Plan Review Notes
Plan Review Notes For Project Z12110016
Project Number Z12110016
Review Stop Z
Sequence Number 1
Notes
Date Text
2012-12-11 09:00:01BUILDING REQUIREMENTS COMMENTS:
 - PLEASE MODIFY THE BUILDIGN DATA TO INCLUDE TOTAL SITE
 AREA, GROSS BUILDING AREA, AND MECHANICAL AREA. INCLUDE
 A GRAPHIC OF EACH FLOOR INDICATING AREAS COUNTED AS
 GROSS BUILDING AREA, AND MECHANICAL (SEE DEFINITION IN
 SEC 94-109)
 - PLEASE CONFIRM COMPLIANCE WITH MAXIMUM BUILDING
 FOOTPRINT.
 - PLEASE CONFIRM COMPLIANCE WITH FIVE FEET REAR
 SETBACK.
 - PLEASE CONFIRM COMPLIANCE WITH 20 FEET SIDE SETBACK
 ABOVE 5TH STORY. EAST STAIR ENCROACHING INTO SETBACK.
 - PLEASE INDICATE ON A GRAPHIC WHICH AREAS ARE BEING
 CONTED FOR THE PRIVATE OPEN SPACE, INCLUDE AREAS AND
 CONFIRM COMPLIANCE WITH OPEN SPACE REQUIREMENTS
 ACOORDING TO TABLE IV-7 AND IV-8.
 - SURVEY INDICATES A DIFFERENT LOCATION FOR EXISTING
 - OFF SITE PARKING EXIT/ENTRANCE CIRCULATION SHALL BE
 STUDY DUE TO POSSIBLE SAFETY CONFLICTS. PLESE PROVIDE A
 CIRCULATION AND OPERATION STUDY FOR THE DROP-OFF/VALET
 AREA AND PARKING.
 - PROPOSED PORTE-COCHERE TYPE "A" DOES NOT COMPLY WITH
 THE REQUIRED DIMENSIONS. A DAC VARIANCE WILL BE
 NECESSARY DUE TO ITS COMBINATION WITH THE PARKING
 ACCESS DRIVE.
 - TREE ALTERATION PERMIT SHALL BE MODIFIED ACCORDING TO
 NEW LANDSCAPE PLANT.
 - OPEN SPACE AREA CANNOT INCLUDE COVERED AREAS. OPEN
 SPACE IS DEFINED AS AN IMPROVED OUTDOOR AREA OPEN TO
 THE SKY.
 - PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE WITH
 THE MINIMUM 50% TRANSPARENCY REQUIREMENT ALONG THE 1ST
 FLOOR OF HIBISCUS STREET.
 - PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE WITH
 FACADE ARTICULATION REQUIREMENTS ACCORDING TO TABLE
 IV-4.
 - PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE WITH
 MINIMUM 65% ACTIVE USE REQUIREMENTS. MECHANICAL
 ROOMS/STORAGE ROOMS ARE NOT CONSIDERED ACTIVE USE.
 - ALL MECHANICAL EQUIPMENT ON ROOFTOP SHALL BE ENCLOSED
 AND SCREENED.
 - COLOR ELEVATIONS AND RENDERS INDICATING THE BUILDING
 SETTING IN ITS CONTEXT ARE NECESSARY FOR THE DAC
 SPECIAL REVIEW.
  
 STREETSCAPE:
 - PLEASE CLARIFY THE IMPACT ON THE PEDESTRIAN PATH OF
 THE UTILITY CONNECTION (DOMESTRIC METER VAULT) LOCATED
 WITHIN THE REQUIRED SETBACK ALONG HIBISCUS ST.
 - FURTHER DISCUSSION WILL BE NECESSARY WITH STAFF TO
 COORDINATE THE EXACT CONFIGURATION OF THE CURB AND THE
 SELECTION FOR PLANT MATERIAL. IT SEEMS PROPOSED PROJECT
 IS MOVING THE CURB TOWARDS THE CENTER OF THE ROAD.
  
 OFF SITE PARKING:
 - OFF SITE PARKING WILL REQUIRE DAC APPROVAL
 - SURFACE PARKING LOTS REQUIRE A FIVE FEET LANDSCAPE
 BUFFER AROUNG THE ENTIRE SURFACE PARKING LOT.
 - FIVE FEET TREE ISLANDS ARE REQUIRED EVERY 10 PARKING
 SPACES.
 - ACCESS SHALL BE PROVIDED THROUGH GARDENIA STREET.
 - A TREE ALTERATION PERMIT FOR THE NEW SURFACE PARKING
 LOT SHALL BE SUBMITTED.
 - DEMOLITION OF EXISTING BUILDING IS NOT PERMITTED
 UNDER THE CURRENT DMP REGULATIONS. DAC APPROVAL FOR
 DEMOLITION WILL BE NECESSARY.
 - SURFACE PARKING LOTS ALONG PRIMARY STREETS ARE NOT
 PERMITTED, DIXIE HWAY IS A PRIMARY STREET.
 - WHEEL STOPS ARE REQUIRED FOR ALL PARKING SPACES.
  
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.