET TREES CAN BE |
| | CHANGED TO LIVE OAKS. |
| | 4. STREETSCAPE ALONG SAPODILLA AVENUE SHALL BE CHANGED |
| | TO MEET THE EXISTING STREETSCAPE SOUTH OF EVERNIA |
| | STREET (GRASS STRIP NEXT TO THE CURB). |
| | |
| | PROCESSING COMMENTS |
| | 1. IF UTILIZING THE AFFORDABLE HOUSING INCENTIVE, THE |
| | PROJECT SHALL BE PRESENTED TO THE CITY COMMISSION FOR |
| | APPROVAL OF TDRS. PLEASE SUBMIT A FORMAL LETTER |
| | REQUESTING THE AMOUNT OF TRD NEEDED. |
| | 2. DUE TO THE APPLICATION FOR THE AFFORDABLE HOUSING |
| | INCENTIVE PROGRAM, THE PROJECT IS REQUIRED IS SUBJECT |
| | TO DAC SPECIAL REVIEW. AN APPLICATION WILL BE NECESSARY |
| | ONCE THE MAIN COMMENTS FROM PPRC ARE ADDRESSED. |
| | |
| | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA |
| | APONTE AT 561-822-1439 |
| | |
| | |
| |