| Date |
Text |
| 2012-11-14 10:51:19 | BUILDING REVIEW COMMENTS |
| | |
| | |
| | PRELIMINARY PLANS LOOK GOOD FOR NOW. |
| | |
| | A THRESHOLD INSPECTOR WILL BE REQUIRE FOR THIS PROJECT. |
| | |
| | |
| | |
| | LUIS MARTINEZ |
| | 561-805-6710 |
| | |
| | |
| | |
| | |
| 2012-11-13 15:59:42 | I SEE THE LIGHTING AROUND THE BUILDINGS, WHAT LIGHTING |
| | WILL IN BETWEEN THE BUILDINGS? |
| | ACCESS CONTROL SHOULD BE USED TO THE CLUBHOUSE AND THE |
| | FITNESS BLDG |
| | WILL THERE BE A PLAYGROUND? POOL? IF SO I WILL WANT TO |
| | SEE THE PLANS FOR THAT |
| | MAIL BOX AREA? |
| | WILL THE ENTRY/EXIT GATE HAVE CAMERA COVERAGE? |
| | BIKE RACKS? |
| | CONDITIONS FOR APPROVAL |
| | PRIOR TO ISSUANCE OF THE FIRST BUILDING PERMIT, THE |
| | APPLICANT SHALL PREPARE A CONSTRUCTION SITE SECURITY |
| | AND MANAGEMENT PLAN FOR APPROVAL BY THE CITY OF WEST |
| | PALM BEACH POLICE DEPARTMENT CPTED OFFICIAL. |
| | A. AFTER SITE CLEARING AND PLACEMENT OF CONSTRUCTION |
| | TRAILERS, THE DEVELOPER/PROJECT MANAGER SHALL INSTITUTE |
| | SECURITY MEASURES TO REDUCE OR ELIMINATE OPPORTUNITIES |
| | FOR THEFT. THE MANAGEMENT PLAN SHALL INCLUDE, BUT NOT |
| | BE LIMITED TO, TEMPORARY LIGHTING, SECURITY PERSONNEL, |
| | VEHICLE BARRIERS, CONSTRUCTION/VISITOR PASS, |
| | REDUCE/MINIMIZE ENTRY/EXIT POINTS, ENCOURAGE |
| | SUBCONTRACTORS TO SECURE MACHINERY, TOOLS AT END OF |
| | WORK DAY, FENCING WITH SCREENING AND OR ANY OTHER |
| | MEASURE DEEMED APPROPRIATE TO PROVIDE A SAFE AND SECURE |
| | WORKING ENVIRONMENT. |
| | B. THE SECURITY MANAGEMENT PLAN SHALL BE MAINTAINED |
| | THROUGHOUT THE CONSTRUCTION PHASE OF THE PROJECT. |
| | NON-COMPLIANCE WITH THE APPROVED PLAN SHALL RESULT IN A |
| | STOP-WORK ORDER FOR THE ENTIRE PLANNED UNIT |
| | DEVELOPMENT. |
| | C. PROPERTY SHALL BE POST ?NO TRESPASSING? SIGNS EVERY |
| | 500 FEET AROUND THE PERIMETER OF THE SITE. |
| | LIGHTING |
| | A. LANDSCAPING SHALL NOT OBSTRUCT VIEW OF WINDOWS, |
| | BUILDING ADDRESS NUMBERS, LIGHTING AND WALKWAYS. |
| | B. TIMER CLOCK OR PHOTOCELL SENSOR-ENGAGED LIGHTING FOR |
| | ABOVE OR NEAR ENTRYWAYS TO RESIDENCES PROVIDE FOR DUSK |
| | TO DAWN OPERATION. |
| | C. ENTRANCE SIGN LIGHTING SHALL BE PROVIDED. DIRECTORY |
| | SHOULD BE AT ALL ENTRANCES WITH LIGHTING. |
| | D. BUILDING LIGHTING (NON GLARE) SHALL BE AROUND |
| | PERIMETER ON ALL SIDES. |
| | NUMERICAL ADDRESS |
| | A. ILLUMINATION FOR NIGHTTIME VISIBILITY IS REQUIRED. |
| | ADDRESS SHOULD BE PLACED UNDER A LIGHT FIXTURE OR BE |
| | BACK LIT. |
| | B. ADDRESS NUMERALS SHALL BE OF A CONTRASTING COLOR TO |
| | THE BUILDING COLOR |
| | C. BI-DIRECTIONAL VISIBILITY FROM THE ROADWAY IS |
| | REQUIRED. |
| | D. ADDRESS NUMBERS ON DOORS OF MULTI-UNITS AND SINGLE |
| | FAMILY HOMES NEED TO BE A MINIMUM OF 6 INCHES HIGH. |
| | E. BUILDING NUMBERS FOR MULTI-UNIT BUILDINGS SHALL BE A |
| | MINIMUM OF 12 INCHES HIGH AND PLACED IN A CONSPICUOUS |
| | LOCATION ON ALL SIDES WITH PUBLIC ACCESS, AWAY FROM |
| | LANDSCAPING. NUMBERS SHOULD BE OF A CONTRASTING |
| | BACKGROUND. |
| | DOORS |
| | A. DOOR LEADING INTO A RESIDENTIAL UNIT, INCLUDING |
| | INTERIOR GARAGE SHALL BE SOLID CORE. |
| | B. EXTERIOR DOORS SHALL BE EQUIPPED WITH A 180-DEGREE |
| | PEEPHOLE AND NON-REMOVABLE SECURITY HINGES. |
| | LOCKS |
| | A. ANTI-LIFTING AUXILIARY LOCKS SHALL BE INSTALLED ON |
| | SLIDING DOORS AND WINDOWS. |
| | B. ALL DOORS SHALL BE EQUIPPED WITH SINGLE CYLINDER |
| | DEAD BOLT LOCK WITH A MINIMUM THROW OF ONE INCH AND AN |
| | EMBEDMENT OF NOT LESS 5/8 INCH INTO THE HOLDING DEVICE. |
| | PICK PLATES SHOULD ALSO BE PLACED ALL EXTERIOR DOORS. |
| | MISCELLANEOUS |
| | A. STAIRWAYS (TO INCLUDE RISERS/BANISTERS) |
| | B. SALES CENTER, CLUBHOUSE AND RECREATIONAL FACILITIES |
| | SHALL BE PRE-WIRED TO ALARM CENTER. |
| | C. RECREATION BUILDING AND POOL ACCESS SHALL BE |
| | RESTRICTED, BY KEY, KEY FOB, OR CARD ACCESS |
| | D. BICYCLE SPACES SHALL BE LOCATED IN CLOSE PROXIMITY |
| | TO THE FRONT OF BUILDINGS AND NOT IN PARKING LOTS. |
| | E. MAILBOX LOCATIONS SHALL BE IN A WELL LIT, HIGH |
| | TRAFFIC LOCATION. |
| | |
| | |
| |
Print |