Plan Review Notes For Project Z12110016
Project Number Z12110016
Review Stop STORM
Sequence Number 3
Notes
Date Text
2013-07-23 20:35:531. SUBMIT DRAINAGE CALCULATIONS WITH ENGINEERING PERMIT
 APPLICATION. WATER QUALITY TREATMENT TO BE PROVIDED PER
 SFWMD CRITERIA.
 2. CONFIRM NO CONFLICT BETWEEN EXISTING 10" WATER MAIN
 AND PROPOSED 18" RCP IN HIBISCUS STREET R/W.
 3. USE RCP PIPE WITHIN R/W (OUTFALL PIPE FROM STRUCTURE
 NO. 4).
 4. CONFIRM NO CONFLICT BETWEEN PROPOSED 15" OUTFALL
 PIPE FROM STRUCTURE NO. 4 AND THE EXISTING GAS PIPE.
 5. CONFIRM CAR PARKED IN H.C. RAMP AT HOTEL ONSITE
 PARKING LOT CAN BACK OUT TO THE EAST INTO 20' DRIVE
 AISLE.
  
 TRACY L. WARD, P.E.
 SENIOR STORM WATER ENGINEER
 ENGINEERING AND PUBLIC WORKS DEPARTMENT