| Date |
Text |
| 2012-12-12 11:26:56 | CONDITIONS FOR APPROVAL |
| | PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE |
| | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY |
| | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST |
| | PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. OFC. |
| | CARSILLO (561) 822-1620 |
| | A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION |
| | TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE |
| | SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES |
| | FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT |
| | BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, |
| | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, |
| | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE |
| | SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF |
| | WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER |
| | MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE |
| | WORKING ENVIRONMENT. |
| | B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED |
| | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. |
| | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A |
| | STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT |
| | DEVELOPMENT. |
| | C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY |
| | 500 FEET AROUND THE PERIMETER OF THE SITE. |
| | |
| | PARKING GARAGE |
| | |
| | * WILL THERE BE ACCESS CONTROLLED GATES AT THE GARAGE |
| | ENTRANCE? |
| | * BIKE PEN NEEDS TO BE WELL LIT, CCTV, OR FENCED/GATED |
| | FOR RESIDENTS ONLY |
| | |
| | A. PARKING GARAGE FIRST LEVEL SHALL HAVE RESTRICTED |
| | ACCESS FROM EXTERIOR COMMON GROUND AREA. |
| | B. GROUND LEVEL PEDESTRIAN EXITS THAT OPEN INTO |
| | NON-SECURE AREAS SHALL BE EMERGENCY EXITS ONLY AND |
| | FITTED WITH PANIC BAR HARDWARE. |
| | C. CENTER OF THE GARAGE SHALL HAVE CONNECTIVITY TO ALL |
| | CROSSWALKS. |
| | D. DIRECTIONAL ARROWS AND SIGNAGE INDICATING EXITS, |
| | STAIRS, AND ELEVATORS SHALL BE PROVIDED. |
| | E. PEDESTRIAN ENTRANCES SHALL BE ADJACENT TO VEHICLE |
| | ENTRANCES, OPEN AND FREE OF HIDDEN SPACES AND WIRED FOR |
| | CCTV SURVEILLANCE. |
| | F. PUBLIC AND PRIVATE PARKING SPACES SHALL BE |
| | DESIGNATED. |
| | G. WALLS AND SUPPORT STRUCTURES SHALL ALL BE |
| | CONSTRUCTED WITH OPEN SIDES TO AVOID CREATION OF HIDDEN |
| | SPACES. |
| | H. ACCESS POINTS TO THE FACILITY SHALL BE MINIMIZED. |
| | I. CEILINGS AND SOLID WALLS IN THE PARKING GARAGE SHALL |
| | BE PAINTED WHITE TO INCREASE BRIGHTNESS WITHIN THE |
| | FACILITY. |
| | J. CONVEX MIRRORS SHALL BE INSTALLED IN STAIRWELL AND |
| | ELEVATOR AREAS. |
| | K. UTILIZE SECURITY VISION DOORS AT ENTRANCE TO |
| | STAIRWELLS ON EACH FLOOR. |
| | L. STAIRWELLS SHOULD BE WELL LIT OR HAVE AN OPEN DESIGN |
| | M. LIGHTING SHOULD BE PLACED WHERE USERS REQUIRE |
| | LIGHTS: OVER VEHICLES, STAIRWELLS, CCTVCAMERAS. |
| | N. LIGHTING FIXTURES SHOULD BE EXTENDED PAST THE BEAMS |
| | IN THE GARAGE CEILING |
| | |
| | |
| | |
| | |
| | ADDRESSING/ APARTMENT SECURITY |
| | |
| | * WILL THE LOBBY BE MANNED? IF NO THERE WILL NEED TO BE |
| | ACCESS CONTROL INTO THE BUILDING FROM THE STREET AND |
| | FROM THE PARKING GARAGE. (ELEVATOR, DOORS, STAIRWELLS) |
| | * POOL WILL NEED ACCESS CONTROL FOR RESIDENTS ONLY, |
| | CCTV, BACK STAIRS LEADING UP TO THE POOL AREA FROM THE |
| | STREET WILL BE GATED WITH ACCESS CONTROL. |
| | * THE CARD ROOM, MAIL ROOM, EXERCISE ROOM AND WORKROOM |
| | SHALL HAVE WINDOWS THAT LOOK OUT INTO THE MAIN FLOOR. |
| | * LAUNDRY ROOM, ACCESS CONTROL FOR EMPLOYEES ONLY |
| | |
| | A. ILLUMINATION FOR NIGHTTIME VISIBILITY IS REQUIRED. |
| | ADDRESS SHOULD BE PLACED UNDER A LIGHT FIXTURE OR BE |
| | BACK LIT. |
| | B. ADDRESS NUMERALS SHALL BE OF A CONTRASTING COLOR TO |
| | THE BUILDING COLOR |
| | C. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS |
| | REQUIRED. |
| | D. DOOR LEADING INTO A RESIDENTIAL UNIT, SHALL BE SOLID |
| | CORE. |
| | E. EXTERIOR DOORS SHALL BE EQUIPPED WITH A 180-DEGREE |
| | PEEPHOLE AND NON-REMOVABLE SECURITY HINGES. |
| | H. ANTI-LIFTING AUXILIARY LOCKS SHALL BE INSTALLED ON |
| | SLIDING DOORS AND WINDOWS. |
| | I. ALL DOORS SHALL BE EQUIPPED WITH SINGLE CYLINDER |
| | DEAD BOLT LOCK WITH A MINIMUM THROW OF ONE INCH AND AN |
| | EMBEDMENT OF NOT LESS 5/8 INCH INTO THE HOLDING DEVICE. |
| | PICK PLATES SHOULD ALSO BE PLACED ALL EXTERIOR DOORS. |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| |
Print |